Background: There has been a recent increased interest in monitoring health using wearable sensor technologies; however, few have focused on breathing. The ability to monitor breathing metrics may have indications both for general health as well as respiratory conditions such as asthma, where long-term monitoring of lung function has shown promising utility. Objective: In this paper, we explore a long short-term memory (LSTM) architecture and predict measures of interbreath intervals, respiratory rate, and the inspiration-expiration ratio from a photoplethysmogram signal. This serves as a proof-of-concept study of the applicability of a machine learning architecture to the derivation of respiratory metrics. Methods: A pulse oximeter was mounted to the left index finger of 9 healthy subjects who breathed at controlled respiratory rates. A respiratory band was used to collect a reference signal as a comparison. Results: Over a 40-second window, the LSTM model predicted a respiratory waveform through which breathing metrics could be derived with a bias value and 95% CI. Metrics included inspiration time (–0.16 seconds, –1.64 to 1.31 seconds), expiration time (0.09 seconds, –1.35 to 1.53 seconds), respiratory rate (0.12 breaths per minute, –2.13 to 2.37 breaths per minute), interbreath intervals (–0.07 seconds, –1.75 to 1.61 seconds), and the inspiration-expiration ratio (0.09, –0.66 to 0.84). Conclusions: A trained LSTM model shows acceptable accuracy for deriving breathing metrics and could be useful for long-term breathing monitoring in health. Its utility in respiratory disease (eg, asthma) warrants further investigation.
The ability to continuously monitor breathing metrics may have indications for general health as well as respiratory conditions such as asthma. However, few studies have focused on breathing due to a lack of available wearable technologies. To examine the performance of two machine learning algorithms in extracting breathing metrics from a finger-based pulse oximeter, which is amenable to long-term monitoring. Methods: Pulse oximetry data were collected from 11 healthy and 11 with asthma subjects who breathed at a range of controlled respiratory rates. U-shaped network (U-Net) and Long Short-Term Memory (LSTM) algorithms were applied to the data, and results compared against breathing metrics derived from respiratory inductance plethysmography measured simultaneously as a reference. Results: The LSTM vs. U-Net model provided breathing metrics which were strongly correlated with those from the reference signal (all p < 0.001, except for inspiratory: expiratory ratio). The following absolute mean bias (95% confidence interval) values were observed (in seconds): inspiration time 0.01(−2.31, 2.34) vs. −0.02(−2.19, 2.16), expiration time −0.19(−2.35, 1.98) vs. −0.24(−2.36, 1.89), and inter-breath intervals −0.19(−2.73, 2.35) vs. −0.25(2.76, 2.26). The inspiratory:expiratory ratios were −0.14(−1.43, 1.16) vs. −0.14(−1.42, 1.13). Respiratory rate (breaths per minute) values were 0.22(−2.51, 2.96) vs. 0.29(−2.54, 3.11). While percentage bias was low, the 95% limits of agreement was high (~35% for respiratory rate). Conclusion: Both machine learning models show strong correlation and good comparability with reference, with low bias though wide variability for deriving breathing metrics in asthma and health cohorts. Future efforts should focus on improvement of performance of these models, e.g., by increasing the size of the training dataset at the lower breathing rates.
BACKGROUND There has been a recent increased interest in monitoring health using wearable sensor technologies; however, few have focused on breathing. The ability to monitor breathing metrics may have indications both for general health as well as respiratory conditions such as asthma, where long-term monitoring of lung function has shown promising utility. OBJECTIVE In this paper, we explore a long short-term memory (LSTM) architecture and predict measures of interbreath intervals, respiratory rate, and the inspiration-expiration ratio from a photoplethysmogram signal. This serves as a proof-of-concept study of the applicability of a machine learning architecture to the derivation of respiratory metrics. METHODS A pulse oximeter was mounted to the left index finger of 9 healthy subjects who breathed at controlled respiratory rates. A respiratory band was used to collect a reference signal as a comparison. RESULTS Over a 40-second window, the LSTM model predicted a respiratory waveform through which breathing metrics could be derived with a bias value and 95% CI. Metrics included inspiration time (–0.16 seconds, –1.64 to 1.31 seconds), expiration time (0.09 seconds, –1.35 to 1.53 seconds), respiratory rate (0.12 breaths per minute, –2.13 to 2.37 breaths per minute), interbreath intervals (–0.07 seconds, –1.75 to 1.61 seconds), and the inspiration-expiration ratio (0.09, –0.66 to 0.84). CONCLUSIONS A trained LSTM model shows acceptable accuracy for deriving breathing metrics and could be useful for long-term breathing monitoring in health. Its utility in respiratory disease (eg, asthma) warrants further investigation.
BACKGROUND The ability to continuously monitor breathing metrics may have indications for general health as well as respiratory conditions such as asthma. However, few studies have focused on breathing due to a lack of available wearable technologies. OBJECTIVE Examine the performance of two machine learning algorithms in extracting breathing metrics from a finger-based pulse oximeter, which is amenable to long-term monitoring. METHODS Pulse oximetry data was collected from 11 healthy and 11 asthma subjects who breathed at a range of controlled respiratory rates. UNET and Long Short-Term memory (LSTM) algorithms were applied to the data, and results compared against breathing metrics derived from respiratory inductance plethysmography measured simultaneously as a reference. RESULTS The UNET vs LSTM model provided breathing metrics which were strongly correlated with those from the reference signal (all p<0.001, except for inspiratory:expiratory ratio). The following relative mean bias(95% confidence interval) were observed: inspiration time 1.89(-52.95, 56.74)% vs 1.30(-52.15, 54.74)%, expiration time -3.70(-55.21, 47.80)% vs -4.97(-56.84, 46.89)%, inspiratory:expiratory ratio -4.65(-87.18, 77.88)% vs -5.30(-87.07, 76.47)%, inter-breath intervals -2.39(-32.76, 27.97)% vs -3.16(-33.69, 27.36)%, and respiratory rate 2.99(-27.04 to 33.02)% vs 3.69(-27.17 to 34.56)%. CONCLUSIONS Both machine learning models show strongly correlation and good comparability with reference, with low bias though wide variability for deriving breathing metrics in asthma and health cohorts. Future efforts should focus on improvement of performance of these models, e.g. by increasing the size of the training dataset at the lower breathing rates. CLINICALTRIAL Sydney Local Health District Human Research Ethics Committee (#LNR\16\HAWKE99 ethics approval).