Sally A. Peyman

Dr. Sally A. Peyman

School of Physics and Astronomy, University of Leeds, Leeds LS2 9JT, UK
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2020 in Medical Microbiology and Immunology
Verified
Journal Article
Open access
PDF file
JLJuan Leva
Juan Leva
SPSally A. Peyman
Sally A. Peyman
PMPaul Millner
Paul Millner
Since the discovery of antibiotics in the first quarter of the twentieth century, their use has been the principal approach to treat bacterial infection. Modernized medicine such as cancer therapy, organ transplantation or advanced major surgeries require effective antibiotics to manage bacterial infections. However, the irresponsible use of antibiotics along with the lack of development has led to the emergence of antimicrobial resistance which is considered a serious global threat due to the rise of multidrug-resistant bacteria (Wang et al. in Antibiotic resistance: a rundown of a global crisis, pp. 1645–1658, 2018). Currently employed diagnostics techniques are microscopy, colony counting, ELISA, PCR, RT-PCR, surface-enhanced Raman scattering and others. These techniques provide satisfactory selectivity and sensitivity (Joung et al. in Sens Actuators B Chem 161:824–831, 2012). Nevertheless, they demand specialized personnel and expensive and sophisticated machinery which can be labour-intensive and time-consuming, (Malvano et al. in Sensors (Switzerland) 18:1–11, 2018; Mantzila et al. in Anal Chem 80:1169–1175, 2008). To get around these problems, new technologies such as biosensing and lab-on-a-chip devices have emerged in the last two decades. Impedimetric immunosensors function by applying electrochemical impedance spectroscopy to a biosensor platform using antibodies or other affinity proteins such as Affimers (Tiede et al. in Elife 6(c):1–35, 2017) or other binding proteins (Weiss et al. in Electrochim Acta 50:4248–4256, 2005) as bioreceptors, which provide excellent sensitivity and selectivity. Pre-enrichment steps are not required and this allows miniaturization and low-cost. In this review different types of impedimetric immunosensors are reported according to the type of electrode and their base layer materials, either self-assembled monolayers or polymeric layers, composition and functionalization for different types of bacteria, viruses, fungi and disease biomarkers. Additionally, novel protein scaffolds, both antibody derived and non-antibody derived, used to specifically target the analyte are considered.

1 December 2009 in Journal of Chromatography A
Verified
Journal Article
Closed access
SPSally A. Peyman
Sally A. Peyman
EKEr Yee Kwan
Er Yee Kwan
OMOliver Margarson
Oliver Margarson
AIAlexander Iles
Alexander Iles
Nicole PammeNicole Pamme
Nicole Pamme

21 August 2009 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SPSally A. Peyman
Sally A. Peyman
AIAlexander Iles
Alexander Iles
Nicole PammeNicole Pamme
Nicole Pamme
An extremely versatile microfluidic device is demonstrated in which multi-step (bio)chemical procedures can be performed in continuous flow. The system operates by generating several co-laminar flow streams, which contain reagents for specific (bio)reactions across a rectangular reaction chamber. Functionalised magnetic microparticles are employed as mobile solid-supports and are pulled from one side of the reaction chamber to the other by use of an external magnetic field. As the particles traverse the co-laminar reagent streams, binding and washing steps are performed on their surface in one operation in continuous flow. The applicability of the platform was first demonstrated by performing a proof-of-principle binding assay between streptavidin coated magnetic particles and biotin in free solution with a limit of detection of 20 ng mL−1 of free biotin. The system was then applied to a mouse IgG sandwich immunoassay as a first example of a process involving two binding steps and two washing steps, all performed within 60 s, a fraction of the time required for conventional testing.

