Ksenia Serebrennikova

Ms. Ksenia Serebrennikova


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
KSKsenia Serebrennikova
Ksenia Serebrennikova
ABAnna N. Berlina
Anna N. Berlina
Dmitriy SotnikovDmitriy Sotnikov
Dmitriy Sotnikov
Anatoly V. ZherdevAnatoly V. Zherdev
Anatoly V. Zherdev
Boris B. DzantievBoris B. Dzantiev
Boris B. Dzantiev
The growing interest in the development of new platforms for the application of Raman spectroscopy techniques in biosensor technologies is driven by the potential of these techniques in identifying chemical compounds, as well as structural and functional features of biomolecules. The effect of Raman scattering is a result of inelastic light scattering processes, which lead to the emission of scattered light with a different frequency associated with molecular vibrations of the identified molecule. Spontaneous Raman scattering is usually weak, resulting in complexities with the separation of weak inelastically scattered light and intense Rayleigh scattering. These limitations have led to the development of various techniques for enhancing Raman scattering, including resonance Raman spectroscopy (RRS) and nonlinear Raman spectroscopy (coherent anti-Stokes Raman spectroscopy and stimulated Raman spectroscopy). Furthermore, the discovery of the phenomenon of enhanced Raman scattering near metallic nanostructures gave impetus to the development of the surface-enhanced Raman spectroscopy (SERS) as well as its combination with resonance Raman spectroscopy and nonlinear Raman spectroscopic techniques. The combination of nonlinear and resonant optical effects with metal substrates or nanoparticles can be used to increase speed, spatial resolution, and signal amplification in Raman spectroscopy, making these techniques promising for the analysis and characterization of biological samples. This review provides the main provisions of the listed Raman techniques and the advantages and limitations present when applied to life sciences research. The recent advances in SERS and SERS-combined techniques are summarized, such as SERRS, SE-CARS, and SE-SRS for bioimaging and the biosensing of molecules, which form the basis for potential future applications of these techniques in biosensor technology. In addition, an overview is given of the main tools for success in the development of biosensors based on Raman spectroscopy techniques, which can be achieved by choosing one or a combination of the following approaches: (i) fabrication of a reproducible SERS substrate, (ii) synthesis of the SERS nanotag, and (iii) implementation of new platforms for on-site testing.

13 December 2017 in Nano-Micro Letters
Verified
Journal Article
Open access
PDF file
KSKsenia Serebrennikova
Ksenia Serebrennikova
JSJeanne Samsonova
Jeanne Samsonova
AOAlexander Osipov
Alexander Osipov
Lateral flow immunoassay (LFIA) is a widely used express method and offers advantages such as a short analysis time, simplicity of testing and result evaluation. However, an LFIA based on gold nanospheres lacks the desired sensitivity, thereby limiting its wide applications. In this study, spherical nanogold labels along with new types of nanogold labels such as gold nanopopcorns and nanostars were prepared, characterized, and applied for LFIA of model protein antigen procalcitonin. It was found that the label with a structure close to spherical provided more uniform distribution of specific antibodies on its surface, indicative of its suitability for this type of analysis. LFIA using gold nanopopcorns as a label allowed procalcitonin detection over a linear range of 0.5–10 ng mL−1 with the limit of detection of 0.1 ng mL−1, which was fivefold higher than the sensitivity of the assay with gold nanospheres. Another approach to improve the sensitivity of the assay included the silver enhancement method, which was used to compare the amplification of LFIA for procalcitonin detection. The sensitivity of procalcitonin determination by this method was 10 times better the sensitivity of the conventional LFIA with gold nanosphere as a label. The proposed approach of LFIA based on gold nanopopcorns improved the detection sensitivity without additional steps and prevented the increased consumption of specific reagents (antibodies). Open image in new window

