Demid Popravko

Mr. Demid Popravko


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
EZElena A. Zvereva
Elena A. Zvereva
NBNadezhda A. Byzova
Nadezhda A. Byzova
OHOlga Hendrickson
Olga Hendrickson
DPDemid Popravko
Demid Popravko
KBKsenia Belichenko
Ksenia Belichenko
Anatoly V. ZherdevAnatoly V. Zherdev
Anatoly V. Zherdev
An immunochromatographic detection of myoglobin (MG) as a specific marker of porcine muscle tissue has been developed. The method is based on the sandwich lateral flow immunoassay (LFIA) with gold nanoparticles (AuNPs) as a label. The developed test system determines MG with a detection limit of 5 ng mL−1 within 15 min. A specific determination of porcine MG and no cross-reactivity with MG from other tested mammals and bird species was demonstrated. The test system is able to detect pork additives, as low as 0.01% (w/w), in minced beef. A technique of MG extraction from muscle tissue has been proposed which allows for rapid and efficient MG extraction from meat samples (within 20 min). The developed test system can serve as an effective means of controlling the authenticity and quality of meat products.

3 December 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
KSKsenia Serebrennikova
Ksenia Serebrennikova
OHOlga Hendrickson
Olga Hendrickson
EZElena A. Zvereva
Elena A. Zvereva
DPDemid Popravko
Demid Popravko
Anatoly V. ZherdevAnatoly V. Zherdev
Anatoly V. Zherdev
Boris B. DzantievBoris B. Dzantiev
Boris B. Dzantiev
This study provides a comparative assessment of the various nanodispersed markers and related detection techniques used in the immunochromatographic detection of an antibiotic lincomycin (LIN). Improving the sensitivity of the competitive lateral flow immunoassay is important, given the increasing demands for the monitoring of chemical contaminants in food. Gold nanoparticles (AuNPs) and CdSe/ZnS quantum dots (QDs) were used for the development and comparison of three approaches for the lateral flow immunoassay (LFIA) of LIN, namely, colorimetric, fluorescence, and surface-enhanced Raman spectroscopy (SERS)-based LFIAs. It was demonstrated that, for colorimetric and fluorescence analysis, the detection limits were comparable at 0.4 and 0.2 ng/mL, respectively. A SERS-based method allowed achieving the gain of five orders of magnitude in the assay sensitivity (1.4 fg/mL) compared to conventional LFIAs. Therefore, an integration of a SERS reporter into the LFIA is a promising tool for extremely sensitive quantitative detection of target analytes. However, implementation of this time-consuming technique requires expensive equipment and skilled personnel. In contrast, conventional AuNP- and QD-based LFIAs can provide simple, rapid, and inexpensive point-of-care testing for practical use.

13 November 2020 in Foods
Verified
Journal Article
Open access
PDF file
EZElena A. Zvereva
Elena A. Zvereva
DPDemid Popravko
Demid Popravko
OHOlga Hendrickson
Olga Hendrickson
NVNatalia Vostrikova Vostrikova
Natalia Vostrikova Vostrikova
ICIrina Chernukha
Irina Chernukha
Anatoly V. ZherdevAnatoly V. Zherdev
Anatoly V. Zherdev
A lateral flow immunoassay for sensitive detection of skeletal troponin I (TnI) as a specific, thermostable marker of muscle tissue was developed. Due to the antibodies’ choice, the assay specifically detects mammalian TnI (in beef, pork, lamb, and horse) but does not detect bird TnI (in chicken or turkey), thus enabling differentiation of these types of raw meat materials. The assay is based on a sandwich format of the analysis using gold nanoparticles as labels. The time of the assay is 15 min, and the TnI detection limit is 25 ng/mL. A buffer solution is proposed for efficient extraction of TnI from muscle tissues and from finished meat products that have undergone technological processing (smoking–cooking–smoking, cooking and smoking). The possibility of detecting beef addition in minced chicken down to 1% was demonstrated.

11 November 2021 in Molecules
Verified
Journal Article
Open access
PDF file
AIAleksandr V. Ivanov
Aleksandr V. Ivanov
DPDemid Popravko
Demid Popravko
ISIrina V. Safenkova
Irina V. Safenkova
EZElena A. Zvereva
Elena A. Zvereva
Boris B. DzantievBoris B. Dzantiev
Boris B. Dzantiev
Anatoly V. ZherdevAnatoly V. Zherdev
Anatoly V. Zherdev
Verifying the authenticity of food products is essential due to the recent increase in counterfeit meat-containing food products. The existing methods of detection have a number of disadvantages. Therefore, simple, cheap, and sensitive methods for detecting various types of meat are required. In this study, we propose a rapid full-cycle technique to control the chicken or pig adulteration of meat products, including 3 min of crude DNA extraction, 20 min of recombinase polymerase amplification (RPA) at 39 °C, and 10 min of lateral flow assay (LFA) detection. The cytochrome B gene was used in the developed RPA-based test for chicken and pig identification. The selected primers provided specific RPA without DNA nuclease and an additional oligonucleotide probe. As a result, RPA–LFA, based on designed fluorescein- and biotin-labeled primers, detected up to 0.2 pg total DNA per μL, which provided up to 0.001% w/w identification of the target meat component in the composite meat. The RPA–LFA of the chicken and pig meat identification was successfully applied to processed meat products and to meat after heating. The results were confirmed by real-time PCR. Ultimately, the developed analysis is specific and enables the detection of pork and chicken impurities with high accuracy in raw and processed meat mixtures. The proposed rapid full-cycle technique could be adopted for the authentication of other meat products.

2 November 2020 in Proceedings
Verified
Conference Paper
Open access
PDF file
OHOlga Hendrickson
Olga Hendrickson
KSKsenia Serebrennikova
Ksenia Serebrennikova
EZElena A. Zvereva
Elena A. Zvereva
DPDemid Popravko
Demid Popravko
Anatoly V. ZherdevAnatoly V. Zherdev
Anatoly V. Zherdev
Boris B. DzantievBoris B. Dzantiev
Boris B. Dzantiev
Improving the sensitivity of the competitive lateral flow immunoassay (LFIA) is important, given the increasing demands for the monitoring of chemical contaminants in food. The choice of nanosized marker is an essential task for improving the LFIA sensitivity. In this study, a CdSe/ZnS quantum dot (QD)-based LFIA combined with a portable reader was developed for rapid and quantitative detection of an antibiotic lincomycin (LIN). The performance of the proposed fluorescence LFIA was compared to the conventional gold nanoparticle (AuNP)-based LFIA realized with the same immunoreagents. The visual cutoff values were 10 ng/mL for AuNP-based LFIA and 20 ng/mL for QD-based LFIA. Furthermore, the instrumental limits of detection have been shown to be comparable for both nanosized markers and amounted to 0.4 ng/mL for AuNPs and 0.2 ng/mL for QDs, respectively. According to the results obtained, both LFIAs may be used for rapid, cost-effective, on-site testing of antibiotics, in particular LIN. However, the QD-based LFIA exhibits lowest limit of detection with the least immunoreagent consumption, which makes it economically beneficial.