Faezeh Shanehsazzadeh

Dr. Faezeh Shanehsazzadeh

Sharif University of Technology, Tehran, Iran.
+1
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2017 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
FSFaezeh Shanehsazzadeh
Faezeh Shanehsazzadeh
FFFaezeh Fardmanesh
Faezeh Fardmanesh
light weight and low-cost active magnetic shield sys-tem is proposed for a single channel SQUID-based magnetocardiog-raphy system equipped for operating at liquid nitrogen temperature without passive magnetic shield. The developed active shield, using coils around the sensors, is a two-stage magnetic shielding system, each stage of which has been designed to compensate different fre-quency and dynamic ranges. The sensor part contains two high-Tc rf-SQUID magnetometers, capable of working stably under earth magnetic field, placed in an axial gradiometric arrangement with a baseline of 10 cm. The active shield setup is driven using two corre-lated proportional-integral-derivative closed loop systems. In the de-signed system, the coils are in the vicinity of the SQUIDs, resulting in coupling the coils to the SQUIDs as well as to the resonators. Hence, the impedance of the coils along with the phase of the feedback current is affected based on the configuration. In this paper, investigation of the shielding performance of our bi-stage mag-netic shield as the active compensation, fed by the optimal feedback control system with all the above considerations, is reported. Using the designed shielding system, the disturbing magnetic signals could be attenuated such that the pico-Tesla signals could be obtained.

29 May 2018 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
BRBehnoush Rostami
Behnoush Rostami
FSFaezeh Shanehsazzadeh
Faezeh Shanehsazzadeh
FFFaezeh Fardmanesh
Faezeh Fardmanesh
We present a new approach for depth detection of hidden defects based on the analysis of the frequency spectrum of the output waveform in a nondestructive testing (NDT) system. In our eddy current (EC) SQUID based NDT system, we apply multiple frequencies to its single excitation coil in a magnetically unshielded environment. The excitation coil is a planar D-shaped printed circuit board coil, and a high-Tc gradiometer YBCO rf-SQUID is used as the electromagnetic sensor in this system. An automated two-dimensional non-magnetic scanning robot is used to test samples with intentional defects at different depths. In this approach, a diagram labeled "FFT relative changes" is assigned to each test sample. The optimum points of the FFT relative changes diagram occur at the optimum frequencies directly related to the depth of the corresponding defects. The relation between the optimum frequency and the corresponding depth in our system is obtained both experimentally and by simulation. An excellent agreement between the practical and the simulation results confirmed the accuracy of the proposed method.

17 July 2018 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
TJTahereh Jabbari
Tahereh Jabbari
FSFaezeh Shanehsazzadeh
Faezeh Shanehsazzadeh
HZHesam Zandi
Hesam Zandi
MBMarko Banzet
Marko Banzet
JSJuergen Schubert
Juergen Schubert
FFFaezeh Fardmanesh
Faezeh Fardmanesh
We have investigated various geometrical design dependencies for RSFQ circuits in High-Tc Superconductors (HTS) technology, including the characteristics of the intermediate inductances. Structural and temporal dependent combinations of Cn-Rn (capacitance and normal resistance of the Josephson junctions JJs) in the HTS technology are also investigated. Relatively favorable combinations of normal resistance and low capacitance of the JJs needed in the HTS technology for RSFQ circuits have been made possible by recent fabrication methods of high quality YBCO films. Obtaining these devices is made achievable due to emphasizing the grain boundary structures and engineering the aspect of high critical current density (JC) of the HTS JJs. Mutual interactions of the intermediate inductances with other parts of the whole circuit are examined and optimized for the best operation situation. Here in particular, the operation of the HTS Josephson-transmission-line (JTL) cells utilizing the grain boundary Josephson junctions, including various structural inductances, is studied based on the reported parameters of the developed devices and thoroughly analyzed by simulation results.

