Giulia Buizza

Ms. Giulia Buizza

Politecnico di Milano - Department of Electronics, Information and Bioengineering
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2020 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
CKChristopher Kurz
Christopher Kurz
GBGiulia Buizza
Giulia Buizza
GLGuillaume Landry
Guillaume Landry
FKFlorian Kamp
Florian Kamp
MRMoritz Rabe
Moritz Rabe
MRMarco Riboldi
Marco Riboldi
The integration of magnetic resonance imaging (MRI) for guidance in external beam radiotherapy has faced significant research and development efforts in recent years. The current availability of linear accelerators with an embedded MRI unit, providing volumetric imaging at excellent soft tissue contrast, is expected to provide novel possibilities in the implementation of image-guided adaptive radiotherapy (IGART) protocols. This study reviews open medical physics issues in MR-guided radiotherapy (MRgRT) implementation, with a focus on current approaches and on the potential for innovation in IGART.Daily imaging in MRgRT provides the ability to visualize the static anatomy, to capture internal tumor motion and to extract quantitative image features for treatment verification and monitoring. Those capabilities enable the use of treatment adaptation, with potential benefits in terms of personalized medicine. The use of online MRI requires dedicated efforts to perform accurate dose measurements and calculations, due to the presence of magnetic fields. Likewise, MRgRT requires dedicated quality assurance (QA) protocols for safe clinical implementation.Reaction to anatomical changes in MRgRT, as visualized on daily images, demands for treatment adaptation concepts, with stringent requirements in terms of fast and accurate validation before the treatment fraction can be delivered. This entails specific challenges in terms of treatment workflow optimization, QA, and verification of the expected delivered dose while the patient is in treatment position. Those challenges require specialized medical physics developments towards the aim of fully exploiting MRI capabilities. Conversely, the use of MRgRT allows for higher confidence in tumor targeting and organs-at-risk (OAR) sparing.The systematic use of MRgRT brings the possibility of leveraging IGART methods for the optimization of tumor targeting and quantitative treatment verification. Although several challenges exist, the intrinsic benefits of MRgRT will provide a deeper understanding of dose delivery effects on an individual basis, with the potential for further treatment personalization.

18 January 2021 in Cancers
Verified
Journal Article
Open access
PDF file
GBGiulia Buizza
Giulia Buizza
CPChiara Paganelli
Chiara Paganelli
EDEmma D’ippolito
Emma D’ippolito
GFGiulia Fontana
Giulia Fontana
SMSilvia Molinelli
Silvia Molinelli
GBGuido Baroni
Guido Baroni
Skull-base chordoma (SBC) can be treated with carbon ion radiotherapy (CIRT) to improve local control (LC). The study aimed to explore the role of multi-parametric radiomic, dosiomic and clinical features as prognostic factors for LC in SBC patients undergoing CIRT. Before CIRT, 57 patients underwent MR and CT imaging, from which tumour contours and dose maps were obtained. MRI and CT-based radiomic, and dosiomic features were selected and fed to two survival models, singularly or by combining them with clinical factors. Adverse LC was given by in-field recurrence or tumour progression. The dataset was split in development and test sets and the models’ performance evaluated using the concordance index (C-index). Patients were then assigned a low- or high-risk score. Survival curves were estimated, and risk groups compared through log-rank tests (after Bonferroni correction α = 0.0083). The best performing models were built on features describing tumour shape and dosiomic heterogeneity (median/interquartile range validation C-index: 0.80/024 and 0.79/0.26), followed by combined (0.73/0.30 and 0.75/0.27) and CT-based models (0.77/0.24 and 0.64/0.28). Dosiomic and combined models could consistently stratify patients in two significantly different groups. Dosiomic and multi-parametric radiomic features showed to be promising prognostic factors for LC in SBC treated with CIRT.

1 April 2019 in Physica Medica
Verified
Journal Article
Closed access
MAMehdi Astaraki
Mehdi Astaraki
CWChunliang Wang
Chunliang Wang
GBGiulia Buizza
Giulia Buizza
ITIuliana Toma-Dasu
Iuliana Toma-Dasu
MLMarta Lazzeroni
Marta Lazzeroni
ÖSÖrjan Smedby
Örjan Smedby

1 October 2018 in Physica Medica
Verified
Journal Article
Closed access
GBGiulia Buizza
Giulia Buizza
ITIuliana Toma-Dasu
Iuliana Toma-Dasu
MLMarta Lazzeroni
Marta Lazzeroni
CPChiara Paganelli
Chiara Paganelli
MRMarco Riboldi
Marco Riboldi
CWChunliang Wang
Chunliang Wang

