Improving energy efficiency is the most important goal for buildings today. One of the ways to increase energy efficiency is to use the regenerative potential of elevators. Due to the special requirements of elevator drives, energy storage systems based on supercapacitors are the most suitable for storing regenerative energy. This paper proposes an energy storage system consisting of a supercapacitor bank and a bidirectional six-phase interleaved DC/DC converter. The energy savings achieved by the proposed system were investigated through simulation tests. The proposed system was modeled considering all physical constraints. A simulation model of the existing faculty elevator system was created in PLECS and verified with field measurements. Reliable results were ensured by using the verified simulation model and considering all physical constraints. The operation of the proposed energy storage system was tested under various conditions. In addition, the simulation model of the elevator system with the proposed energy storage system was tested using the elevator traffic data obtained from the measurements. The simulation results show the effectiveness of the proposed energy storage system and that significant energy savings can be achieved.
This paper analyses the conducted electromagnetic interference in a bidirectional non-isolated interleaved DC-DC converter operating in discontinuous conducted mode (DCM) and used in an elevator energy storage system. The analysis is performed by simulation testing using LTspice simulation software, where the simulation model of the DC-DC converter is built using the parameters of a laboratory prototype. The effects of operation in DCM on the conducted common mode noise (CM) and differential mode noise (DM) are investigated with the aim of tuning the EMI filter. In addition, the effect of snubbers on CM conducted currents is investigated. The analysis is performed for both buck and boost operation of the DC-DC converter at a maximum power of 4.5 kW.
The efficiency of the DC microgrid can be improved by adding additional energy storage to recover regenerative braking energy. Supercapacitors are well suited for such applications. To make such devices easily connectable to the existing grid, it is beneficial to measure the voltage of the DC bus. The paper proposes a method on how to estimate load current indirectly from this voltage measurement. Estimated current is used in the developed energy management algorithm that adapts current reference of an energy storage system to discharge stored energy in the most energy efficient way. The paper presents simulation and experimental results and shows in some cases efficiency improvement even by more than five percent.