Masoud Aghapour

Dr. Masoud Aghapour

Department for Companion Animals and Horses, University of Veterinary Medicine Vienna, Vienna, Wien, Austria
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2022 in Animals
Verified
Journal Article
Open access
PDF file
Masoud AghapourMasoud Aghapour
Masoud Aghapour
Barbara BockstahlerBarbara Bockstahler
Barbara Bockstahler
Virtual reality and augmented reality are new but rapidly expanding topics in medicine. In virtual reality, users are immersed in a three-dimensional environment, whereas in augmented reality, computer-generated images are superimposed on the real world. Despite advances in human medicine, the number of published articles in veterinary medicine is low. These cutting-edge technologies can be used in combination with existing methods in veterinary medicine to achieve diagnostic/therapeutic and educational goals. The purpose of our review was to evaluate studies for their use of virtual reality and augmented reality in veterinary medicine, as well as human medicine with animal trials, to report results and the state of the art. We collected all of the articles we included in our review by screening the Scopus, PubMed, and Web of Science databases. Of the 24 included studies, 11 and 13 articles belonged to virtual reality and augmented reality, respectively. Based on these articles, we determined that using these technologies has a positive impact on the scientific output of students and residents, can reduce training costs, and can be used in training/educational programs. Furthermore, using these tools can promote ethical standards. We reported the absence of standard operation protocols and equipment costs as study limitations.

28 March 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Masoud AghapourMasoud Aghapour
Masoud Aghapour
Barbara BockstahlerBarbara Bockstahler
Barbara Bockstahler
Sibylle KneisslSibylle Kneissl
Sibylle Kneissl
ATAlexander Tichy
Alexander Tichy
BVBritta Vidoni
Britta Vidoni
Measurement of fore and pelvic limb alignment in veterinary orthopedics is significant, as it is in human medicine. The establishment of reference ranges for alignments and comparing measured ranges in diseased animals to these reference values would allow veterinarians to specify the quantitative degree of an angular deformity, plan suitable treatments and evaluate treatment outcomes. Patellar luxation is a common orthopedic disease in small animal clinics. Severe grades of MPL may present with bone deformities or abnormal alignments; therefore, evaluation of the measurement methods of femoral and tibial alignment in dogs with different grades of patellar luxation to assess the accuracy and reliability of the measurements could be useful. In this retrospective study radiographs of 21 client-owned Chihuahuas that had been presented to the Small Animal Surgery of Vetmeduni Vienna from 2012–2016 with a diagnose of patellar luxation were selected. The measurements were performed on frontal, lateral and axial view radiographs to determine the femoral and tibial angles and to evaluate the intra- and inter-observer variabilities of the protocol. Radiographs of each dog were investigated by three observers. Intra-observer variability was based on measurements by each observer who repeated the protocol two times to evaluate repeatability. Inter-observer variability was based on the measurements between the three observers to evaluate the reproducibility of the protocol. The results of the study showed that 92.85% of inter-observer ICC (intra-class correlation coefficient) had high correlation, and the remaining 7.15% had good correlation. Intra-observer ICCs for measurements of the first observer were 28.57% high correlation and 50% good correlation. For the second observer, 100% high correlation was recorded, and for the third observer 71.42% high correlation and 14.28% good correlation was recorded. These results show that the selected methods have high correlation and could be used as a reliable method in veterinary orthopedics.

17 June 2021 in Animals
Verified
Journal Article
Open access
PDF file
Masoud AghapourMasoud Aghapour
Masoud Aghapour
Barbara BockstahlerBarbara Bockstahler
Barbara Bockstahler
BVBritta Vidoni
Britta Vidoni
The assessment of limb conformations in veterinary orthopedics is a significant tool used to determine the quantitative degree of limb malalignments. As in human medicine, various studies have been undertaken in veterinary medicine to determine the values in different dog breeds and to determine the values in healthy and diseased dogs. The objectives of this systematic review were to evaluate the reported values in these articles separately, to compile the standard values, and to compare the values between dogs with and without various orthopedic diseases. All of the articles included in this systematic review were collected by screening the Scopus, PubMed/Medline, and Web of Science databases. The articles were evaluated according to the measured alignments, imaging methods, dog breeds, and the health status of the dogs. Each alignment was investigated separately, and the results are summarized. Twenty-nine studies were included in this systematic review. According to the studies, in the frontal plane, distal femoral alignments, as well as proximal and distal tibial alignments, corresponded to the severity of the medial patellar luxation. The difference between affected and non-affected dogs with cranial cruciate ligament disease was limited to the proximal tibial alignments in the sagittal plane.