17 November 2016 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
FSFaezeh Shanehsazzadeh
Faezeh Shanehsazzadeh
TJTahereh Jabbari
Tahereh Jabbari
FQFatemeh Qaderi
Fatemeh Qaderi
FFFaezeh Fardmanesh
Faezeh Fardmanesh
We propose a new design for monolayer superconducting planar flux transformer integrated with a coplanar resonator serving as a GHz range tank circuit for high-Tc rf-SQUID magnetometers. Based on the proposed design, which is optimized using the finite element method (FEM), the transformer-resonator configuration is made of 200 nm thick monolayer YBCO film on a crystalline LaAlO3 substrate. In this optimized design, the SQUID magnetometer is coupled through flip-chip configuration with the configuration providing high coupling coefficient between the devices. The design permits coupling of the rf signals to the SQUID efficiently whereas the transformer is designed to couple the dc to low frequency magnetic field signals to the SQUID without disturbing the rf excitation. By means of split-ring resonator structure and also a SrTiO3 layer on the back side of the configuration, tuning the resonance frequency with high precision could be made possible using minimum change in the design. Loaded quality factor and the coupling coefficient of the designed resonator are obtained to be high to meet the SQUID system requirements very well. Also, lower field-to-flux transformation coefficient is achieved by using our single-turn transformer design compared to that of the bare SQUID.

17 August 2017 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
FSFaezeh Shanehsazzadeh
Faezeh Shanehsazzadeh
NKNafise Kalantari
Nafise Kalantari
FSFarrokh Sarreshtedari
Farrokh Sarreshtedari
MFMehdi Fardmanesh
Mehdi Fardmanesh
An active noise cancellation method is proposed for superconducting quantum interference devices (SQUID)-based magnetocardiography systems working out of magnetically shielded rooms. Using YBCO high-Tc rf-SQUID magnetometers as magnetic field sensors, an active shielding system was implemented based on this method. This method incorporates two different shielding frequency regimes of operation simultaneously. This is because the unwanted background magnetic field signals range from very low frequencies up to high frequencies with a wide range of amplitudes at the upper and lower frequency spectra. Therefore, the shielding system is designed in a bistage configuration, and each stage covers one part of the frequency spectrum. Each shielding stage is based on a coil designed and optimized by finite element method calculations. One of the coils is used for compensating high amplitude and very low frequency (0-0.1 Hz) far-field environmental magnetic field noise, and the second one is used for relatively low amplitude and higher frequency (0.1-100 Hz) magnetic field noise. Because of these frequency and amplitude characteristics, each coil uses independent control circuit. For designing the controllers, methods based on the dynamic model approximation of the first and second orders were examined, which led to optimized proportional-integral-derivative controllers. The shielding efficiency of the proposed bistage active shielding system shows a significant improved effectiveness compared to that of the conventional one stage active shielding systems.

1 March 2016 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
PDF file
NKNafise Kalantari
Nafise Kalantari
FSFaezeh Shanehsazzadeh
Faezeh Shanehsazzadeh
FSFarrokh Sarreshtedari
Farrokh Sarreshtedari
MFMehdi Fardmanesh
Mehdi Fardmanesh
Characteristics of a lumped element L-C tank circuit resonator of high-Tc rf-SQUIDs, which plays an important role in the device operation, have been experimentally investigated, according to the corresponding simulations obtained by COMSOL Multiphysics. We experimentally investigated the characteristics of the resonators by measuring their scattering parameters, as well as evaluating the rf-SQUID signal. Our SQUIDs are made of sputtered YBCO thin films with 3-mm-diameter washer areas. Different configurations of the resonator are investigated, and it is observed that, by increasing the thickness of the dielectric in a specific range, the reflection coefficient (S11) increases. For the experimental verifications, we constructed resonators with different dielectric thicknesses and different configurations. The resonators are made of a dielectric board with a hole in its middle to hold the inductors for close coupling to the SQUID mounted on the backside. An increase in the thickness of the dielectric board confines the RF field distribution close to the SQUID, while also making further distance between the contact pads and the SQUID reducing their parasitic effects on the device signal. This is observed to improve the stability of the operating point of the SQUIDs, while also reducing the noise for measured frequency range of 0.1 to 100 Hz.