Lance O'Hari Go

Dr. Lance O'Hari Go

Ateneo de Manila University
+1
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Analytica Chimica Acta
Verified
Journal Article
Closed access
Sarah May Sibug-TorresSarah May Sibug-Torres
Sarah May Sibug-Torres
LGLance O'Hari Go
Lance O'Hari Go
VCVirgil Christian G. Castillo
Virgil Christian G. Castillo
JPJiena Lynne R. Pauco
Jiena Lynne R. Pauco
EEErwin P. Enriquez
Erwin P. Enriquez

7 February 2018 in ACS Applied Nano Materials
Verified
Journal Article
Closed access
NBNikita Bacalzo
Nikita Bacalzo
LGLance O'Hari Go
Lance O'Hari Go
Christine Joy QuerebilloChristine Joy Querebillo
Christine Joy Querebillo
PHPeter Hildebrandt
Peter Hildebrandt
FLF. T. Limpoco
F. T. Limpoco
EEErwin P. Enriquez
Erwin P. Enriquez

13 December 2020 in Chemosensors
Verified
Journal Article
Open access
PDF file
Sarah May Sibug-TorresSarah May Sibug-Torres
Sarah May Sibug-Torres
LGLance O'Hari Go
Lance O'Hari Go
EEErwin P. Enriquez
Erwin P. Enriquez
Fused filament fabrication (FFF) is a 3D printing method that is attracting increased interest in the development of miniaturized electrochemical sensor systems due to its versatility, low cost, reproducibility, and capability for rapid prototyping. A key component of miniaturized electrochemical systems is the reference electrode (RE). However, reports of the fabrication of a true 3D-printed RE that exhibits stability to variations in the sample matrix remain limited. In this work, we report the development and characterization of a 3D-printed Ag|AgCl|gel-KCl reference electrode (3D-RE). The RE was constructed using a Ag|AgCl wire and agar-KCl layer housed in a watertight 3D-printed acrylonitrile butadiene styrene (ABS) casing. The novel feature of our electrode is a 3D-printed porous junction that protects the gel electrolyte layer from chloride ion leakage and test sample contamination while maintaining electrical contact with the sample solution. By tuning the 3D printing filament extrusion ratio (k), the porosity of the junction was adjusted to balance the reference electrode potential stability and impedance. The resulting 3D-RE demonstrated a stable potential, with a potential drift of 4.55 ± 0.46 mV over a 12-h period of continuous immersion in 0.1 M KCl, and a low impedance of 0.50 ± 0.11 kΩ. The 3D-RE was also insensitive to variations in the sample matrix and maintained a stable potential for at least 30 days under proper storage in 3 M KCl. We demonstrate the application of this 3D-RE in cyclic voltammetry and in pH sensing coupled with electrodeposited iridium oxide on a gold electrode. Our method offers a viable strategy for 3D printing a customizable true reference electrode that can be readily fabricated on demand and integrated into 3D-printed miniaturized electrochemical sensor systems.

7 February 2024 in Polymers
Verified
Journal Article
Open access
PDF file
LGLance O'Hari Go
Lance O'Hari Go
MSMohamed Mehawed Abdellatif Soliman
Mohamed Mehawed Abdellatif Soliman
RMRyoji Makino
Ryoji Makino
DSDaisuke Shimoyama
Daisuke Shimoyama
SHSeiji Higashi
Seiji Higashi
Kotohiro NomuraKotohiro Nomura
Kotohiro Nomura
Development of biobased aliphatic polyesters with better mechanical (tensile) properties in film has attracted considerable attention. This report presents the synthesis of soluble network biobased aliphatic polyesters by acyclic diene metathesis (ADMET) polymerization of bis(undec-10-enyl)isosorbide diester [M1, dianhydro-D-glucityl bis(undec-10-enoate)] in the presence of a tri-arm crosslinker [CL, glycerol tris(undec-10-enoate)] using a ruthenium–carbene catalyst, and subsequent olefin hydrogenation using RhCl(PPh3)3. The resultant polymers, after hydrogenation (expressed as HCP1) and prepared in the presence of 1.0 mol% CL, showed better tensile properties than the linear polymer (HP1) with similar molecular weight [tensile strength (elongation at break): 20.8 MPa (282%) in HP1 vs. 35.4 MPa (572%) in HCP1]. It turned out that the polymer films prepared by the addition of CL during the polymerization (expressed as a 2-step approach) showed better tensile properties. The resultant polymer film also shows better tensile properties than the conventional polyolefins such as linear high density polyethylene, polypropylene, and low density polyethylene.

