Martina Kutija

Prof. Dr. Martina Kutija

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 July 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MMMartin Makar
Martin Makar
LPLuka Pravica
Luka Pravica
MKMartina Kutija
Martina Kutija
Improving energy efficiency is the most important goal for buildings today. One of the ways to increase energy efficiency is to use the regenerative potential of elevators. Due to the special requirements of elevator drives, energy storage systems based on supercapacitors are the most suitable for storing regenerative energy. This paper proposes an energy storage system consisting of a supercapacitor bank and a bidirectional six-phase interleaved DC/DC converter. The energy savings achieved by the proposed system were investigated through simulation tests. The proposed system was modeled considering all physical constraints. A simulation model of the existing faculty elevator system was created in PLECS and verified with field measurements. Reliable results were ensured by using the verified simulation model and considering all physical constraints. The operation of the proposed energy storage system was tested under various conditions. In addition, the simulation model of the elevator system with the proposed energy storage system was tested using the elevator traffic data obtained from the measurements. The simulation results show the effectiveness of the proposed energy storage system and that significant energy savings can be achieved.

11 May 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MKMartina Kutija
Martina Kutija
LPLuka Pravica
Luka Pravica
This paper presents a case study of three-phase ferroresonance in a low-voltage power factor correction system and investigates the influence of harmonic distortion on the occurrence of ferroresonance. Ferroresonance is an extremely dangerous and rare phenomenon that causes overvoltages and overcurrents in the system and degrades the power quality. The study is carried out on real field measurements in an industrial plant where ferroresonance occurs in the power factor correction (PFC) system at the detuned reactor. The three-phase ferroresonance analysed in this paper is an extremely rare phenomenon that has never been reported in this type of configuration. The measurement results have shown that in this type of configuration the high harmonic distortion is a necessary condition for ferroresonance to occur. In such conditions, switching on the capacitor stage triggers the ferroresonance with quasi-periodic oscillations supported by the medium voltage grid. The main contribution is the analysis of the three-phase ferroresonance in the detuned PFC system and the influence of the harmonics on the occurrence of the ferroresonance in such a case. The possible solutions to this problem and recommendations to avoid this phenomenon are discussed.

1 February 2017 in Electric Power Systems Research
Verified
Journal Article
Closed access
IEIgor Erceg
Igor Erceg
DSDamir Sumina
Damir Sumina
STStjepan Tusun
Stjepan Tusun
MKMartina Kutija
Martina Kutija

25 September 2023
Verified
Conference Paper
Closed access
MMMartin Makar
Martin Makar
MKMartina Kutija
Martina Kutija
MKMarinko Kovacic
Marinko Kovacic
TITomislav Ivaniš
Tomislav Ivaniš
This paper analyses the conducted electromagnetic interference in a bidirectional non-isolated interleaved DC-DC converter operating in discontinuous conducted mode (DCM) and used in an elevator energy storage system. The analysis is performed by simulation testing using LTspice simulation software, where the simulation model of the DC-DC converter is built using the parameters of a laboratory prototype. The effects of operation in DCM on the conducted common mode noise (CM) and differential mode noise (DM) are investigated with the aim of tuning the EMI filter. In addition, the effect of snubbers on CM conducted currents is investigated. The analysis is performed for both buck and boost operation of the DC-DC converter at a maximum power of 4.5 kW.