Mr. Shifat Hossain

Kookmin University
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2021 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
SGShantanu Sen Gupta
Shantanu Sen Gupta
TKTae-Ho Kwon
Tae-Ho Kwon
Shifat HossainShifat Hossain
Shifat Hossain
Ki-Doo KimKi-Doo Kim
Ki-Doo Kim

13 November 2020 in Electronics
Verified
Journal Article
Open access
PDF file
Partha Pratim BanikPartha Pratim Banik
Partha Pratim Banik
Shifat HossainShifat Hossain
Shifat Hossain
Tae Ho KwonTae Ho Kwon
Tae Ho Kwon
HKHyoungkeun Kim
Hyoungkeun Kim
Ki-Doo KimKi-Doo Kim
Ki-Doo Kim
Clinical devices play a vital role in diagnosing and monitoring people’s health. A pulse oximeter (PO) is one of the most common clinical devices for critical medical care. In this paper, we explain how we developed a wearable PO. We propose a new electronic circuit based on an analog filter that can separate red and green photoplethysmography (PPG) signals, acquire clean PPG signals, and estimate the pulse rate (PR) and peripheral capillary oxygen saturation (SpO2). We propose a PR and SpO2 measurement algorithm with and without the motion artifact. We consider three types of motion artifacts with our acquired clean PPG signal from our proposed electronic circuit. To evaluate our proposed algorithm, we measured the accuracy of our estimated SpO2 and PR. To evaluate the quality of our estimated PR (bpm) and SpO2 (%) with and without the finger motion artifact, we used the quality evaluation metrics: mean absolute percentage error (MAPE), mean absolute error (MAE), and reference closeness factor (RCF). Without the finger motion condition, we found that our proposed wearable PO device achieved an average 2.81% MAPE, 2.08 bpm MAE, 0.97 RCF, and 98.96% SpO2 accuracy. With a finger motion, the proposed wearable PO device achieved an average 4.5% MAPE, 3.66 bpm MAE, 0.96 RCF, and 96.88% SpO2 accuracy. We also show a comparison of our proposed PO device with a commercial Fingertip PO (FPO) device. We have found that our proposed PO device performs better than the commercial FPO device under finger motion conditions. To demonstrate the implementation of our wearable PO, we developed a smartphone app to allow the PO device to share PPG signals, PR, and SpO2 through Bluetooth communication. We also show the possible applications of our proposed PO as a wearable, hand-held PO device, and a PPG signal acquisition system.

17 March 2021 in IEEE Transactions on Consumer Electronics
Verified
Journal Article
Closed access
SGShantanu Sen Gupta
Shantanu Sen Gupta
Shifat HossainShifat Hossain
Shifat Hossain
Ki-Doo KimKi-Doo Kim
Ki-Doo Kim
Image distortion during multiple-exposure capture is a common scenario, and most of the existing legacy image content is in the low dynamic range (LDR). For both of these problems, pseudo multiple exposure image generation from a single image is a possible solution. Hence, in this article, we propose a novel method for high dynamic range (HDR)-like image generation by fusing pseudo-multi-exposure images that are produced from only one single image. The proposed pseudo-exposure image generation method is based on intensity mapping function (IMF). First, our system learns the relation between different exposure images with the help of genetic algorithm and generates long and short exposure images. In the second step, we fuse images with different exposures to generate the HDR-like image. Our method outperforms several inverse tone mapping operator (ITMO)-based methods. The simplicity and good performance of the proposed method makes it suitable for mobile phones and other consumer electronics. We also develop a demo software to validate the proposed method.

