Claudia de los Angeles Miranda

Dr. Claudia de los Angeles Miranda


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
CMClaudia de los Angeles Miranda
Claudia de los Angeles Miranda
Luis Javier Chirosa RíosLuis Javier Chirosa Ríos
Luis Javier Chirosa Ríos
IGIsabel María Guisado-Requena
Isabel María Guisado-Requena
Pedro Delgado-FloodyPedro Delgado-Floody
Pedro Delgado-Floody
Daniel Jerez-MayorgaDaniel Jerez-Mayorga
Daniel Jerez-Mayorga
Background: This study aimed to report, through a systematic review of the literature, the baseline and final reference values obtained by near-infrared spectroscopy (NIRS) of muscle oxygen saturation (SmO2) during resistance training in healthy adults. Methods: Original research studies were searched from four databases (Scopus, PubMed, WOS, and SportDiscus). Subsequently, three independent reviewers screened the titles and abstracts, followed by full-text reviews to assess the studies’ eligibility. Results: Four studies met the inclusion criteria, data were extracted and methodological quality was assessed using the Downs and Black scale. Muscle oxygen saturation (% SmO2) during reported muscle strength exercises showed a decreasing trend after a muscle strength protocol; that is, before the protocol (range = 68.07–77.9%) and after (range = 9.50–46.09%). Conclusions: The trend of the SmO2 variables is to decrease after a muscle strength protocol. Studies are lacking that allow expanding the use of these devices during this type of training.

Daniel Jerez-MayorgaDaniel Jerez-Mayorga
Daniel Jerez-Mayorga
Álvaro Huerta OjedaÁlvaro Huerta Ojeda
Álvaro Huerta Ojeda
Luis Javier Chirosa RíosLuis Javier Chirosa Ríos
Luis Javier Chirosa Ríos
FGFrancisco Guede-Rojas
Francisco Guede-Rojas
IGIris Guzmán-Guzmán
Iris Guzmán-Guzmán
Pedro Delgado-FloodyPedro Delgado-Floody
Pedro Delgado-Floody
Background: The purpose of this study was to determine the reliability for the strength and movement velocity of the concentric phase from the five Sit-to-Stand (5STS), using three incremental loads measured by a functional electromechanical dynamometer (FEMD) in healthy young adults. Methods: The average and peak strength and velocity values of sixteen healthy adults (mean ± standard deviation (SD): age = 22.81 ± 2.13 years) were recorded at 5, 10 and 15 kg. To evaluate the reliability of FEMD, the intraclass correlation coefficient (ICC), standard error of measurement (SEM) and coefficient of variation (CV) were obtained. Results: Reliability was high for the 10 kg (CV range: 3.70–4.18%, ICC range: 0.95–0.98) and 15 kg conditions (CV range: 1.64–3.02%, ICC: 0.99) at average and peak strength, and reliability was high for the 5 kg (CV range: 1.71–2.84%, ICC range: 0.96–0.99), 10 kg (CV range: 0.74–1.84%, ICC range: 0.99–1.00) and 15 kg conditions (CV range: 0.79–3.11%, ICC range: 0.99–1.00) at average and peak velocity. Conclusions: The findings of this study demonstrate that FEMD is a reliable instrument to measure the average and peak strength and velocity values during the five STS in healthy young adults.

10 June 2024 in Obesity Reviews
Verified
Journal Article
Closed access
PIPaulina Ibacache-Saavedra
Paulina Ibacache-Saavedra
EMElena Martínez-Rosales
Elena Martínez-Rosales
Daniel Jerez-MayorgaDaniel Jerez-Mayorga
Daniel Jerez-Mayorga
CMClaudia de los Angeles Miranda
Claudia de los Angeles Miranda
Enrique G. ArteroEnrique G. Artero
Enrique G. Artero
MCMarcelo Cano‐Cappellacci
Marcelo Cano‐Cappellacci

CMClaudia de los Angeles Miranda
Claudia de los Angeles Miranda
IGIsabel María Guisado-Requena
Isabel María Guisado-Requena
Pedro Delgado-FloodyPedro Delgado-Floody
Pedro Delgado-Floody
LALEONIDAS ARIAS
LEONIDAS ARIAS
Alejandro Pérez-CastillaAlejandro Pérez-Castilla
Alejandro Pérez-Castilla
Luis Javier Chirosa RíosLuis Javier Chirosa Ríos
Luis Javier Chirosa Ríos
Background: The objective of this study was to establish the reliability of the Humon Hex near-infrared reflectance spectroscopy (NIRS) in determining muscle oxygen saturation (SmO2) and hemoglobin concentration (Hgb) at rest and during isometric and dynamic strength exercises using a functional electromechanical dynamometer (FEMD). Methods: The SmO2 and Hgb values of sixteen healthy adults (mean ± standard deviation (SD): Age = 36.1 ± 6.4 years) were recorded at rest and during isometry (8 s), dynamic strength I (initial load of 40% of the average isometric load, with 2 kg increments until muscle failure) and dynamic strength II (same as I, but with an initial load of 40% of the maximum isometric load) activity. To evaluate the reliability in the determination of SmO2 and Hgb of this device, intraclass correlation coefficient (ICC), standard error of measurement (SEM) and coefficient of variation (CV) were obtained. Results: The main results obtained are SmO2 at rest (CV = 5.76%, SEM = 3.81, ICC = 0.90), isometric strength (CV = 3.03%, SEM = 2.08, ICC = 0.92), dynamic strength I (CV = 10.6, SEM = 7.17, ICC = 0.22) and dynamic strength II (CV = 9.69, SEM = 6.75, ICC = 0.32); Hgb at rest (CV = 1.97%, SEM = 0.24, ICC = 0.65), isometric strength (CV = 0.98%, SEM = 0.12, ICC = 0.96), dynamic strength I (CV = 3.25, SEM = 0.40, ICC = 0.54) and dynamic strength II (CV = 2.74, SEM = 0.34, ICC = 0.65). Conclusions: The study shows that Humon Hex is a reliable device to obtain SmO2 and Hgb data in healthy adult subjects at rest and during isometric strength, providing precision for measurements made with this device.

2 June 2020 in Obesity Surgery
Verified
Journal Article
Closed access
PDF file
PIPaulina Ibacache-Saavedra
Paulina Ibacache-Saavedra
PCPaulina Cárcamo
Paulina Cárcamo
CMClaudia de los Angeles Miranda
Claudia de los Angeles Miranda
ABAndrés Bottinelli
Andrés Bottinelli
JGJaime Guzmán
Jaime Guzmán
MCMarcelo Cano-Cappellacci
Marcelo Cano-Cappellacci

19 December 2021 in Obesity Reviews
Verified
Journal Article
Closed access
PDF file
PIPaulina Ibacache-Saavedra
Paulina Ibacache-Saavedra
Daniel Jerez-MayorgaDaniel Jerez-Mayorga
Daniel Jerez-Mayorga
ACAlejandro Carretero‐Ruiz
Alejandro Carretero‐Ruiz
CMClaudia de los Angeles Miranda
Claudia de los Angeles Miranda
MCMarcelo Cano‐Cappellacci
Marcelo Cano‐Cappellacci
Enrique G. ArteroEnrique G. Artero
Enrique G. Artero