Jianqing Wang

Prof. Jianqing Wang

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2006 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
BBB.B. Beard
B.B. Beard
WKW. Kainz
W. Kainz
TOT. Onishi
T. Onishi
TIT. Iyama
T. Iyama
SWS. Watanabe
S. Watanabe
NNN. Nikoloski
N. Nikoloski
The specific absorption rates (SAR) determined computationally in the specific anthropomorphic mannequin (SAM) and anatomically correct models of the human head when exposed to a mobile phone model are compared as part of a study organized by IEEE Standards Coordinating Committee 34, Sub-Committee 2, and Working Group 2, and carried out by an international task force comprising 14 government, academic, and industrial research institutions. The detailed study protocol defined the computational head and mobile phone models. The participants used different finite-difference time-domain software and independently positioned the mobile phone and head models in accordance with the protocol. The results show that when the pinna SAR is calculated separately from the head SAR, SAM produced a higher SAR in the head than the anatomically correct head models. Also the larger (adult) head produced a statistically significant higher peak SAR for both the 1- and 10-g averages than did the smaller (child) head for all conditions of frequency and position.

8 August 2006 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
JWJianqing Wang
Jianqing Wang
OFOsamu Fujiwara
Osamu Fujiwara
SKSachiko Kodera
Sachiko Kodera
SWSoichi Watanabe
Soichi Watanabe
Due to the difficulty of the specific absorption rate (SAR) measurement in an actual human body for electromagnetic radio-frequency (RF) exposure, in various compliance assessment procedures the incident electric field or power density is being used as a reference level, which should never yield a larger whole-body average SAR than the basic safety limit. The relationship between the reference level and the whole-body average SAR, however, was established mainly based on numerical calculations for highly simplified human modelling dozens of years ago. Its validity is being questioned by the latest calculation results. In verifying the validity of the reference level with respect to the basic SAR limit for RF exposure, it is essential to have a high accuracy of human modelling and numerical code. In this study, we made a detailed error analysis in the whole-body average SAR calculation for the finite-difference time-domain (FDTD) method in conjunction with the perfectly matched layer (PML) absorbing boundaries. We derived a basic rule for the PML employment based on a dielectric sphere and the Mie theory solution. We then attempted to clarify to what extent the whole-body average SAR may reach using an anatomically based Japanese adult model and a scaled child model. The results show that the whole-body average SAR under the ICNIRP reference level exceeds the basic safety limit nearly 30% for the child model both in the resonance frequency and 2 GHz band.

14 June 2017 in Healthcare Technology Letters
Verified
Journal Article
Open access
PDF file
SNShuto Nagai
Shuto Nagai
DADaisuke Anzai
Daisuke Anzai
JWJianqing Wang
Jianqing Wang
Wearable Electrocardiogram (ECG) is attracting much attention in daily healthcare applications. From the viewpoint of long‐term use, it is desired that the electrodes are non‐contact with the human body. In this study, the authors propose an algorithm using the stationary wavelet transform (SWT) to remove motion artefact superimposed on ECG signal when using non‐contact capacitively coupling electrodes. The authors evaluate the effect on motion artefact removal of this algorithm by applying it to various ECG signals with motion artefacts superimposed. As a result, the correlation coefficients of ECG signals with respect to the clean ones have been improved from 0.71 to 0.88 on median before and after motion artefact removal, which demonstrates the validity of the proposed SWT‐based algorithm.