10 December 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
KSKsenia Serebrennikova
Ksenia Serebrennikova
NBNadezhda A. Byzova
Nadezhda A. Byzova
Anatoly V. ZherdevAnatoly V. Zherdev
Anatoly V. Zherdev
BKBoris Khlebtsov
Boris Khlebtsov
BKBoris Khlebtsov
Boris Khlebtsov
Boris B. DzantievBoris B. Dzantiev
Boris B. Dzantiev
The current COVID-19 pandemic has increased the demand for pathogen detection methods that combine low detection limits with rapid results. Despite the significant progress in methods and devices for nucleic acid amplification, immunochemical methods are still preferred for mass testing without specialized laboratories and highly qualified personnel. The most widely used immunoassays are microplate enzyme-linked immunosorbent assay (ELISA) with photometric detection and lateral flow immunoassay (LFIA) with visual results assessment. However, the disadvantage of ELISA is its considerable duration, and that of LFIA is its low sensitivity. In this study, the modified LFIA of a specific antigen of the causative agent of COVID-19, spike receptor-binding domain, was developed and characterized. This modified LFIA includes the use of gold nanoparticles with immobilized antibodies and 4-mercaptobenzoic acid as surface-enhanced Raman scattering (SERS) nanotag and registration of the nanotag binding by SERS spectrometry. To enhance the sensitivity of LFIA-SERS analysis, we determined the optimal compositions of SERS nanotags and membranes used in LFIA. For benchmark comparison, ELISA and conventional colorimetric LFIA were used with the same immune reagents. The proposed method combines a low detection limit of 0.1 ng/mL (at 0.4 ng/mL for ELISA and 1 ng/mL for qualitative LFIA) with a short assay time equal to 20 min (at 3.5 h for ELISA and 15 min for LFIA). The results obtained demonstrate the promise of using the SERS effects in membrane immuno-analytical systems.

25 November 2021 in Chemosensors
Verified
Journal Article
Open access
PDF file
KSKsenia Serebrennikova
Ksenia Serebrennikova
NKNadezhda S. Komova
Nadezhda S. Komova
Anna N. BerlinaAnna N. Berlina
Anna N. Berlina
Anatoly V. ZherdevAnatoly V. Zherdev
Anatoly V. Zherdev
Boris B. DzantievBoris B. Dzantiev
Boris B. Dzantiev
In this study, tannic acid-modified gold nanoparticles were found to have superior nanozyme activity and catalyze the oxidation reaction of 3,3′,5,5′-tetramethylbenzidine in the presence of hydrogen peroxide. Enhancing the catalytic activity of the nanozyme by Pb2+ ions caused by selectively binding metal ions by the tannic acid-capped surface of gold nanoparticles makes them an ideal colorimetric probe for Pb2+. The parameters of the reaction, including pH, incubation time, and concentration of components, were optimized to reach maximal sensitivity of Pb2+ detection. The absorption change is directly proportional to the Pb2+ concentration and allows the determination of Pb2+ ions within 10 min. The colorimetric sensor is characterized by a wide linear range from 25 to 500 ng×mL−1 with a low limit of detection of 11.3 ng×mL−1. The highly sensitive and selective Pb2+ detection in tap, drinking, and spring water revealed the feasibility and applicability of the developed colorimetric sensor.

11 June 2019 in Microchimica Acta
Verified
Journal Article
Closed access
PDF file
KSKsenia Serebrennikova
Ksenia Serebrennikova
JSJeanne V. Samsonova
Jeanne V. Samsonova
AOAlexander P. Osipov
Alexander P. Osipov

3 December 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
KSKsenia Serebrennikova
Ksenia Serebrennikova
OHOlga Hendrickson
Olga Hendrickson
EZElena A. Zvereva
Elena A. Zvereva
DPDemid Popravko
Demid Popravko
Anatoly V. ZherdevAnatoly V. Zherdev
Anatoly V. Zherdev
Boris B. DzantievBoris B. Dzantiev
Boris B. Dzantiev
This study provides a comparative assessment of the various nanodispersed markers and related detection techniques used in the immunochromatographic detection of an antibiotic lincomycin (LIN). Improving the sensitivity of the competitive lateral flow immunoassay is important, given the increasing demands for the monitoring of chemical contaminants in food. Gold nanoparticles (AuNPs) and CdSe/ZnS quantum dots (QDs) were used for the development and comparison of three approaches for the lateral flow immunoassay (LFIA) of LIN, namely, colorimetric, fluorescence, and surface-enhanced Raman spectroscopy (SERS)-based LFIAs. It was demonstrated that, for colorimetric and fluorescence analysis, the detection limits were comparable at 0.4 and 0.2 ng/mL, respectively. A SERS-based method allowed achieving the gain of five orders of magnitude in the assay sensitivity (1.4 fg/mL) compared to conventional LFIAs. Therefore, an integration of a SERS reporter into the LFIA is a promising tool for extremely sensitive quantitative detection of target analytes. However, implementation of this time-consuming technique requires expensive equipment and skilled personnel. In contrast, conventional AuNP- and QD-based LFIAs can provide simple, rapid, and inexpensive point-of-care testing for practical use.