Following the urgency of climate change issues, investments in renewable energy sources and electrification of the transportation sector have enormously increased to facilitate the transition to a more sustainable future. However, as renewable resources like wind parks are replacing conventional power plants, new balancing solutions are required to strengthen grid stability. As responsive loads with quick dynamics, electrolyzers operating in hydrogen refueling stations (HRSs) can offer flexible balancing services to the power grid. To gain this benefit, this article examines the techno-economic features of providing different frequency grid services by an HRS, considering the possibility of hydrogen injection into the industrial and natural gas pipelines. The ratings of the subcomponents and dispatch plans are optimized to enhance the performance of the plant. A probabilistic mixed-integer linear programming problem is solved over one year with a time resolution of 1 h and using real-world historical data based on the European electricity market. The simulation results indicate that the economic profits can be increased significantly as a result of participating in the ancillary service markets and meeting its operation specifications while the stable performance of the HRS is guaranteed.
27 November 2017 in IET Generation, Transmission & Distribution
Demand response (DR) is one of the fundamental components of deregulated power systems which face uncertainty because of unpredictable network component contingencies. In this study, a security‐constrained model is proposed to coordinate supply and demand sides in a proper way toward a flexible, secure and economic grid. In the proposed model, generation units are committed to enhance the flexibility by providing up‐ and down‐spinning reserves while an optimal real‐time pricing scheme provides demand‐side flexibility. Real‐time pricing is developed by utilising consumers' behaviour. Different levels of rationality are given by extending demand‐price elasticity matrices for different types of consumers. The proposed method can assist independent system operators to schedule generating units a day‐ahead in a more reliable manner. Customers also can make the most beneficial plans by joining DR programmes and schedule their consumption optimally according to defined rates in the case of an emergency. The applicability of the proposed model is tested on the IEEE 24‐bus reliability test system and its effects on operation cost, technical data of the network and the expected load not served are discussed.