1 January 2017 in Journal of Radiation Research
Verified
Journal Article
Open access
PDF file
TSTomoyuki Shirai
Tomoyuki Shirai
JWJianqing Wang
Jianqing Wang
MKMayumi Kawabe
Mayumi Kawabe
KWKanako Wake
Kanako Wake
SWSo-Ichi Watanabe
So-Ichi Watanabe
OFOsamu Fujiwara
Osamu Fujiwara
In everyday life, people are exposed to radiofrequency (RF) electromagnetic fields (EMFs) with multiple frequencies. To evaluate the possible adverse effects of multifrequency RF EMFs, we performed an experiment in which pregnant rats and their delivered offspring were simultaneously exposed to eight different communication signal EMFs (two of 800 MHz band, two of 2 GHz band, one of 2.4 GHz band, two of 2.5 GHz band and one of 5.2 GHz band). Thirty six pregnant Sprague-Dawley (SD) 10-week-old rats were divided into three groups of 12 rats: one control (sham exposure) group and two experimental (low- and high-level RF EMF exposure) groups. The whole body of the mother rats was exposed to the RF EMFs for 20 h per day from Gestational Day 7 to weaning, and F1 offspring rats (46–48 F1 pups per group) were then exposed up to 6 weeks of age also for 20 h per day. The parameters evaluated included the growth, gestational condition and organ weights of the dams; the survival rates, development, growth, physical and functional development, memory function, and reproductive ability of the F1 offspring; and the embryotoxicity and teratogenicity in the F2 rats. No abnormal findings were observed in the dams or F1 offspring exposed to the RF EMFs or to the F2 offspring for any of the parameters evaluated. Thus, under the conditions of the present experiment, simultaneous whole-body exposure to eight different communication signal EMFs at frequencies between 800 MHz and 5.2 GHz did not show any adverse effects on pregnancy or on the development of rats.

30 July 2013 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
JCJerdvisanop Chakarothai
Jerdvisanop Chakarothai
JWJianqing Wang
Jianqing Wang
OFOsamu Fujiwara
Osamu Fujiwara
KWKanako Wake
Kanako Wake
SWSoichi Watanabe
Soichi Watanabe
In order to determine the whole-body exposure level in small animals inside a reverberation chamber (RC), an ideal electromagnetic (EM) environment has often been assumed inside an RC for numerical dosimetry analyses. In an RC where a strong EM coupling between antennas and animals exists, however, such an EM environment is difficult to be realized, so that it remains unknown whether or not the RC could provide a target dosimetry. In this study, we adopt the Poggio-Miller-Chang-Harrington-Wu-Tsai formulation of the method of moments to directly determine the specific absorption rate (SAR) of a rectangular dielectric phantom placed in an RC, and we demonstrated its validity via comparing the numerical temperature rise with those obtained from experiments. We then demonstrated a nonideal EM environment inside an RC using a prolate spheroid as an exposure target. Furthermore, we performed dosimetry evaluation for multiple rat-shaped tissue-equivalent phantoms inside the RC and determined their whole-body average SARs for many orientations and arrangements of the phantoms. Finally, based on our numerical results, we offered a design rule when using an RC as a whole-body exposure system for small animals.

1 July 2009 in Radiation Research
Verified
Journal Article
Closed access
HMHiroshi Masuda
Hiroshi Masuda
AUAkira Ushiyama
Akira Ushiyama
MTMiyuki Takahashi
Miyuki Takahashi
JWJianqing Wang
Jianqing Wang
OFOsamu Fujiwara
Osamu Fujiwara
COChiyoji Ohkubo
Chiyoji Ohkubo
Masuda, H., Ushiyama, A., Takahashi, M., Wang, J., Fujiwara, O., Hikage, T., Nojima, T., Fujita, K., Kudo, M. and Ohkubo, C. Effects of 915 MHz Electromagnetic-Field Radiation in TEM Cell on the Blood-Brain Barrier and Neurons in the Rat Brain. Radiat. Res. 172, 66-73 (2009). The aim of this study was to determine whether albumin leakage and dark neurons were present in rat brains 14 and 50 days after a single 2-h exposure to a 915 MHz electromagnetic field, as reported by Salford et al. (Environ. Health Perspect. 111, 881–883, 203). Sixty-four male F344 rats (12 weeks old) were exposed to a 915 MHz electromagnetic field at whole-body average specific absorption rates of 0, 0.02, 0.2 and 2.0 W/kg in TEM cells for 2 h, following the protocol reported by Salford et al. The brains were examined histologically and immunohistochemically. No albumin immunoreactivity was observed in the exposed groups. In addition, dark neurons, assessed using hematoxylin and eosin staining, were rarely present, with no statistically significant difference between exposed and sham-exposed animals. This study thus failed to confirm the results of Salford et al.