Sahba Sadir

Dr. Sahba Sadir

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in BioMed Research International
Verified
Journal Article
Open access
PDF file
RMRadha S. P. Malon
Radha S. P. Malon
SSSahba Sadir
Sahba Sadir
MMM. B. Malarvili
M. B. Malarvili
ECEmma P. Córcoles
Emma P. Córcoles
Saliva is increasingly recognised as an attractive diagnostic fluid. The presence of various disease signalling salivary biomarkers that accurately reflect normal and disease states in humans and the sampling benefits compared to blood sampling are some of the reasons for this recognition. This explains the burgeoning research field in assay developments and technological advancements for the detection of various salivary biomarkers to improve clinical diagnosis, management, and treatment. This paper reviews the significance of salivary biomarkers for clinical diagnosis and therapeutic applications, with focus on the technologies and biosensing platforms that have been reported for screening these biomarkers.

13 March 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
KAKhaled Alsabbagh
Khaled Alsabbagh
THTim Hornung
Tim Hornung
AVAchim Voigt
Achim Voigt
SSSahba Sadir
Sahba Sadir
TRTaleieh Rajabi
Taleieh Rajabi
KLKerstin Länge
Kerstin Länge
A microfluidic chip for electrochemical impedance spectroscopy (EIS) is presented as bio-sensor for label-free detection of proteins by using the example of cardiac troponin I. Troponin I is one of the most specific diagnostic serum biomarkers for myocardial infarction. The microfluidic impedance biosensor chip presented here consists of a microscope glass slide serving as base plate, sputtered electrodes, and a polydimethylsiloxane (PDMS) microchannel. Electrode functionalization protocols were developed considering a possible charge transfer through the sensing layer, in addition to analyte-specific binding by corresponding antibodies and reduction of nonspecific protein adsorption to prevent false-positive signals. Reagents tested for self-assembled monolayers (SAMs) on gold electrodes included thiolated hydrocarbons and thiolated oligonucleotides, where SAMs based on the latter showed a better performance. The corresponding antibody was covalently coupled on the SAM using carbodiimide chemistry. Sampling and measurement took only a few minutes. Application of a human serum albumin (HSA) sample, 1000 ng/mL, led to negligible impedance changes, while application of a troponin I sample, 1 ng/mL, led to a significant shift in the Nyquist plot. The results are promising regarding specific detection of clinically relevant concentrations of biomarkers, such as cardiac markers, with the newly developed microfluidic impedance biosensor chip.

7 December 2020 in Energies
Verified
Journal Article
Open access
PDF file
MTMohammadmahdi Talebi
Mohammadmahdi Talebi
SSSahba Sadir
Sahba Sadir
Manfred KrautManfred Kraut
Manfred Kraut
RDRoland Dittmeyer
Roland Dittmeyer
PWPeter Woias
Peter Woias
Determination of local heat transfer coefficient at the interface of channel wall and fluid was the main goal of this experimental study in microchannel flow boiling domain. Flow boiling heat transfer to DI-water in a single microchannel with a rectangular cross section was experimentally investigated. The rectangular cross section dimensions of the experimented microchannel were 1050 μm × 500 μm and 1500 μm × 500 μm. Experiments under conditions of boiling were performed in a test setup, which allows the optical and local impedance measurements of the fluids by mass fluxes of 22.1 kg·m−2·s−1 to 118.8 kg·m−2·s−1 and heat fluxes in the range of 14.7 kW·m−2 to 116.54 kW·m−2. The effect of the mass flux, heat flux, and flow pattern on flow boiling local heat transfer coefficient and pressure drop were investigated. Experimental data compared to existing correlations indicated no single correlation of good predictive value. This was concluded to be the case due to the instability of flow conditions on one hand and the variation of the flow regimes over the experimental conditions on the other hand. The results from the local impedance measurements in correlation to the optical measurements shows the flow regime variation at the experimental conditions. From these measurements, useful parameters for use in models on boiling like the 3-zone model were shown. It was shown that the sensing method can shed a precise light on unknown features locally in slug flow such as residence time of each phases, bubble frequency, and duty cycle.

18 November 2019 in Proceedings in Applied Mathematics and Mechanics
Verified
Journal Article
Open access
PDF file
SSSahba Sadir
Sahba Sadir
MTMohammadmahdi Talebi
Mohammadmahdi Talebi
PWPeter Woias
Peter Woias
RDRoland Dittmeyer
Roland Dittmeyer
BFBettina Frohnapfel
Bettina Frohnapfel
ASAlexander Stroh
Alexander Stroh
In this study, we model the heat transfer mechanism for a single nucleate vapor bubble which then expands to an elongated bubble during evaporation in a microchannel. The model is a logical mix of empirical correlations and analytical models and is defined for the two steps of bubble growth including: (a) partially confined growth, in which the bubble expands from nucleation site until it fills the entire cross‐section of the channel, and (b) fully confined growth, in which the bubble reaches the side walls and begins to elongate axially in downstream direction. To estimate the heat transfer characteristics of vapor bubble growth during evaporation in the microchannel, the time variation of liquid film thickness and bubble nose position are evaluated. Finally, a time‐averaged value of local heat transfer coefficient is obtained for a period of time using available heat transfer correlations for each heat transfer process separately.

1 January 2021 in Journal of Fluid Flow, Heat and Mass Transfer
Verified
Journal Article
Open access
SSSahba Sadir
Sahba Sadir
CSChristoph Spiegel
Christoph Spiegel
WAWolfgang Augustin
Wolfgang Augustin
SSStephan Erich Scholl
Stephan Erich Scholl
Manfred KrautManfred Kraut
Manfred Kraut
The Volume 8, published for JFFHMT Journal.

2 November 2020 in Proceedings
Verified
Conference Paper
Open access
PDF file
KAKhaled Alsabbagh
Khaled Alsabbagh
THTim Hornung
Tim Hornung
AVAchim Voigt
Achim Voigt
SSSahba Sadir
Sahba Sadir
TRTaleieh Rajabi
Taleieh Rajabi
KLKerstin Länge
Kerstin Länge
A microfluidic chip for electrochemical impedance spectroscopy (EIS) is presented as biosensor for the detection of cardiac troponin I (cTnI). Troponin I is one of the most specific diagnostic serum biomarkers for myocardial infarction. As impedimetric biosensors allow direct and label-free analyte detection, they are particularly suitable for fast biomarker detection. This is essential in the diagnosis of cardiac infarctions to enable an early treatment promoting a positive outcome. The microfluidic impedance biosensor chip presented here consists of a microscope glass slide serving as base plate, sputtered electrodes, and a polydimethylsiloxane (PDMS) microchannel. Electrode functionalization protocols were developed considering a low initial impedance in addition to analyte-specific binding by corresponding antibodies and reduction of non-specific protein adsorption to prevent false-positive signals. Reagents tested for self-assembled monolayers (SAMs) on gold electrodes included thiolated hydrocarbons and thiolated oligonucleotides, where SAMs based on the latter showed a better performance. The corresponding antibody (anti-cTnI) was covalently coupled on the SAM using carbodiimide chemistry. The PDMS microchannel was bonded on the glass slide with the functionalized electrodes, and the completed microfluidic impedance biosensor chip was connected to the readout system. Sampling and measurement took only a few minutes. Application of a human serum albumin (HSA) sample, 1000 ng/mL, led to negligible signal changes, while application of a troponin I sample, 1 ng/mL, led to a significant signal shift in the Nyquist plot. The results are promising regarding specific detection of clinically relevant concentrations of cardiac markers with the newly developed impedance biosensor chip.