Toru Ide

Dr. Toru Ide


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HYHiroaki Yokota
Hiroaki Yokota
AFAtsuhito Fukasawa
Atsuhito Fukasawa
MHMinako Hirano
Minako Hirano
TIToru Ide
Toru Ide
Over the years, fluorescence microscopy has evolved and has become a necessary element of life science studies. Microscopy has elucidated biological processes in live cells and organisms, and also enabled tracking of biomolecules in real time. Development of highly sensitive photodetectors and light sources, in addition to the evolution of various illumination methods and fluorophores, has helped microscopy acquire single-molecule fluorescence sensitivity, enabling single-molecule fluorescence imaging and detection. Low-light photodetectors used in microscopy are classified into two categories: point photodetectors and wide-field photodetectors. Although point photodetectors, notably photomultiplier tubes (PMTs), have been commonly used in laser scanning microscopy (LSM) with a confocal illumination setup, wide-field photodetectors, such as electron-multiplying charge-coupled devices (EMCCDs) and scientific complementary metal-oxide-semiconductor (sCMOS) cameras have been used in fluorescence imaging. This review focuses on the former low-light point photodetectors and presents their fluorescence microscopy applications and recent progress. These photodetectors include conventional PMTs, single photon avalanche diodes (SPADs), hybrid photodetectors (HPDs), in addition to newly emerging photodetectors, such as silicon photomultipliers (SiPMs) (also known as multi-pixel photon counters (MPPCs)) and superconducting nanowire single photon detectors (SSPDs). In particular, this review shows distinctive features of HPD and application of HPD to wide-field single-molecule fluorescence detection.

10 December 2016 in Analytical Sciences
Verified
Journal Article
Open access
PDF file
DODaichi Okuno
Daichi Okuno
MHMinako Hirano
Minako Hirano
HYHiroaki Yokota
Hiroaki Yokota
YOYukiko Onishi
Yukiko Onishi
JIJunya Ichinose
Junya Ichinose
TIToru Ide
Toru Ide
The artificial bilayer single-channel recording technique is commonly used to observe detailed pharmacological properties of various ion channel proteins. It permits easy control of the solution and membrane lipid composition, and is also compatible with pharmacological screening devices. However, its use is limited due to low measurement efficiency. Here, we develop a novel artificial bilayer single-channel recording technique in which bilayers are made and channels are reconstituted into the membranes by contacting a gold electrode to the lipid-solution interface. Using this technique, we measured the single-channel currents of two channel-forming peptides, gramicidin and alamethicin, and a channel-forming protein, α-hemolysin. This technique requires only one action, allowing the technique to potentially be combined with high-throughput screening devices.

23 January 2018 in Nanoscale
Verified
Journal Article
Closed access
PDF file
DODaichi Okuno
Daichi Okuno
MHMinako Hirano
Minako Hirano
HYHiroaki Yokota
Hiroaki Yokota
JIJunya Ichinose
Junya Ichinose
TKTakamitsu Kira
Takamitsu Kira
TIToru Ide
Toru Ide
A single ion-channel protein on a gold nano-electrode was inserted into an artificial membrane and its current was recorded.

1 December 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
MHMinako Hirano
Minako Hirano
DYDaiki Yamamoto
Daiki Yamamoto
MAMami Asakura
Mami Asakura
THTohru Hayakawa
Tohru Hayakawa
SMShintaro Mise
Shintaro Mise
TIToru Ide
Toru Ide
Ion channel proteins play important roles in various cell functions, making them attractive drug targets. Artificial lipid bilayer recording is a technique used to measure the ion transport activities of channel proteins with high sensitivity and accuracy. However, the measurement efficiency is low. In order to improve the efficiency, we developed a method that allows us to form bilayers on a hydrogel bead and record channel currents promptly. We tested our system by measuring the activities of various types of channels, including gramicidin, alamethicin, α-hemolysin, a voltage-dependent anion channel 1 (VDAC1), a voltage- and calcium-activated large conductance potassium channel (BK channel), and a potassium channel from Streptomyces lividans (KcsA channel). We confirmed the ability for enhanced measurement efficiency and measurement system miniaturizion.

1 August 2014 in Biochemical and Biophysical Research Communications
Verified
Journal Article
Closed access
MHMinako Hirano
Minako Hirano
DODaichi Okuno
Daichi Okuno
YOYukiko Onishi
Yukiko Onishi
TIToru Ide
Toru Ide

1 February 2008 in Bioorganic & Medicinal Chemistry Letters
Verified
Journal Article
Closed access
KFKenzo Fujimoto
Kenzo Fujimoto
YYYoshinaga Yoshimura
Yoshinaga Yoshimura
MIMakoto Ihara
Makoto Ihara
KMKazuhiko Matsuda
Kazuhiko Matsuda
YTYuko Takeuchi
Yuko Takeuchi
TIToru Ide
Toru Ide