29 August 2012 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SPSally A. Peyman
Sally A. Peyman
RARadwa H. Abou-Saleh
Radwa H. Abou-Saleh
JMJames R. McLaughlan
James R. McLaughlan
NINicola Ingram
Nicola Ingram
BJBenjamin R. G. Johnson
Benjamin R. G. Johnson
SEStephen D Evans
Stephen D Evans
Micron sized, lipid stabilized bubbles of gas are of interest as contrast agents for ultra-sound (US) imaging and increasingly as delivery vehicles for targeted, triggered, therapeutic delivery. Microfluidics provides a reproducible means for microbubble production and surface functionalisation. In this study, microbubbles are generated on chip using flow-focussing microfluidic devices that combine streams of gas and liquid through a nozzle a few microns wide and then subjecting the two phases to a downstream pressure drop. While microfluidics has successfully demonstrated the generation of monodisperse bubble populations, these approaches inherently produce low bubble counts. We introduce a new micro-spray flow regime that generates consistently high bubble concentrations that are more clinically relevant compared to traditional monodisperse bubble populations. Final bubble concentrations produced by the micro-spray regime were up to 1010 bubbles mL−1. The technique is shown to be highly reproducible and by using multiplexed chip arrays, the time taken to produce one millilitre of sample containing 1010 bubbles mL−1 was ∼10 min. Further, we also demonstrate that it is possible to attach liposomes, loaded with quantum dots (QDs) or fluorescein, in a single step during MBs formation.

20 February 2019 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
PBPeng Bao
Peng Bao
DPDaniel Alexander Paterson
Daniel Alexander Paterson
PHPatrick L. Harrison
Patrick L. Harrison
KMKeith Miller
Keith Miller
SPSally A. Peyman
Sally A. Peyman
Helen GleesonHelen Gleeson
Helen Gleeson
We describe a novel biosensor based on phospholipid-coated nematic liquid crystal (LC) droplets and demonstrate the detection of Smp43, a model antimicrobial peptide (AMP) from the venom of North African scorpion Scorpio maurus palmatus. Mono-disperse lipid-coated LC droplets of diameter 16.7 ± 0.2 μm were generated using PDMS microfluidic devices with a flow-focusing configuration and were the target for AMPs. The droplets were trapped in a bespoke microfluidic trap structure and were simultaneously treated with Smp43 at gradient concentrations in six different chambers. The disruption of the lipid monolayer by the Smp43 was detected (<6 μM) at concentrations well within its biologically active range, indicated by a dramatic change in the appearance of the droplets associated with the transition from a typical radial configuration to a bipolar configuration, which is readily observed by polarizing microscopy. This suggests the system has feasibility as a drug-discovery screening tool. Further, compared to previously reported LC droplet biosensors, this LC droplet biosensor with a lipid coating is more biologically relevant and its ease of use in detecting membrane-related biological processes and interactions has the potential for development as a reliable, low-cost and disposable point of care diagnostic tool.

15 December 2015 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
SPSally A. Peyman
Sally A. Peyman
JMJames R. McLaughlan
James R. McLaughlan
RARadwa H. Abou-Saleh
Radwa H. Abou-Saleh
GMGemma Marston
Gemma Marston
BJBenjamin R. G. Johnson
Benjamin R. G. Johnson
SEStephen D Evans
Stephen D Evans
Micron-sized lipid-stabilised bubbles of heavy gas have been utilised as contrast agents for diagnostic ultrasound (US) imaging for many years. Typically bubbles between 1 and 8 μm in diameter are produced to enhance imaging in US by scattering sound waves more efficiently than surrounding tissue. A potential area of interest for Contrast Enhanced Ultrasound (CEUS) are bubbles with diameters <1 μm or ‘nanobubbles.’ As bubble diameter decreases, ultrasonic resonant frequency increases, which could lead to an improvement in resolution for high-frequency imaging applications when using nanobubbles. In addition, current US contrast agents are limited by their size to the vasculature in vivo. However, molecular-targeted nanobubbles could penetrate into the extra-vascular space of cancerous tissue providing contrast in regions inaccessible to traditional microbubbles. This paper reports a new microfluidic method for the generation of sub-micron sized lipid stabilised particles containing perfluorocarbon (PFC). The nanoparticles are produced in a unique atomisation-like flow regime at high production rates, in excess of 106 particles per s and at high concentration, typically >1011 particles per mL. The average particle diameter appears to be around 100–200 nm. These particles, suspected of being a mix of liquid and gaseous C4F10 due to Laplace pressure, then phase convert into nanometer sized bubbles on the application of US. In vitro ultrasound characterisation from these nanoparticle populations showed strong backscattering compared to aqueous filled liposomes of a similar size. The nanoparticles were stable upon injection and gave excellent contrast enhancement when used for in vivo imaging, compared to microbubbles with an equivalent shell composition.