Clint Hansen

Dr. Clint Hansen

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2020 in The Lancet Neurology
Verified
Journal Article
Closed access
EWElke Warmerdam
Elke Warmerdam
Jeffrey HausdorffJeffrey Hausdorff
Jeffrey Hausdorff
AAArash Atrsaei
Arash Atrsaei
YZYuhan Zhou
Yuhan Zhou
AMAnat Mirelman
Anat Mirelman
WMWalter Maetzler
Walter Maetzler

27 July 2019 in Annals of Neurology
Verified
Journal Article
Open access
Silvia Del DinSilvia Del Din
Silvia Del Din
MEMorad Elshehabi
Morad Elshehabi
BGBrook Galna
Brook Galna
MHMarkus A. Hobert
Markus A. Hobert
EWElke Warmerdam
Elke Warmerdam
WMWalter Maetzler
Walter Maetzler
Objective: Quantification of gait with wearable technology is promising; recent cross‐sectional studies showed that gait characteristics are potential prodromal markers for Parkinson disease (PD). The aim of this longitudinal prospective observational study was to establish gait impairments and trajectories in the prodromal phase of PD, identifying which gait characteristics are potentially early diagnostic markers of PD.Methods: The 696 healthy controls (mean age = 63 ± 7 years) recruited in the Tubingen Evaluation of Risk Factors for Early Detection of Neurodegeneration study were included. Assessments were performed longitudinally 4 times at 2‐year intervals, and people who converted to PD were identified. Participants were asked to walk at different speeds under single and dual tasking, with a wearable device placed on the lower back; 14 validated clinically relevant gait characteristics were quantified. Cox regression was used to examine whether gait at first visit could predict time to PD conversion after controlling for age and sex. Random effects linear mixed models (RELMs) were used to establish longitudinal trajectories of gait and model the latency between impaired gait and PD diagnosis.Results: Sixteen participants were diagnosed with PD on average 4.5 years after first visit (converters; PDC). Higher step time variability and asymmetry of all gait characteristics were associated with a shorter time to PD diagnosis. RELMs indicated that gait (lower pace) deviates from that of non‐PDC approximately 4 years prior to diagnosis.Interpretation: Together with other prodromal markers, quantitative gait characteristics can play an important role in identifying prodromal PD and progression within this phase. ANN NEUROL 2019;86:357–367

14 June 2023 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
MMM. Encarna Micó-Amigo
M. Encarna Micó-Amigo
TBTecla Bonci
Tecla Bonci
APAnisoara Paraschiv-Ionescu
Anisoara Paraschiv-Ionescu
MUMartin Ullrich
Martin Ullrich
CKCameron Kirk
Cameron Kirk
FCfor the Mobilise-D consortium
for the Mobilise-D consortium
Background: Although digital mobility outcomes (DMOs) can be readily calculated from real-world data collected with wearable devices and ad-hoc algorithms, technical validation is still required. The aim of this paper is to comparatively assess and validate DMOs estimated using real-world gait data from six different cohorts, focusing on gait sequence detection, foot initial contact detection (ICD), cadence (CAD) and stride length (SL) estimates. Methods: Twenty healthy older adults, 20 people with Parkinson’s disease, 20 with multiple sclerosis, 19 with proximal femoral fracture, 17 with chronic obstructive pulmonary disease and 12 with congestive heart failure were monitored for 2.5 h in the real-world, using a single wearable device worn on the lower back. A reference system combining inertial modules with distance sensors and pressure insoles was used for comparison of DMOs from the single wearable device. We assessed and validated three algorithms for gait sequence detection, four for ICD, three for CAD and four for SL by concurrently comparing their performances (e.g., accuracy, specificity, sensitivity, absolute and relative errors). Additionally, the effects of walking bout (WB) speed and duration on algorithm performance were investigated. Results: We identified two cohort-specific top performing algorithms for gait sequence detection and CAD, and a single best for ICD and SL. Best gait sequence detection algorithms showed good performances (sensitivity > 0.73, positive predictive values > 0.75, specificity > 0.95, accuracy > 0.94). ICD and CAD algorithms presented excellent results, with sensitivity > 0.79, positive predictive values > 0.89 and relative errors < 11% for ICD and < 8.5% for CAD. The best identified SL algorithm showed lower performances than other DMOs (absolute error < 0.21 m). Lower performances across all DMOs were found for the cohort with most severe gait impairments (proximal femoral fracture). Algorithms’ performances were lower for short walking bouts; slower gait speeds (< 0.5 m/s) resulted in reduced performance of the CAD and SL algorithms. Conclusions: Overall, the identified algorithms enabled a robust estimation of key DMOs. Our findings showed that the choice of algorithm for estimation of gait sequence detection and CAD should be cohort-specific (e.g., slow walkers and with gait impairments). Short walking bout length and slow walking speed worsened algorithms’ performances. Trial registration ISRCTN – 12246987.

