Frédéric Skoczylas

Prof. Frédéric Skoczylas

Univ. Lille, CNRS, Centrale Lille, UMR9013 – LaMcube – Laboratoire de mécanique multiphysique et multiéchelle, F-59000, Lille, France

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2004 in International Journal of Rock Mechanics and Mining Sciences
Verified
Journal Article
Closed access
MLM Lion
M Lion
FSFrédéric Skoczylas
Frédéric Skoczylas
BLB Ledésert
B Ledésert

27 May 2020 in Rock Mechanics and Rock Engineering
Verified
Journal Article
Closed access
PDF file
DZDongmei Zhang
Dongmei Zhang
FSFrédéric Skoczylas
Frédéric Skoczylas
FAFranck Agostini
Franck Agostini
LJLaurent Jeannin
Laurent Jeannin

1 February 2017 in International Journal of Rock Mechanics and Mining Sciences
Verified
Journal Article
Closed access
HYHaifeng Yuan
Haifeng Yuan
FAFranck Agostini
Franck Agostini
ZDZhibo Duan
Zhibo Duan
FSFrédéric Skoczylas
Frédéric Skoczylas
JTJean Talandier
Jean Talandier

1 November 2018 in Journal of Natural Gas Science and Engineering
Verified
Journal Article
Closed access
YXYifan Xu
Yifan Xu
Yi WangYi Wang
Yi Wang
HYHaifeng Yuan
Haifeng Yuan
DZDongmei Zhang
Dongmei Zhang
FAFranck Agostini
Franck Agostini
FSFrédéric Skoczylas
Frédéric Skoczylas

29 November 2022 in Materials
Verified
Journal Article
Open access
PDF file
WCwei chen
wei chen
SDSong Dong
Song Dong
YLYuehan Liu
Yuehan Liu
YLYue Liang
Yue Liang
FSFrédéric Skoczylas
Frédéric Skoczylas
Currently, most cities landfill most waste glass, resulting in the waste of resources and environmental pollution. Therefore, to realize the recycling of waste glass, solid waste glass was recycled and broken. Waste glass sand was prepared according to the gradation of natural river sand particles and the fineness modulus screening. It was used as an alternative material to natural river sand and mixed with mortar materials with different replacements. Analysis of the mortar with different replacements (0%, 20%, 40%, 60%, 80%) was conducted by combining macro and micro tests on the change law and influence mechanism of permeability, mechanical properties, and microstructure. The results showed that: the replacement of waste glass sand effectively improved the gas permeation resistance of mortar; with the increase of replacement, the gas permeation resistance of mortar roughly showed a trend of increasing first and then decreasing. The replacement of waste glass sand at 20% can better promote cement’s hydration so that the mortar’s porosity is reduced by 16.5%. The gas permeability decreases by 57.4%; the compressive strength increases by 3%, and the elastic modulus increases by 5.9%. When the replacement rate of glass sand is 20%, the test performance of mortar is the best among the five groups.

11 February 2021 in Materials
Verified
Journal Article
Open access
PDF file
WCwei chen
wei chen
YHYixuan Han
Yixuan Han
FAFranck Agostini
Franck Agostini
FSFrédéric Skoczylas
Frédéric Skoczylas
DCDidier Corbeel
Didier Corbeel
The effects of confining pressure are investigated for two samples of a macro-cracked concrete. Samples are first macro-cracked with a splitting tensile strength test (Brazilian) technique. Gas permeability is continually measured under increasing (or decreasing) confining pressure, whereas crack closure (or opening) is recorded with an LVDT (Linear Variable Differential Transformer) device. Despite a mechanical closure of the macro-crack, identified at around 20 MPa confining pressure, gas permeability continues to decrease as confinement is increased. This means that a model of the macro-crack by two parallel planes (using Poiseuille law) cannot be used to represent permeability variations during closure (or opening) of cracks. As a consequence, a physical model is designed in order to simulate with a better consistency the real behaviour of the macro-crack. This simple modelling allows both behaviours, mechanical and hydraulic, under confining pressure, to be simulated with the same set of parameters.