Robbin Romijnders

Dr. Robbin Romijnders

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2021 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
RRRobbin Romijnders
Robbin Romijnders
EWElke Warmerdam
Elke Warmerdam
CHClint Hansen
Clint Hansen
JWJulius Welzel
Julius Welzel
GSGerhard Schmidt
Gerhard Schmidt
WMWalter Maetzler
Walter Maetzler
Background: Identification of individual gait events is essential for clinical gait analysis, because it can be used for diagnostic purposes or tracking disease progression in neurological diseases such as Parkinson’s disease. Previous research has shown that gait events can be detected from a shank-mounted inertial measurement unit (IMU), however detection performance was often evaluated only from straight-line walking. For use in daily life, the detection performance needs to be evaluated in curved walking and turning as well as in single-task and dual-task conditions. Methods: Participants (older adults, people with Parkinson’s disease, or people who had suffered from a stroke) performed three different walking trials: (1) straight-line walking, (2) slalom walking, (3) Stroop-and-walk trial. An optical motion capture system was used a reference system. Markers were attached to the heel and toe regions of the shoe, and participants wore IMUs on the lateral sides of both shanks. The angular velocity of the shank IMUs was used to detect instances of initial foot contact (IC) and final foot contact (FC), which were compared to reference values obtained from the marker trajectories. Results: The detection method showed high recall, precision and F1 scores in different populations for both initial contacts and final contacts during straight-line walking (IC: recall $$=$$ = 100%, precision $$=$$ = 100%, F1 score $$=$$ = 100%; FC: recall $$=$$ = 100%, precision $$=$$ = 100%, F1 score $$=$$ = 100%), slalom walking (IC: recall $$=$$ = 100%, precision $$\ge$$ ≥ 99%, F1 score $$=$$ = 100%; FC: recall $$=$$ = 100%, precision $$\ge$$ ≥ 99%, F1 score $$=$$ = 100%), and turning (IC: recall $$\ge$$ ≥ 85%, precision $$\ge$$ ≥ 95%, F1 score $$\ge$$ ≥ 91%; FC: recall $$\ge$$ ≥ 84%, precision $$\ge$$ ≥ 95%, F1 score $$\ge$$ ≥ 89%). Conclusions: Shank-mounted IMUs can be used to detect gait events during straight-line walking, slalom walking and turning. However, more false events were observed during turning and more events were missed during turning. For use in daily life we recommend identifying turning before extracting temporal gait parameters from identified gait events.

19 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
RRRobbin Romijnders
Robbin Romijnders
EWElke Warmerdam
Elke Warmerdam
Clint HansenClint Hansen
Clint Hansen
Gerhard SchmidtGerhard Schmidt
Gerhard Schmidt
WMWalter Maetzler
Walter Maetzler
Many algorithms use 3D accelerometer and/or gyroscope data from inertial measurement unit (IMU) sensors to detect gait events (i.e., initial and final foot contact). However, these algorithms often require knowledge about sensor orientation and use empirically derived thresholds. As alignment cannot always be controlled for in ambulatory assessments, methods are needed that require little knowledge on sensor location and orientation, e.g., a convolutional neural network-based deep learning model. Therefore, 157 participants from healthy and neurologically diseased cohorts walked 5 m distances at slow, preferred, and fast walking speed, while data were collected from IMUs on the left and right ankle and shank. Gait events were detected and stride parameters were extracted using a deep learning model and an optoelectronic motion capture (OMC) system for reference. The deep learning model consisted of convolutional layers using dilated convolutions, followed by two independent fully connected layers to predict whether a time step corresponded to the event of initial contact (IC) or final contact (FC), respectively. Results showed a high detection rate for both initial and final contacts across sensor locations (recall ≥92%, precision ≥97%). Time agreement was excellent as witnessed from the median time error (0.005 s) and corresponding inter-quartile range (0.020 s). The extracted stride-specific parameters were in good agreement with parameters derived from the OMC system (maximum mean difference 0.003 s and corresponding maximum limits of agreement (−0.049 s, 0.051 s) for a 95% confidence level). Thus, the deep learning approach was considered a valid approach for detecting gait events and extracting stride-specific parameters with little knowledge on exact IMU location and orientation in conditions with and without walking pathologies due to neurological diseases.

25 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JWJulius Welzel
Julius Welzel
DWDavid Wendtland
David Wendtland
EWElke Warmerdam
Elke Warmerdam
RRRobbin Romijnders
Robbin Romijnders
MEMorad Elshehabi
Morad Elshehabi
WMWalter Maetzler
Walter Maetzler
Current research on Parkinson’s disease (PD) is increasingly concerned with the identification of objective and specific markers to make reliable statements about the effect of therapy and disease progression. Parameters from inertial measurement units (IMUs) are objective and accurate, and thus an interesting option to be included in the regular assessment of these patients. In this study, 68 patients with PD (PwP) in Hoehn and Yahr (H&Y) stages 1–4 were assessed with two gait tasks—20 m straight walk and circular walk—using IMUs. In an ANCOVA model, we found a significant and large effect of the H&Y scores on step length in both tasks, and only a minor effect on step time. This study provides evidence that from the two potentially most important gait parameters currently accessible with wearable technology under supervised assessment strategies, step length changes substantially over the course of PD, while step time shows surprisingly little change in the progression of PD. These results show the importance of carefully evaluating quantitative gait parameters to make assumptions about disease progression, and the potential of the granular evaluation of symptoms such as gait deficits when monitoring chronic progressive diseases such as PD.

