Over the years, fluorescence microscopy has evolved and has become a necessary element of life science studies. Microscopy has elucidated biological processes in live cells and organisms, and also enabled tracking of biomolecules in real time. Development of highly sensitive photodetectors and light sources, in addition to the evolution of various illumination methods and fluorophores, has helped microscopy acquire single-molecule fluorescence sensitivity, enabling single-molecule fluorescence imaging and detection. Low-light photodetectors used in microscopy are classified into two categories: point photodetectors and wide-field photodetectors. Although point photodetectors, notably photomultiplier tubes (PMTs), have been commonly used in laser scanning microscopy (LSM) with a confocal illumination setup, wide-field photodetectors, such as electron-multiplying charge-coupled devices (EMCCDs) and scientific complementary metal-oxide-semiconductor (sCMOS) cameras have been used in fluorescence imaging. This review focuses on the former low-light point photodetectors and presents their fluorescence microscopy applications and recent progress. These photodetectors include conventional PMTs, single photon avalanche diodes (SPADs), hybrid photodetectors (HPDs), in addition to newly emerging photodetectors, such as silicon photomultipliers (SiPMs) (also known as multi-pixel photon counters (MPPCs)) and superconducting nanowire single photon detectors (SSPDs). In particular, this review shows distinctive features of HPD and application of HPD to wide-field single-molecule fluorescence detection.
To obtain bonded structure with a low residual stress and a low attenuation for longitudinal leaky surface acoustic waves (LLSAWs), the propagation and resonance properties of an LLSAW on an amorphous layer inserted between LiNbO3 (LN) thin plate and an X-cut quartz substrate were theoretically analyzed. The attenuation of LLSAW on the metallized surface of an X-cut 36°Y-propagating LN (X36°Y-LN)/Al2O3/X35°Y-quartz structure was calculated to be 0.0001 dB/λ at the normalized LN thin-plate thickness h/λ=0.072 (λ: wavelength) and was lower than that on an X36°Y-LN/X35°Y-quartz structure. Using a finite element method (FEM) system for analysis, for the X36°Y-LN/Al2O3/X35°Y-quartz model, we found that the Q factor was improved to 82,000 from 15,000 for the X36°Y-LN/X35°Y-Q model. It is considered that the attenuation was reduced by the suppression of the leakage of the shear vertical component when the Al2O3 layer was inserted. For the same structure, but in which the mechanical loss Qm of 1,000 for LN was assumed, the Q factor was determined to be 2,500 and 1,900 with and without an inserted amorphous Al2O3 layer, respectively.
This study investigated the effect of a caries-detecting solution on the tensile bond strength (TBS) to sound bovine dentin - which was either rinsed thoroughly of or contaminated with the caries-detecting solution. Caries Detector (1.0% acid red in propylene glycol) was applied on flat dentin surfaces for 10 seconds, rinsed, and dried with syringe air. In another group, Caries Detector was not rinsed but air-dried. Then, the surfaces were treated with one of the following adhesive systems: Clearfil Protect Bond, Clearfil SE Bond, One-Up Bond F, or Single Bond. Furthermore, an ingredient of Caries Detector, either 1.0% acid red aqueous solution or propylene glycol, was applied to evaluate the effect of each component. In the control groups, Caries Detector was not applied to the dentin surfaces. Finally, a resin composite was light-cured and the TBS measured. Fractured specimens and treated dentin surfaces were observed by SEM. Caries Detector did not reduce the tensile bond strength of any adhesive system (p>0.05) when rinsed thoroughly. On the other hand, when dentin surface was contaminated with Caries Detector, TBS decreased significantly with Clearfil SE Bond and Single Bond. As for the ingredients of Caries Detector, the effect of acid red on TBS was not significant, but that of propylene glycol was significant
Helicases are nucleic acid-unwinding enzymes that are involved in the maintenance of genome integrity. Several parts of the amino acid sequences of helicases are very similar, and these quite well-conserved amino acid sequences are termed “helicase motifs”. Previous studies by X-ray crystallography and single-molecule measurements have suggested a common underlying mechanism for their function. These studies indicate the role of the helicase motifs in unwinding nucleic acids. In contrast, the sequence and length of the C-terminal amino acids of helicases are highly variable. In this paper, I review past and recent studies that proposed helicase mechanisms and studies that investigated the roles of the C-terminal amino acids on helicase and dimerization activities, primarily on the non-hexermeric Escherichia coli (E. coli) UvrD helicase. Then, I center on my recent study of single-molecule direct visualization of a UvrD mutant lacking the C-terminal 40 amino acids (UvrDΔ40C) used in studies proposing the monomer helicase model. The study demonstrated that multiple UvrDΔ40C molecules jointly participated in DNA unwinding, presumably by forming an oligomer. Thus, the single-molecule observation addressed how the C-terminal amino acids affect the number of helicases bound to DNA, oligomerization, and unwinding activity, which can be applied to other helicases.