2 December 2021 in BMJ Open
Verified
Journal Article
Open access
PDF file
Claudia MazzàClaudia Mazzà
Claudia Mazzà
LALisa Alcock
Lisa Alcock
KAKamiar Aminian
Kamiar Aminian
CBClemens Becker
Clemens Becker
SBStefano Bertuletti
Stefano Bertuletti
LRLynn Rochester
Lynn Rochester
Introduction Existing mobility endpoints based on functional performance, physical assessments and patient self-reporting are often affected by lack of sensitivity, limiting their utility in clinical practice. Wearable devices including inertial measurement units (IMUs) can overcome these limitations by quantifying digital mobility outcomes (DMOs) both during supervised structured assessments and in real-world conditions. The validity of IMU-based methods in the real-world, however, is still limited in patient populations. Rigorous validation procedures should cover the device metrological verification, the validation of the algorithms for the DMOs computation specifically for the population of interest and in daily life situations, and the users’ perspective on the device. Methods and analysis This protocol was designed to establish the technical validity and patient acceptability of the approach used to quantify digital mobility in the real world by Mobilise-D, a consortium funded by the European Union (EU) as part of the Innovative Medicine Initiative, aiming at fostering regulatory approval and clinical adoption of DMOs. After defining the procedures for the metrological verification of an IMU-based device, the experimental procedures for the validation of algorithms used to calculate the DMOs are presented. These include laboratory and real-world assessment in 120 participants from five groups: healthy older adults; chronic obstructive pulmonary disease, Parkinson’s disease, multiple sclerosis, proximal femoral fracture and congestive heart failure. DMOs extracted from the monitoring device will be compared with those from different reference systems, chosen according to the contexts of observation. Questionnaires and interviews will evaluate the users’ perspective on the deployed technology and relevance of the mobility assessment. Ethics and dissemination The study has been granted ethics approval by the centre’s committees (London—Bloomsbury Research Ethics committee; Helsinki Committee, Tel Aviv Sourasky Medical Centre; Medical Faculties of The University of Tübingen and of the University of Kiel). Data and algorithms will be made publicly available. Trial registration number ISRCTN (12246987).

4 September 2017 in Frontiers in Neurology
Verified
Journal Article
Open access
MPMinh H. Pham
Minh H. Pham
MEMorad Elshehabi
Morad Elshehabi
LHLinda Haertner
Linda Haertner
Silvia Del DinSilvia Del Din
Silvia Del Din
KSKarin Srulijes
Karin Srulijes
WMWalter Maetzler
Walter Maetzler
Introduction: Inertial measurement units (IMUs) positioned on various body locations allow detailed gait analysis even under unconstrained conditions. From a medical perspective, the assessment of vulnerable populations is of particular relevance, especially in the daily-life environment. Gait analysis algorithms need thorough validation, as many chronic diseases show specific and even unique gait patterns. The aim of this study was therefore to validate an acceleration-based step detection algorithm for patients with Parkinson’s disease (PD) and older adults in both a lab-based and home-like environment. Methods: In this prospective observational study, data was captured from a single 6-degrees of freedom IMU (APDM) (3-DOF accelerometer and 3-DOF gyroscope) worn on the lower back. Detection of heel strike (HS) and toe off (TO) on a treadmill was validated against an optoelectronic system (Vicon) (11 PD patients and 12 older adults). A second independent validation study in the home-like environment was performed against video observation (20 PD patients and 12 older adults) and included step counting during turning and non-turning, defined with a previously published algorithm. Results: A continuous-wavelet-transform (cwt) based algorithm was developed for step detection with very high agreement with the optoelectronic system. HS detection in PD patients/older adults, respectively, reached 99%/99% accuracy. Similar results were obtained for TO (99%/100%). In HS detection, Bland-Altman plots showed a mean difference of 0.002s (95% Confidence Interval (CI) -0.09 to 0.10) between the algorithm and the optoelectronic system. The Bland-Altman plot for TO detection showed mean differences of 0.00s (95% CI -0.12 to 0.12). In the home-like assessment, the algorithm for detection of occurrence of steps during turning reached 90% (PD patients)/90% (older adults) sensitivity, 83%/88% specificity and 88%/89% accuracy. The detection of steps during non-turning phases reached 91%/91% sensitivity, 90%/90% specificity and 91%/91% accuracy. Conclusion: This continuous-wavelet-transform based algorithm for step detection from accelerations measured at the lower back is in high agreement with the optoelectronic system in both PD patients and older adults. This approach and algorithm thus could provide a valuable tool for future research on home-based gait analysis in these vulnerable cohorts.

14 October 2021 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
APAshley Polhemus
Ashley Polhemus
LDLaura Delgado-Ortiz
Laura Delgado-Ortiz
GBGavin Brittain
Gavin Brittain
NCNikolaos Chynkiamis
Nikolaos Chynkiamis
FSFrancesca Salis
Francesca Salis
MDMobilise- D
Mobilise- D
Physical mobility is essential to health, and patients often rate it as a high-priority clinical outcome. Digital mobility outcomes (DMOs), such as real-world gait speed or step count, show promise as clinical measures in many medical conditions. However, current research is nascent and fragmented by discipline. This scoping review maps existing evidence on the clinical utility of DMOs, identifying commonalities across traditional disciplinary divides. In November 2019, 11 databases were searched for records investigating the validity and responsiveness of 34 DMOs in four diverse medical conditions (Parkinson’s disease, multiple sclerosis, chronic obstructive pulmonary disease, hip fracture). Searches yielded 19,672 unique records. After screening, 855 records representing 775 studies were included and charted in systematic maps. Studies frequently investigated gait speed (70.4% of studies), step length (30.7%), cadence (21.4%), and daily step count (20.7%). They studied differences between healthy and pathological gait (36.4%), associations between DMOs and clinical measures (48.8%) or outcomes (4.3%), and responsiveness to interventions (26.8%). Gait speed, step length, cadence, step time and step count exhibited consistent evidence of validity and responsiveness in multiple conditions, although the evidence was inconsistent or lacking for other DMOs. If DMOs are to be adopted as mainstream tools, further work is needed to establish their predictive validity, responsiveness, and ecological validity. Cross-disciplinary efforts to align methodology and validate DMOs may facilitate their adoption into clinical practice.