DOMINIQUE FORTUNE

Mr. DOMINIQUE FORTUNE

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Daniela IstrateDaniela Istrate
Daniela Istrate
AKAbderrahim Khamlichi
Abderrahim Khamlichi
SSSoureche Soccalingame
Soureche Soccalingame
JRJorge ROVIRA
Jorge ROVIRA
DFDOMINIQUE FORTUNE
DOMINIQUE FORTUNE
FGFernando Garnacho
Fernando Garnacho
Current standard EN 50463-2 indicates the tests and the requirements to be satisfied for an energy measurement system of a traction unit for railway applications. Some of these tests are to be done with several harmonics superposed on the rated voltage, respectively current. However, no calibration systems satisfying the standard requirements were available few years ago. The work performed in the EURAMET project “MyRailS” leads to the development of fictive power sources and reference measurement systems described in this paper. Therefore, it is possible to generate distorted 25 kV-50 Hz voltages with harmonics up to 5 kHz and 90° phase-fired currents up to 500 A with harmonics up to 5 kHz. The generated power is measured by developed traceable reference systems with accuracy better than 0.5%.