20 February 2025 in Sensors
Verified
Journal Article
Open access
PDF file
CLChristiane Lutonsky
Christiane Lutonsky
Christian PehamChristian Peham
Christian Peham
NANadja Affenzeller
Nadja Affenzeller
Masoud AghapourMasoud Aghapour
Masoud Aghapour
JWJulia Wegscheider
Julia Wegscheider
Barbara BockstahlerBarbara Bockstahler
Barbara Bockstahler
This study investigates the impact of visual input and aging on postural stability (PS) in dogs by analyzing center-of-pressure (COP) parameters during static posturography under sighted (EO) and blindfolded (EC) conditions. Twenty adult (75% of fractional lifespan) dogs, free from orthopedic, neurological, or visual impairments, were assessed using a pressure measurement plate. While no significant differences were found between adult and senior dogs under standard EO conditions, blindfolding revealed age-related disparities. Senior dogs exhibited significantly higher craniocaudal displacement and support surface values compared to adult dogs, indicating a greater reliance on visual input for sagittal stability. Conversely, adult dogs exhibited a reduction in postural sway during EC conditions, indicating an adaptive shift toward greater reliance on somatosensory input. These findings highlight diminished sensory integration and adaptability in senior dogs, correlating with aging-related declines in proprioception and sensory processing. This research underscores the critical role of vision in canine PS, particularly in older individuals, and emphasizes the need for targeted interventions, such as balance training, to enhance sensory integration and mitigate fall risk in aging dogs. Future studies should explore dynamic and multimodal challenges to further elucidate compensatory mechanisms.

6 February 2021 in Animals
Verified
Journal Article
Open access
PDF file
BVBritta Vidoni
Britta Vidoni
VBVeronika Bauer
Veronika Bauer
Barbara BockstahlerBarbara Bockstahler
Barbara Bockstahler
MGMichaela Gumpenberger
Michaela Gumpenberger
ATAlexander Tichy
Alexander Tichy
Masoud AghapourMasoud Aghapour
Masoud Aghapour
Canine hip dysplasia is a multifactorial disorder characterized by hip laxity and osteoarthritis. The early diagnosis of hip laxity is an important topic in small animal orthopedics. This study aimed to evaluate the correlation between clinical orthopedic examinations and the Fédération Cynologique Internationale (FCI) scoring method. Thirty purebred Rottweilers were examined at approximately four (20 ± 2 weeks), eight (35 ± 2 weeks), and twelve months of age (54 ± 1 weeks), respectively. The Ortolani, Barlow, and Bardens tests and reduction/subluxation angle measurements were performed at each time. FCI scoring was conducted at the third examination time. Positive correlations were recorded between the reduction angle and Ortolani test, reduction angle and FCI score, and Ortolani test and FCI score for the second and third examination dates. No correlation was observed between the subluxation angle and other methods. Despite previous studies reporting 16–20 weeks as the earliest age for diagnosing hip laxity in dogs, in our study, early diagnosis was possible from the age of 35 ± 2 weeks. This difference might originate from the small sample size, low number of the dogs with severe grades of laxity, and breed differences.

14 March 2024 in Frontiers in Veterinary Science
Verified
Journal Article
Open access
Masoud AghapourMasoud Aghapour
Masoud Aghapour
NANadja Affenzeller
Nadja Affenzeller
CLChristiane Lutonsky
Christiane Lutonsky
CPChristian Peham
Christian Peham
ATAlexander Tichy
Alexander Tichy
BBBarbara Bockstahler
Barbara Bockstahler
Introduction: Center of pressure (COP) parameters are frequently assessed to analyze movement disorders in humans and animals. Methodological discrepancies are a major concern when evaluating conflicting study results. This study aimed to assess the inter-observer reliability and test-retest reliability of body COP parameters including mediolateral and craniocaudal sway, total length, average speed and support surface in healthy dogs during quiet standing on a pressure plate. Additionally, it sought to determine the minimum number of trials and the shortest duration necessary for accurate COP assessment.Materials and methods: Twelve clinically healthy dogs underwent three repeated trials, which were analyzed by three independent observers to evaluate inter-observer reliability. Test-retest reliability was assessed across the three trials per dog, each lasting 20 seconds (s). Selected 20 s measurements were analyzed in six different ways: 1 × 20 s, 1 × 15 s, 2 × 10 s, 4 × 5 s, 10 × 2 s, and 20 × 1 s.Results: Results demonstrated excellent inter-observer reliability (ICC ≥ 0.93) for all COP parameters. However, only 5 s, 10 s, and 15 s measurements achieved the reliability threshold (ICC ≥ 0.60) for all evaluated parameters.Discussion: The shortest repeatable durations were obtained from either two 5 s measurements or a single 10 s measurement. Most importantly, statistically significant differences were observed between the different measurement durations, which underlines the need to standardize measurement times in COP analysis. The results of this study aid scientists in implementing standardized methods, thereby easing comparisons across studies and enhancing the reliability and validity of research findings in veterinary medicine.