Chowdhury Azimul Haque

Mr. Chowdhury Azimul Haque

Kookmin University
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Chowdhury Azimul HaqueChowdhury Azimul Haque
Chowdhury Azimul Haque
Tae Ho KwonTae Ho Kwon
Tae Ho Kwon
Ki-Doo KimKi-Doo Kim
Ki-Doo Kim
Blood pressure measurements are one of the most routinely performed medical tests globally. Blood pressure is an important metric since it provides information that can be used to diagnose several vascular diseases. Conventional blood pressure measurement systems use cuff-based devices to measure the blood pressure, which may be uncomfortable and sometimes burdensome to the subjects. Therefore, in this study, we propose a cuffless blood pressure estimation model based on Monte Carlo simulation (MCS). We propose a heterogeneous finger model for the MCS at wavelengths of 905 nm and 940 nm. After recording the photon intensities from the MCS over a certain range of blood pressure values, the actual photoplethysmography (PPG) signals were used to estimate blood pressure. We used both publicly available and self-made datasets to evaluate the performance of the proposed model. In case of the publicly available dataset for transmission-type MCS, the mean absolute errors are 3.32 ± 6.03 mmHg for systolic blood pressure (SBP), 2.02 ± 2.64 mmHg for diastolic blood pressure (DBP), and 1.76 ± 2.8 mmHg for mean arterial pressure (MAP). The self-made dataset is used for both transmission- and reflection-type MCSs; its mean absolute errors are 2.54 ± 4.24 mmHg for SBP, 1.49 ± 2.82 mmHg for DBP, and 1.51 ± 2.41 mmHg for MAP in the transmission-type case as well as 3.35 ± 5.06 mmHg for SBP, 2.07 ± 2.83 mmHg for DBP, and 2.12 ± 2.83 mmHg for MAP in the reflection-type case. The estimated results of the SBP and DBP satisfy the requirements of the Association for the Advancement of Medical Instrumentation (AAMI) standards and are within Grade A according to the British Hypertension Society (BHS) standards. These results show that the proposed model is efficient for estimating blood pressures using fingertip PPG signals.

19 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Chowdhury Azimul HaqueChowdhury Azimul Haque
Chowdhury Azimul Haque
Shifat HossainShifat Hossain
Shifat Hossain
Tae Ho KwonTae Ho Kwon
Tae Ho Kwon
Ki-Doo KimKi-Doo Kim
Ki-Doo Kim
Continuous monitoring of blood-glucose concentrations is essential for both diabetic and nondiabetic patients to plan a healthy lifestyle. Noninvasive in vivo blood-glucose measurements help reduce the pain of piercing human fingertips to collect blood. To facilitate noninvasive measurements, this work proposes a Monte Carlo photon simulation-based model to estimate blood-glucose concentration via photoplethysmography (PPG) on the fingertip. A heterogeneous finger model was exposed to light at 660 nm and 940 nm in the reflectance mode of PPG via Monte Carlo photon propagation. The bio-optical properties of the finger model were also deduced to design the photon simulation model for the finger layers. The intensities of the detected photons after simulation with the model were used to estimate the blood-glucose concentrations using a supervised machine-learning model, XGBoost. The XGBoost model was trained with synthetic data obtained from the Monte Carlo simulations and tested with both synthetic and real data (n = 35). For testing with synthetic data, the Pearson correlation coefficient (Pearson’s r) of the model was found to be 0.91, and the coefficient of determination (R2) was found to be 0.83. On the other hand, for tests with real data, the Pearson’s r of the model was 0.85, and R2 was 0.68. Error grid analysis and Bland–Altman analysis were also performed to confirm the accuracy. The results presented herein provide the necessary steps for noninvasive in vivo blood-glucose concentration estimation.

26 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Shifat HossainShifat Hossain
Shifat Hossain
Chowdhury Azimul HaqueChowdhury Azimul Haque
Chowdhury Azimul Haque
Ki-Doo KimKi-Doo Kim
Ki-Doo Kim
Diabetes is a serious disease affecting the insulin cycle in the human body. Thus, monitoring blood glucose levels and the diagnosis of diabetes in the early stages is very important. Noninvasive in vivo diabetes-diagnosis procedures are very new and require thorough studies to be error-resistant and user-friendly. In this study, we compare two noninvasive procedures (two-wavelength- and three-wavelength-based methods) to estimate glycated hemoglobin (HbA1c) levels in different scenarios and evaluate them with error level calculations. The three-wavelength method, which has more model parameters, results in a more accurate estimation of HbA1c even when the blood oxygenation (SpO2) values change. The HbA1c-estimation error range of the two-wavelength model, due to change in SpO2, is found to be from −1.306% to 0.047%. On the other hand, the HbA1c estimation error for the three-wavelength model is found to be in the magnitude of 10−14% and independent of SpO2. The approximation of SpO2 from the two-wavelength model produces a lower error for the molar concentration based technique (−4% to −1.9% at 70% to 100% of reference SpO2) as compared to the molar absorption coefficient based technique. Additionally, the two-wavelength model is less susceptible to sensor noise levels (max SD of %error, 0.142%), as compared to the three-wavelength model (max SD of %error, 0.317%). Despite having a higher susceptibility to sensor noise, the three-wavelength model can estimate HbA1c values more accurately; this is because it takes the major components of blood into account and thus becomes a more realistic model.

1 April 2026 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PSPegah Safavi
Pegah Safavi
MMMehrana Mohtasebi
Mehrana Mohtasebi
Chowdhury Azimul HaqueChowdhury Azimul Haque
Chowdhury Azimul Haque
FAFaezeh Akbari
Faezeh Akbari
XLXuhui Liu
Xuhui Liu
Guoqiang YuGuoqiang Yu
Guoqiang Yu
SignificanceIntermittent hypoxia (IH) is common in preterm neonates and can cause hypoxic–ischemic brain injury. Simultaneous monitoring of cerebral blood flow (CBF) and oxygenation is essential to detect oxygen delivery-extraction mismatches and guide intervention.AimWe aimed to adapt and test an innovative diffuse speckle contrast flow oximetry (DSCFO) system for continuous monitoring of cerebral hemodynamics during IH in neonatal rats, a model approximating human neonates.ApproachTwo compact laser diodes and a miniature CMOS camera were integrated into a fiber-free probe for continuous monitoring of changes in relative CBF (rCBF) and oxy- and deoxy-hemoglobin concentrations (Δ[HbO2] and Δ[Hb]) in 8-day-old neonatal rats. Sham rats (n=6) underwent 10 min of normoxia, whereas IH rats (n=8) experienced 10 cycles of sequential 2-min hypoxia (8% O2) and 2-min hyperoxia (100% O2).ResultsSham rats maintained stable cerebral hemodynamics under normoxia, whereas IH rats exhibited pronounced periodic fluctuations during IH. Hypoxic episodes caused instantaneous decreases in rCBF and Δ[HbO2] and increases in Δ[Hb], whereas hyperoxic episodes reversed these effects, reducing hypoxic stress. However, the pronounced cerebral hemodynamic fluctuations during IH may still contribute to brain injury.ConclusionsWe demonstrate an affordable, noninvasive, wearable, fiber-free DSCFO system for continuous monitoring of rCBF, Δ[HbO2], and Δ[Hb] during IH in neonatal rats. The system captured hypoxia-induced cerebral deoxygenation and hyperoxia-driven recovery, revealing episode-dependent protective and disruptive mechanisms. Future work will correlate DSCFO findings with neurological and histological outcomes to guide IH interventions in large neonatal animal models and human infants.