19 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Chowdhury Azimul HaqueChowdhury Azimul Haque
Chowdhury Azimul Haque
Shifat HossainShifat Hossain
Shifat Hossain
Tae Ho KwonTae Ho Kwon
Tae Ho Kwon
Ki-Doo KimKi-Doo Kim
Ki-Doo Kim
Continuous monitoring of blood-glucose concentrations is essential for both diabetic and nondiabetic patients to plan a healthy lifestyle. Noninvasive in vivo blood-glucose measurements help reduce the pain of piercing human fingertips to collect blood. To facilitate noninvasive measurements, this work proposes a Monte Carlo photon simulation-based model to estimate blood-glucose concentration via photoplethysmography (PPG) on the fingertip. A heterogeneous finger model was exposed to light at 660 nm and 940 nm in the reflectance mode of PPG via Monte Carlo photon propagation. The bio-optical properties of the finger model were also deduced to design the photon simulation model for the finger layers. The intensities of the detected photons after simulation with the model were used to estimate the blood-glucose concentrations using a supervised machine-learning model, XGBoost. The XGBoost model was trained with synthetic data obtained from the Monte Carlo simulations and tested with both synthetic and real data (n = 35). For testing with synthetic data, the Pearson correlation coefficient (Pearson’s r) of the model was found to be 0.91, and the coefficient of determination (R2) was found to be 0.83. On the other hand, for tests with real data, the Pearson’s r of the model was 0.85, and R2 was 0.68. Error grid analysis and Bland–Altman analysis were also performed to confirm the accuracy. The results presented herein provide the necessary steps for noninvasive in vivo blood-glucose concentration estimation.

26 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Shifat HossainShifat Hossain
Shifat Hossain
Chowdhury Azimul HaqueChowdhury Azimul Haque
Chowdhury Azimul Haque
Ki-Doo KimKi-Doo Kim
Ki-Doo Kim
Diabetes is a serious disease affecting the insulin cycle in the human body. Thus, monitoring blood glucose levels and the diagnosis of diabetes in the early stages is very important. Noninvasive in vivo diabetes-diagnosis procedures are very new and require thorough studies to be error-resistant and user-friendly. In this study, we compare two noninvasive procedures (two-wavelength- and three-wavelength-based methods) to estimate glycated hemoglobin (HbA1c) levels in different scenarios and evaluate them with error level calculations. The three-wavelength method, which has more model parameters, results in a more accurate estimation of HbA1c even when the blood oxygenation (SpO2) values change. The HbA1c-estimation error range of the two-wavelength model, due to change in SpO2, is found to be from −1.306% to 0.047%. On the other hand, the HbA1c estimation error for the three-wavelength model is found to be in the magnitude of 10−14% and independent of SpO2. The approximation of SpO2 from the two-wavelength model produces a lower error for the molar concentration based technique (−4% to −1.9% at 70% to 100% of reference SpO2) as compared to the molar absorption coefficient based technique. Additionally, the two-wavelength model is less susceptible to sensor noise levels (max SD of %error, 0.142%), as compared to the three-wavelength model (max SD of %error, 0.317%). Despite having a higher susceptibility to sensor noise, the three-wavelength model can estimate HbA1c values more accurately; this is because it takes the major components of blood into account and thus becomes a more realistic model.

14 December 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Shifat HossainShifat Hossain
Shifat Hossain
Ki-Doo KimKi-Doo Kim
Ki-Doo Kim
The diagnosis and management of diabetes require frequent monitoring of blood sugar levels. Prolonged exposure of most of the monosaccharides in the bloodstream results in the glycation of hemoglobin. This glycated hemoglobin (HbA1c) based test plays an important role to avoid diabetic complications. However, noninvasive estimation of HbA1c is a very new, promising, and challenging topic in modern bioengineering scopes. The purpose of this study is to develop and verify mathematical models in order to quantify the glycated hemoglobin in-vivo percentage non-invasively. This research utilized photon diffusion theory to develop the finger models and genetic symbolic regression methods to solve the models to estimate the level of glycated hemoglobin in the blood. The validation of these models with human participants indicated a high degree of correlation (0.887 and 0.907 Pearson's r value), and high precision (2.56% and 2.96% coefficient of variation (%CV)) for transmission and reflection type noninvasive digital volume pulse-based signals. This research will be a breakthrough for the application of noninvasive HbA1c estimation.