21 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
EWElke Warmerdam
Elke Warmerdam
RRRobbin Romijnders
Robbin Romijnders
JWJulius Welzel
Julius Welzel
Clint HansenClint Hansen
Clint Hansen
Gerhard SchmidtGerhard Schmidt
Gerhard Schmidt
WMWalter Maetzler
Walter Maetzler
Neurological pathologies can alter the swinging movement of the arms during walking. The quantification of arm swings has therefore a high clinical relevance. This study developed and validated a wearable sensor-based arm swing algorithm for healthy adults and patients with Parkinson’s disease (PwP). Arm swings of 15 healthy adults and 13 PwP were evaluated (i) with wearable sensors on each wrist while walking on a treadmill, and (ii) with reflective markers for optical motion capture fixed on top of the respective sensor for validation purposes. The gyroscope data from the wearable sensors were used to calculate several arm swing parameters, including amplitude and peak angular velocity. Arm swing amplitude and peak angular velocity were extracted with systematic errors ranging from 0.1 to 0.5° and from −0.3 to 0.3°/s, respectively. These extracted parameters were significantly different between healthy adults and PwP as expected based on the literature. An accurate algorithm was developed that can be used in both clinical and daily-living situations. This algorithm provides the basis for the use of wearable sensor-extracted arm swing parameters in healthy adults and patients with movement disorders such as Parkinson’s disease.

30 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
EWElke Warmerdam
Elke Warmerdam
RRRobbin Romijnders
Robbin Romijnders
JGJohanna Geritz
Johanna Geritz
MEMorad Elshehabi
Morad Elshehabi
CMCorina Maetzler
Corina Maetzler
Clint HansenClint Hansen
Clint Hansen
Healthy adults and neurological patients show unique mobility patterns over the course of their lifespan and disease. Quantifying these mobility patterns could support diagnosing, tracking disease progression and measuring response to treatment. This quantification can be done with wearable technology, such as inertial measurement units (IMUs). Before IMUs can be used to quantify mobility, algorithms need to be developed and validated with age and disease-specific datasets. This study proposes a protocol for a dataset that can be used to develop and validate IMU-based mobility algorithms for healthy adults (18–60 years), healthy older adults (>60 years), and patients with Parkinson’s disease, multiple sclerosis, a symptomatic stroke and chronic low back pain. All participants will be measured simultaneously with IMUs and a 3D optical motion capture system while performing standardized mobility tasks and non-standardized activities of daily living. Specific clinical scales and questionnaires will be collected. This study aims at building the largest dataset for the development and validation of IMU-based mobility algorithms for healthy adults and neurological patients. It is anticipated to provide this dataset for further research use and collaboration, with the ultimate goal to bring IMU-based mobility algorithms as quickly as possible into clinical trials and clinical routine.

Clint HansenClint Hansen
Clint Hansen
MBMaximilian Beckbauer
Maximilian Beckbauer
RRRobbin Romijnders
Robbin Romijnders
EWElke Warmerdam
Elke Warmerdam
JWJulius Welzel
Julius Welzel
WMWalter Maetzler
Walter Maetzler
Static balance is a commonly used health measure in clinical practice. Usually, static balance parameters are assessed via force plates or, more recently, with inertial measurement units (IMUs). Multiple parameters have been developed over the years to compare patient groups and understand changes over time. However, the day-to-day variability of these parameters using IMUs has not yet been tested in a neurogeriatric cohort. The aim of the study was to examine day-to-day variability of static balance parameters of five experimental conditions in a cohort of neurogeriatric patients using data extracted from a lower back-worn IMU. A group of 41 neurogeriatric participants (age: 78 ± 5 years) underwent static balance assessment on two occasions 12–24 h apart. Participants performed a side-by-side stance, a semi-tandem stance, a tandem stance on hard ground with eyes open, and a semi-tandem assessment on a soft surface with eyes open and closed for 30 s each. The intra-class correlation coefficient (two-way random, average of the k raters’ measurements, ICC2, k) and minimal detectable change at a 95% confidence level (MDC95%) were calculated for the sway area, velocity, acceleration, jerk, and frequency. Velocity, acceleration, and jerk were calculated in both anterior-posterior (AP) and medio-lateral (ML) directions. Nine to 41 participants could successfully perform the respective balance tasks. Considering all conditions, acceleration-related parameters in the AP and ML directions gave the highest ICC results. The MDC95% values for all parameters ranged from 39% to 220%, with frequency being the most consistent with values of 39–57%, followed by acceleration in the ML (43–55%) and AP direction (54–77%). The present results show moderate to poor ICC and MDC values for IMU-based static balance assessment in neurogeriatric patients. This suggests a limited reliability of these tasks and parameters, which should induce a careful selection of potential clinically relevant parameters.