Concrete and wood are commonly used to manufacture artificial reefs (ARs) worldwide for marine resource enhancement and habitat restoration. Although microbial biofilms play an important role in marine ecosystems, the microbial communities that colonize concrete and wooden ARs and their temporal succession have rarely been studied. In this study, the temporal succession of the microbial communities on concrete and wooden AR blocks and the driving factors were investigated. The composition of the microbial communities underwent successive shifts over time: among the six dominant phyla, the relative abundances of Proteobacteria, Cyanobacteria and Gracilibacteria significantly decreased in wood, as did that of Cyanobacteria in concrete. Operational taxonomic units (OTU) richness and Shannon index were significantly higher in concrete than in wood. Non-metric multidimensional scaling ordination placed the microbial communities in two distinct clusters corresponding to the two substrate materials. The macrobenthic compositions of concrete and wood were broadly similar and shifted over time, especially in the first five weeks. The Shannon index of the microbial communities in concrete and wood increased significantly with the organism coverage. The results provide fundamental data on microbial community succession during the initial deployment of ARs and contribute to understanding the ecological effects of ARs.
The anaerobic membrane bioreactors (AnMBR) with ring membrane module were operated under mesophilic temperature (M-AnMBR) and atmospheric temperature (A-AnMBR). Compared to the M-AnMBR, the removal efficiency of the A-AnMBR was found to be lower and the faster membrane fouling occurred in the A-AnMBR under corresponding hydraulic retention time (HRT). The MiSeq high-throughput sequencing was applied to analyze the microbial community structure. The HRT change had different effects on the community richness and diversity of the cake and bulk sludge. The abundance of phylum Proteobacteria in the M-AnMBR was higher than that in the A-AnMBR, which should account for the higher removal of nutrients in the M-AnMBR. The faster membrane fouling would occur in the A-AnMBR due to the relatively high abundance of Bacteroidetes in the bulk sludge and cake sludge. Moreover, specific comparison down to the genus level showed that the dominant abundant bacterial genera were Candidate division OP8 norank and Anaerolineaceae uncultured in the cake sludge for M-AnMBR, and were VadinHA17 norank, WCHB1-69 norank, VadinBC27 wastewater-sludge group, and Synergistaceae uncultured in the cake sludge for A-AnMBR The different representative genera with the variation of the HRTs for the two bioreactors might indicate the different performance between the two AnMBRs.
A microalgae membrane bioreactor (MMBR) with internal circulating fluidized bed (ICFB) was constructed at room temperature to study the removal efficiency of marine aquaculture wastewater pollutants and continuously monitor the biomass of microalgae. Within 40 days of operation, the removal efficiency of NO3−–N and NH4+–N in the ICFB-MMBR reached 52% and 85%, respectively, and the removal amount of total nitrogen (TN) reached 16.2 mg/(L·d). In addition, the reactor demonstrated a strong phosphorus removal capacity. The removal efficiency of PO43−–P reached 80%. With the strengthening of internal circulation, the microalgae could be distributed evenly and enriched quickly. The maximum growth rate and biomass concentration reached 60 mg/(L·d) and 1.4 g/L, respectively. The harvesting of microalgae did not significantly affect the nitrogen and phosphorus removal efficiency of ICFB-MMBR. The membrane fouling of the reactor was investigated by monitoring transmembrane pressure difference (TMP). Overall, the membrane fouling cycle of ICFB-MMBR system was more than 40 days.
In this study, the characteristics of activated sludge flocs were investigated and their effects on the evolution of membrane fouling were considered in the anaerobic membrane bioreactors (AnMBR), which were operated at 25 and 35 °C for municipal wastewater treatment. It was found that the membrane fouling rate of the AnMBR at 25 °C was more severe than that at 35 °C. The membrane fouling trends were not consistent with the change in the concentration of soluble microbial product (SMP). The larger amount of SMP in the AnMBR at 35 °C did not induce more severe membrane fouling than that in the AnMBR at 25 °C. However, the polysaccharide and protein concentration of extracellular polymeric substance (EPS) was higher in the AnMBR at 25 °C in comparison with that in the AnMBR at 35 °C, and the protein/polysaccharide ratio of the EPS in the AnMBR at 25 °C was higher in contrast to that in the AnMBR at 35 °C. Meanwhile, the fouling tendencies measured for the AnMBRs could be related to the characteristics of loosely bound EPS and tightly bound EPS. The analysis of the activated sludge flocs characteristics indicated that a smaller sludge particle size and more fine flocs were observed at the AnMBR with 25 °C. Therefore, the membrane fouling potential in the AnMBR could be explained by the characteristics of activated sludge flocs.
Based on carboxylated multi-walled carbon nanotubes (MWCNTs-COOH), a MWCNTs/PVDF conductive membrane was prepared by a vacuum filtration cross-linking method. The surface compositions and morphology of conductive membranes were studied by X-ray photoelectron spectroscopy and high-resolution field emission scanning electron microscopy, respectively. The effects of cross-linked polymeric polyvinyl alcohol (PVA) on the conductive membrane properties such as the porosity, pore size distribution, pure water flux, conductivity, hydrophilicity, stability and antifouling properties were investigated. Results showed that the addition of PVA to the MWCNTs/PVDF conductive membrane decreased the pure water flux, porosity and the conductivity. However, the hydrophilicity of the modified MWCNTs/PVDF conductive membrane was greatly improved, and the contact angle of pure water was reduced from 70.18° to 25.48° with the addition of PVA contents from 0 wt% to 0.05 wt%. Meanwhile, the conductive membranes with higher content had a relatively higher stability. It was found that the conductive functional layer of the conductive membrane had an average mass loss rate of 1.22% in the 30 min ultrasonic oscillation experiment. The tensile intensity and break elongation ratio of the conductive membrane are improved by the addition of PVA, and the durability of the conductive membrane with PVA was superior to that without PVA added. The electric assisted anti-fouling experiments of modified conductive membrane indicated that compared with the condition without electric field, the average flux attenuation of the conductive membrane was reduced by 11.2%, and the membrane flux recovery rate reached 97.05%. Moreover, the addition of PVA could accelerate the clean of the conductive membranes.