Behnoush Rostami

Ms. Behnoush Rostami

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2018 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
BRBehnoush Rostami
Behnoush Rostami
FSFaezeh Shanehsazzadeh
Faezeh Shanehsazzadeh
FFFaezeh Fardmanesh
Faezeh Fardmanesh
We present a new approach for depth detection of hidden defects based on the analysis of the frequency spectrum of the output waveform in a nondestructive testing (NDT) system. In our eddy current (EC) SQUID based NDT system, we apply multiple frequencies to its single excitation coil in a magnetically unshielded environment. The excitation coil is a planar D-shaped printed circuit board coil, and a high-Tc gradiometer YBCO rf-SQUID is used as the electromagnetic sensor in this system. An automated two-dimensional non-magnetic scanning robot is used to test samples with intentional defects at different depths. In this approach, a diagram labeled "FFT relative changes" is assigned to each test sample. The optimum points of the FFT relative changes diagram occur at the optimum frequencies directly related to the depth of the corresponding defects. The relation between the optimum frequency and the corresponding depth in our system is obtained both experimentally and by simulation. An excellent agreement between the practical and the simulation results confirmed the accuracy of the proposed method.

1 September 2019 in Engineering Research Express
Verified
Journal Article
Closed access
PDF file
BRBehnoush Rostami
Behnoush Rostami
SMSeyed Iman Mirzaei
Seyed Iman Mirzaei
AZAtieh Zamani
Atieh Zamani
ASAbdolreza Simchi
Abdolreza Simchi
MFMehdi Fardmanesh
Mehdi Fardmanesh
We have developed a new low-cost method for fabrication of an enhanced porosity ultra-low noise silver-silver chloride (Ag-AgCl) reference electrode with dramatically high stability, useful in precise electrochemical and biomedical measurements. Low noise level and high stability are the most important features when evaluating reference electrode for example when used as a half-cell at electrochemical cells. The noise was measured for bare Ag-AgCl electrode pairs in a saline electrolyte without any junction. The noise spectral density for such measurements increases at low frequencies due to flicker (1/f) noise. Thermal noise from the real part of the electrode impedance is always lower than 1/f noise and is shown as offset voltage in noise spectrum. Electrode noise is highly correlated to its offset voltage. Moreover, the variance of the potential difference in our measurements is correlated to the noise level of electrodes. In this paper, offset voltage spectrum and the variance of data while doing measurements are proposed for identification of noise in our electrodes. The results presented suggest a new low-cost process for fabrication of enhanced porosity reference electrodes with nanovolt noise level at 1 Hz, low enough for electrochemical and biomedical measurements.