10 February 2020 in Bulletin of Materials Science
Verified
Journal Article
Closed access
PDF file
LGLance O'Hari Go
Lance O'Hari Go
LML Macaraig
L Macaraig
EEE Enriquez
E Enriquez

1 May 2019 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
LGLance O'Hari Go
Lance O'Hari Go
EEErwin Paredes Enriquez
Erwin Paredes Enriquez
Inkjet printing has been gaining widespread application in printed electronics research. However, there are certain metals that cannot be printed easily without being oxidized in ambient air during post-print processing. One such example that has been thoroughly researched is sintering of printed copper nanoparticles or copper salts, which gets oxidized when exposed to sintering temperature in the presence of oxygen in air. There have been successful examples of workaround for printing copper inks. However, metals that are more reactive than copper, in terms of the activity series, is going to be a challenge to print and anneal. In such a case, we explore the use of electrodeposition, another well-established additive manufacturing technology. This study investigates the use of electrodeposition of zinc metal on inkjet-printed silver seed layer for use in printed electronic applications where the chemistry of zinc is desirable, such as in galvanic dissolved-oxygen (DO) sensors. There are a couple of literature that demonstrate inkjet-printed polarographic DO sensors using silver anode and gold cathode. However, commercial polarographic DO sensors do require more frequent maintenance compared to commercial galvanic DO sensors due to tarnishing of the gold cathode, which then requires physical polishing. In the case of galvanic DO sensors, the zinc hydroxide/ zinc oxide that results from oxidation of zinc anode is porous and thus flakes off by itself requiring less maintenance. Another advantage of a galvanic DO sensor is that the dissolved oxygen is directly measured as a potential between the anode and cathode, whereas a polarographic sensor requires an external potential sweep between the anode and cathode to measure the current produced by the sensor. This necessitates a slightly more complex measuring equipment and a longer scan time for polarographic DO sensors. The sensor was fabricated as such. Silver ink (Silverjet DGP 40LT-15C) electrodes (final silver cathode and anode seed layer), conducting wires, and contact pads were inkjet printed on flexible PEN substrate (150 microns, Dupont Teijin PQA1) followed by annealing at 180oC. The silver seed layer for the anode was then electrodeposited with zinc using zinc acetate dihydrate (Sigma-Aldrich ACS reagent, >99.0%) electroplating solution and zinc plate anode (acquired from Panasonic size D Zinc-Carbon battery). XRD pattern of printed silver coincides with diffraction peaks of face-centered cubic silver (JCPDS PDF # 01-087-0720), while XRD pattern of electrodeposited zinc matches with diffraction peaks of hexagonal zinc (JCPDS PDF # 00-004-0831). Preliminary devices have shown issues such as delamination of silver seed layer during zinc plating, or curling of electroplated zinc layer during galvanic operation. This was addressed by anchoring the silver seed layer to the PEN substrate by inkjet printing PMMA layer (Sigma-Aldrich 15,000 Mw PMMA; dissolved in NMP solvent at 15% wt/wt) prior to electrodeposition of zinc. In addition, PMMA ink was printed over the silver conducting wires to act as an insulator. Immersing the electrodes (both 2.0mm x 1.5mm in dimension) in 0.5M KOH electrolyte solution results in a galvanic micro-battery which yields an open circuit voltage of 1.43 V and short circuit current of 1.5 µA. Lastly, we show a proof-of-concept galvanic dissolved oxygen probe using the electrodeposited zinc anode, inkjet printed silver cathode, 0.5 M KOH as the electrolyte, PTFE membrane (Hannah DO screw cap membrane; product # HI76407A/P) as the gas permeable membrane, and bonded acrylic sheets as water tight housing. This device has an output voltage of 62.5 mV when calibrated in saturated 100% humidified air and a voltage of 0.3 mV when calibrated in 0% calibration solution (Atlas Scientific DO test solution; part # CHEM-DO). This is comparable to the working potential of a commercially available galvanic DO probe (Atlas Scientific Dissolved Oxygen probe, part # ENV-40-DO), which puts out 61.8 mV when saturated with air and 0.9 mV in 0% calibration solution. Figure 1