Alistair McEwan

Alistair McEwan

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2007 in Physiological Measurement
Verified
Journal Article
Closed access
Alistair McEwanAlistair McEwan
Alistair McEwan
GCG Cusick
G Cusick
DHdavid holder
david holder
Multi-frequency electrical impedance tomography (MFEIT) was proposed over 10 years ago as a potential spectroscopic impedance imaging method. At least seven systems have been developed for imaging the lung, heart, breast and brain, yet none has yet achieved clinical acceptance. While the absolute impedance varies considerably between different tissues, the changes in the spectrum due to physiological changes are expected to be quite small, especially when measured through a volume. This places substantial requirements on the MFEIT instrumentation to maintain a flat system frequency response over a broad frequency range (dc-MHz). In this work, the EIT measurement problem is described from a multi-frequency perspective. Solutions to the common problems are considered from recent MFEIT systems, and the debate over four-terminal or two-terminal (multiple source) architecture is revisited. An analysis of the sources of MFEIT errors identifies the major sources of error as stray capacitance and common-mode voltages which lead to a load dependence in the frequency response of MFEIT systems. A system that employs active electrodes appears to be the most able to cope with these errors (Li et al 1996). A distributed system with digitization at the electrode is suggested as a next step in MFEIT system development.

20 April 2006 in Physiological Measurement
Verified
Journal Article
Closed access
ARA Romsauerova
A Romsauerova
Alistair McEwanAlistair McEwan
Alistair McEwan
LHL Horesh
L Horesh
RYR Yerworth
R Yerworth
RBR H Bayford
R H Bayford
DHdavid holder
david holder
MFEIT (multi-frequency electrical impedance tomography) could distinguish between ischaemic and haemorrhagic stroke and permit the urgent use of thrombolytic drugs in patients with ischaemic stroke. The purpose of this study was to characterize the UCLH Mk 2 MFEIT system, designed for this purpose, with 32 electrodes and a multiplexed 2 kHz to 1.6 MHz single impedance measuring circuit. Data were collected in seven subjects with brain tumours, arteriovenous malformations or chronic stroke, as these resembled the changes in haemorrhagic or ischaemic stroke. Calibration studies indicated that the reliable bandwidth was only 16-64 kHz because of front-end components placed to permit simultaneous EEG recording. In raw in-phase component data, the SD of 16-64 kHz data for one electrode combination across subjects was 2.45 +/- 0.9%, compared to a largest predicted change of 0.35% estimated using the FEM of the head. Using newly developed methods of examining the most sensitive channels from the FEM, and nonlinear imaging constrained to the known site of the lesion, no reproducible changes between pathologies were observed. This study has identified a specification for accuracy in EITS in acute stroke, identified the size of variability in relation to this in human recordings, and presents new methods for analysis of data. Although no reproducible changes were identified, we hope this will provide a foundation for future studies in this demanding but potentially powerful novel application.

24 April 2012 in Physiological Measurement
Verified
Journal Article
Closed access
DND T Nguyen
D T Nguyen
CJC Jin
C Jin
ATA Thiagalingam
A Thiagalingam
Alistair McEwanAlistair McEwan
Alistair McEwan
Although electrical impedance tomography (EIT) for ventilation monitoring is on the verge of clinical trials, pulmonary perfusion imaging with EIT remains a challenge, especially in spontaneously breathing subjects. In anticipation of more research on this subject, we believe a thorough review is called for. In this paper, findings related to the physiological origins and electrical characteristics of this signal are summarized, highlighting properties that are particularly relevant to EIT. The perfusion impedance change signal is significantly smaller in amplitude compared with the changes due to ventilation. Therefore, the hardware used for this purpose must be more sensitive and more resilient to noise. In previous works, some signal- or image-processing methods have been required to separate these two signals. Three different techniques are reviewed in this paper, including the ECG-gating method, frequency-domain-filtering-based methods and a principal-component-analysis-based method. In addition, we review a number of experimental studies on both human and animal subjects that employed EIT for perfusion imaging, with promising results in the diagnosis of pulmonary embolism (PE) and pulmonary arterial hypertension as well as other potential applications. In our opinion, PE is most likely to become the main focus for perfusion EIT in the future, especially for heavily instrumented patients in the intensive care unit (ICU).

11 June 2013 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
HWHun Wi
Hun Wi
HSHarsh Sohal
Harsh Sohal
Alistair McEwanAlistair McEwan
Alistair McEwan
EWEung Je Woo
Eung Je Woo
TOTong In Oh
Tong In Oh
Electrical Impedance Tomography (EIT) is a safe medical imaging technology, requiring no ionizing or heating radiation, as opposed to most other imaging modalities. This has led to a clinical interest in its use for long-term monitoring, possibly at the bedside, for ventilation monitoring, bleeding detection, gastric emptying and epilepsy foci diagnosis. These long-term applications demand auto-calibration and high stability over long time periods. To address this need we have developed a new multi-frequency EIT system called the KHU Mark2.5 with automatic self-calibration and cooperation with other devices via a timing signal for synchronization with other medical instruments. The impedance measurement module (IMM) for flexible configuration as a key component includes an independent constant current source, an independent differential voltmeter, and a current source calibrator, which allows automatic self-calibration of the current source within each IMM. We installed a resistor phantom inside the KHU Mark2.5 EIT system for intra-channel and inter-channel calibrations of all voltmeters in multiple IMMs. We show the deterioration of performance of an EIT system over time and the improvement due to automatic self-calibration. The system is able to maintain SNR of 80 dB for frequencies up to 250 kHz and below 0.5% reciprocity error over continuous operation for 24 hours. Automatic calibration at least every 3 days is shown to maintain SNR above 75 dB and reciprocity error below 0.7% over 7 days at 1 kHz. A clear degradation in performance results with increasing time between automatic calibrations allowing the tailoring of calibration to suit the performance requirements of each application.

1 March 2012 in Applied Mathematical Modelling
Verified
Journal Article
Closed access
JTJ. Nasehi Tehrani
J. Nasehi Tehrani
Alistair McEwanAlistair McEwan
Alistair McEwan
CJC. Jin
C. Jin
ASAndre van Schaik
Andre van Schaik

24 April 2006 in Physiological Measurement
Verified
Journal Article
Closed access
Alistair McEwanAlistair McEwan
Alistair McEwan
ARA Romsauerova
A Romsauerova
RYR Yerworth
R Yerworth
LHL Horesh
L Horesh
RBR Bayford
R Bayford
DHdavid holder
david holder
A new, compact UCLH Mk 2.5 EIT system has been developed and calibrated for EIT imaging of the head. Improvements include increased input and output impedances, increased bandwidth and improved CMRR (80 dB) and linearity over frequencies and load (0.2% on a single channel, +/-0.7% on a saline tank over 20 Hz-256 kHz and 10-65 Omega). The accuracy of the system is sufficient to image severe acute stroke according to the specification from recent detailed anatomical modelling (Horesh et al 2005 3rd European Medical and Biological Engineering Conference EMBEC'05). A preliminary human study has validated the main specifications of the modelling, the range of trans-impedance from the head (8-70 Omega) using a 32 electrode, 258 combination protocol and contact impedances of 300 Omega to 2.7 kOmega over 20 Hz to 256 kHz.