Novel data for the conductivities of the tissues composing the skin, which are the epidermis, dermis and subcutaneous tissue, were obtained at intermediate frequencies by in vitro measurement. The conductivity of the epidermis was determined from those of the dermis and bulk skin. The conductivities of the dermis and subcutaneous tissue were almost constant from 10 kHz to 1 MHz. On the other hand, a frequency dependence was observed for the epidermis; the conductivity decreases with decreasing frequency. It was found that the conductivity of bulk skin is not determined by that of the dermis but by that of the epidermis. The presented data are expected to contribute to the assessment of safety and to the research and development of medical applications.
30 July 2013 in IEEE Transactions on Microwave Theory and Techniques
In order to determine the whole-body exposure level in small animals inside a reverberation chamber (RC), an ideal electromagnetic (EM) environment has often been assumed inside an RC for numerical dosimetry analyses. In an RC where a strong EM coupling between antennas and animals exists, however, such an EM environment is difficult to be realized, so that it remains unknown whether or not the RC could provide a target dosimetry. In this study, we adopt the Poggio-Miller-Chang-Harrington-Wu-Tsai formulation of the method of moments to directly determine the specific absorption rate (SAR) of a rectangular dielectric phantom placed in an RC, and we demonstrated its validity via comparing the numerical temperature rise with those obtained from experiments. We then demonstrated a nonideal EM environment inside an RC using a prolate spheroid as an exposure target. Furthermore, we performed dosimetry evaluation for multiple rat-shaped tissue-equivalent phantoms inside the RC and determined their whole-body average SARs for many orientations and arrangements of the phantoms. Finally, based on our numerical results, we offered a design rule when using an RC as a whole-body exposure system for small animals.
This paper presents a quantitative analysis of the differences between the various definitions of spatially averaged power densities ( $sIPD_{s}$ ) for localized exposure to electromagnetic near-fields at frequencies from 6 to 100 GHz. The spatially averaged modulus of the complex Poynting vector ( $sIPD_{mod}$ ) and spatially averaged norm of the real part of the complex Poynting vector ( $sIPD_{norm}$ ) were compared using numerical approaches, where their relationships with the spatially averaged absorbed power density ( sAPD ) and the local peak temperature elevation on skin tissue were analyzed. Our results demonstrated that outside the typical boundary of the reactive near-field, i.e., $> \lambda $ /( $2\pi$ ), which is used as a rough guide of the applicable condition for reference levels in the RF safety guidelines, but at most 10 mm from the radiation source, the maximum difference between $sIPD_{norm}$ and $sIPD_{mod}$ is smaller than 0.7 dB from 6 to 100 GHz. For the appropriate conditions recommended in the RF safety guidelines, the differences between the ratios of sAPD to $sIPD_{s}$ and those for the plane-wave normal incidence, are at most 1.4 dB and 0.9 dB for $sIPD_{norm}$ and $sIPD_{mod}$ , respectively. Under the same condition, the ratios of the temperature rise to $sIPD_{s}$ for the relatively small antennas (total dimension less than $2\lambda$ ) do not significantly exceed that for the plane-wave normal incidence, which means that the expected maximum temperature rise is lower than the temperature rise that is derived from the operational health effect threshold in terms of the temperature rise divided with the reduction factors employed in the RF safety guidelines. The above results provide suggestive evidence that the effect of the definition of $sIPD_{s}$ on the human exposure characteristics is not significant compared with those of the other factors, i.e., the antenna type (size), frequency, distance from the source, and averaging area.
A worldwide epidemiological study called 'INTERPHONE' has been conducted to estimate the hypothetical relationship between brain tumors and mobile phone use. In this study, we proposed a method to estimate 3D distribution of the specific absorption rate (SAR) in the human head due to mobile phone use to provide the exposure gradient for epidemiological studies. 3D SAR distributions due to exposure to an electromagnetic field from mobile phones are estimated from mobile phone compliance testing data for actual devices. The data for compliance testing are measured only on the surface in the region near the device and in a small 3D region around the maximum on the surface in a homogeneous phantom with a specific shape. The method includes an interpolation/extrapolation and a head shape conversion. With the interpolation/extrapolation, SAR distributions in the whole head are estimated from the limited measured data. 3D SAR distributions in the numerical head models, where the tumor location is identified in the epidemiological studies, are obtained from measured SAR data with the head shape conversion by projection. Validation of the proposed method was performed experimentally and numerically. It was confirmed that the proposed method provided good estimation of 3D SAR distribution in the head, especially in the brain, which is the tissue of major interest in epidemiological studies. We conclude that it is possible to estimate 3D SAR distributions in a realistic head model from the data obtained by compliance testing measurements to provide a measure for the exposure gradient in specific locations of the brain for the purpose of exposure assessment in epidemiological studies. The proposed method has been used in several studies in the INTERPHONE.
20 August 2021 in IEEE Transactions on Electromagnetic Compatibility
In modern communication systems including the fifth-generation mobile communication system (5G), quasi-millimeter, and millimeter wave frequencies above 6 GHz are utilized. At these frequencies, the incident power density is employed as a metric to assess the compliance of wireless devices to human exposure limits in international guidelines and national regulations. In this article, the performance of the inverse source method (ISM) for incident power density evaluation is investigated in terms of accuracy and operational costs, i.e., measurement and computational costs. The ISM is based on the surface equivalence theorem, and it reconstructs the incident power density close to the device under test from a field measured in a more distant region. The comparison of the performance between the ISM and the conventional plane-wave spectrum method by computational simulation shows that the ISM has an advantage over the conventional method in robustness to the truncation of the measurement region. The ISM reduces the number of measurement points to a quarter for the reconstruction of the spatially averaged incident power density in an error less than 0.4 dB. These findings in the computational simulations are also validated by the measurements of a standard horn antenna and array antennas operated at 28 GHz.
1 August 2018 in IEEE Transactions on Antennas and Propagation
A novel frequency-dependent finite-difference time-domain (FDTD) method, previously proposed by the author, is applied to numerical dosimetry of exposures by an electromagnetic (EM) pulse incident to biological bodies, which are characterized by four Cole–Cole relaxation terms. The proposed method applies the fast inverse Laplace transform to determine the time-domain impulse responses of the complex permittivity function and utilizes Prony’s method to determine the infinite impulse response representation in the $z$ -domain. The FDTD formulation for the update of the electric field is then directly derived by using the $z$ -transformation. The validity of the method is demonstrated by the 3-D analyses of a homogeneous dielectric sphere and a multilayer sphere illuminated by an EM pulse. It is demonstrated that the numerical results of induced electric field distributions inside the spheres are in good agreement with those derived from Mie’s theory over a broad frequency range, proving the validity of the proposed method. Finally, numerical dosimetry of a heterogeneous human head excited by an EM pulse is performed and specific energy absorption due to the pulse illumination is calculated by using the proposed method.