This paper considers three-dimensional (3D) computational fluid dynamics (CFD) and structural modeling of brush seals, and investigates the effects of inlet swirl on the bristle pack. The model couples aerodynamic forces generated by CFD to a structural model that includes interaction between bristles. At a critical value of inlet swirl, aerodynamic forces cause circumferential slip of the upstream bristle row. In practice, this may lead to instability of the bristle pack and is consistent with anecdotal reports of seal behavior. The critical swirl velocity was reduced when the downstream pressure level was raised, keeping the same upstream total to downstream static pressure difference. This is caused by the increased dynamic head associated with the inlet swirl. Inclusion of a front plate in the seal design does not offer the intended protection to the bristle pack in highly swirling environments. This is associated with highly swirling flow impinging on the bristle tips. Fitting of roughness elements on the upstream face of the front plate could improve stability by reducing swirl of the flow impacting on the bristles. Increasing the bristle diameter and bristle stiffness does not necessarily prevent slip at higher inlet swirl velocities, but reduces the magnitude of slip of the upstream bristles.
In a cover-plate system, rotating receiver hole is an important component, because its structure and characteristics directly influence the aerodynamic loss and cooling performance in the preswirl system. A new type of vane shaped (VS) receiver hole was designed and presented in this paper. Numerical simulations were carried out to compare the performances among high-radius direct transfer system (model-A), low-radius cover-plate system with simple drilled (SD) receiver holes (model-B), and low-radius cover-plate system with VS receiver holes (model-C). Results indicate that for the operating conditions simulated here, temperature drop effectiveness of the high-radius preswirl system is much better compared to the low-radius system with SD receiver hole. With VS receiver hole, the aerodynamic loss in model-C is the lowest. The nondimensional static pressure at preswirl nozzle exit is only 0.93, around 10% lower than model-B. Moreover, it has a more remarkable cooling performance. The temperature drop effectiveness of model-C can be as high as 0.52, around 67.7% higher compared to model-A. The system with VS receiver hole could not only realize the advantage of low leakage flow as a low-radius system, but also could achieve higher temperature drop compared to high-radius system.
11 February 2019 in Journal of Engineering for Gas Turbines and Power
As performance improvements of compressors become more difficult to obtain, the optimization of stator well structure to control the reverse leakage flow is a more important research subject. Normally, the stator well can be considered as two rotor–stator cavities linked by the labyrinth seal. The flow with high tangential velocity and high total temperature exited from the stator well interacts with the main flow, which can affect the compressor aerodynamic performance. Based on the flow mechanisms in the basic stator well, four geometries were proposed and studied. For geometry a and geometry b, seal lips were attached to the rotor and stator inside downstream rim seal while impellers were positioned in the cavities for geometry c and geometry d. Leakage flow rates, tangential velocities, and pressure distributions in the cavities were analyzed using validated method of computational fluid dynamics. In the current study, where ω = 8000 rpm, π = 1.05–1.30, the maximum reductions of leakage flow rate for geometry a and geometry b are 7.9% and 15.9%, respectively, compared to the baseline model. In addition, the rotating impellers in the downstream cavity for geometry c contribute to a more significant pressure gradient along radial direction, reducing the leakage flow as much as 46%. Although the stationary impellers in the upstream cavity for geometry d appear to have little effect upon the leakage, these impellers can be used to adjust the tangential velocity of ejected flow from the stator well to the mainstream.