1 September 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
CPChiara Paganelli
Chiara Paganelli
SPS Portoso
S Portoso
NGN Garau
N Garau
GMG Meschini
G Meschini
RVR Via
R Via
GBG Baroni
G Baroni
MRI-treatment units enable 2D cine-MRI centred in the tumour for motion detection in radiotherapy, but they lack 3D information due to spatio-temporal limits. To derive time-resolved 3D information, different approaches have been proposed in the literature, but a rigorous comparison among these strategies has not yet been performed. The goal of this study is to quantitatively investigate five published strategies that derive time-resolved volumetric MRI in MRI-guided radiotherapy: Propagation, out-of-plane motion compensation, Fayad model, ROI-based model and Stemkens model. Comparisons were performed using an MRI digital phantom generated with six different patient-derived motion signals and tumour-shapes. An average 4D cycle was generated as well as 2D cine-MRI data with corresponding 3D in-room ground truth. Quantitative analysis was performed by comparing the estimated 3D volume to the ground truth available for each 2D cine-MRI sample. A grouped patient statistical analysis was performed to evaluate the performance of the selected methods, in case of tumour tracking or motion estimation of the whole anatomy. Analyses were also performed based on patient characteristics. Quantitative ranking of the investigated methods highlighted that Propagation and ROI-based model strategies achieved an overall median tumour centre of mass 3D distance from the ground truth of 1.1 mm and 1.3 mm, respectively, and a diaphragm distance below 1.6 mm. Higher errors and variabilities were instead obtained for other methods, which lack the ability to compensate for in-room variations and to account for regional changes. These results were especially evident when further analysing patient characteristics, where errors above 2 mm/5 mm in tumour/diaphragm were found for more irregular breathing patterns in case of out-of-plane motion compensation, Fayad and Stemkens models. These findings suggest the potential of the proposed in silico framework to develop and compare strategies to estimate time-resolved 3DMRI in MRI-guided radiotherapy.

29 January 2024 in Chest
Verified
Journal Article
Open access
JRJan Rudolph
Jan Rudolph
CHChristian Huemmer
Christian Huemmer
APAlexander Preuhs
Alexander Preuhs
GBGiulia Buizza
Giulia Buizza
BHBoj F. Hoppe
Boj F. Hoppe
BSBastian O. Sabel
Bastian O. Sabel
Chest radiographs (CXRs) are still of crucial importance in primary diagnostics, but their interpretation poses difficulties at times. Can a convolutional neural network-based artificial intelligence (AI) system that interprets CXRs add value in an emergency unit setting? A total of 563 CXRs acquired in the emergency unit of a major university hospital were retrospectively assessed twice by three board-certified radiologists, three radiology residents, and three emergency unit-experienced nonradiology residents (NRRs). They used a two-step reading process: (1) without AI support; and (2) with AI support providing additional images with AI overlays. Suspicion of four suspected pathologies (pleural effusion, pneumothorax, consolidations suspicious for pneumonia, and nodules) was reported on a five-point confidence scale. Confidence scores of the board-certified radiologists were converted into four binary reference standards of different sensitivities. Performance by radiology residents and NRRs without AI support/with AI support were statistically compared by using receiver-operating characteristics (ROCs), Youden statistics, and operating point metrics derived from fitted ROC curves. NRRs could significantly improve performance, sensitivity, and accuracy with AI support in all four pathologies tested. In the most sensitive reference standard (reference standard IV), NRR consensus improved the area under the ROC curve (mean, 95% CI) in the detection of the time-critical pathology pneumothorax from 0.846 (0.785-0.907) without AI support to 0.974 (0.947-1.000) with AI support (P < .001), which represented a gain of 30% in sensitivity and 2% in accuracy (while maintaining an optimized specificity). The most pronounced effect was observed in nodule detection, with NRR with AI support improving sensitivity by 53% and accuracy by 7% (area under the ROC curve without AI support, 0.723 [0.661-0.785]; with AI support, 0.890 [0.848-0.931]; P < .001). Radiology residents had smaller, mostly nonsignificant gains in performance, sensitivity, and accuracy with AI support. We found that in an emergency unit setting without 24/7 radiology coverage, the presented AI solution features an excellent clinical support tool to nonradiologists, similar to a second reader, and allows for a more accurate primary diagnosis and thus earlier therapy initiation.