Miće Jakić

Dr. Miće Jakić

Department of Organic Technology, Faculty of Chemistry and Technology, University of Split, Ruđer Bošković 35, 21000 Split, Croatia
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 October 2015 in Journal of Thermal Analysis and Calorimetry
Verified
Journal Article
Closed access
PDF file
Miće JakićMiće Jakić
Miće Jakić
NVNataša Stipanelov Vrandečić
Nataša Stipanelov Vrandečić
Matko ErcegMatko Erceg
Matko Erceg

19 August 2016 in Journal of Thermal Analysis and Calorimetry
Verified
Journal Article
Closed access
PDF file
Miće JakićMiće Jakić
Miće Jakić
NVNataša Stipanelov Vrandečić
Nataša Stipanelov Vrandečić
Matko ErcegMatko Erceg
Matko Erceg

25 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
APAndrea Paut
Andrea Paut
Ante PrkićAnte Prkić
Ante Prkić
Ivana MitarIvana Mitar
Ivana Mitar
PBPerica Bošković
Perica Bošković
Dražan JozićDražan Jozić
Dražan Jozić
TVTina Vukušić
Tina Vukušić
A novel ion-selective electrode with membranes based on iron(III) phosphate and silver sulfide integrated into a completely new electrode body design has been developed for the determination of iron(III) cations. The best response characteristics with linear potential change were found in the iron(III) concentration range from 3.97 × 10−5 to 10−2 mol L−1. The detection limit was found to be 2.41 × 10−5 mol L−1 with a slope of −20.53 ± 0.63 and regression coefficient of 0.9925, while the quantification limit was 3.97 × 10−5 M. The potential change per concentration decade ranged from −13.59 ± 0.54 to −20.53 ± 1.56 for Electrode Body 1 (EB1) and from −17.28 ± 1.04 to −24 ± 1.87 for Electrode Body 2 (EB2), which is presented for the first time in this work. The prepared electrode has a long lifetime and the ability to detect changes in the concentration of iron cations within 20 s. Membrane M1 showed high recoveries in the determination of iron cations in iron(III) standard solutions (98.2–101.2%) as well as in two different pharmaceuticals (98.6–106.5%). This proves that this type of sensor is applicable in the determination of ferric cations in unknown samples, and the fact that all sensor parts are completely manufactured in our laboratory proves the simplicity of the method.

23 July 2025 in Buildings
Verified
Journal Article
Open access
PDF file
DBDamir Barbir
Damir Barbir
PDPero Dabić
Pero Dabić
Miće JakićMiće Jakić
Miće Jakić
IWIvana Weber
Ivana Weber
This study investigates the effects of incorporating recycled concrete powder (RCP) as a supplementary cementitious material in Portland cement composites at replacement levels of 5–30% by weight. A comprehensive characterization using isothermal calorimetry, electrical conductivity measurements, thermogravimetric analysis, FT-IR spectroscopy, and scanning electron microscopy revealed that RCP modified the hydration behavior and microstructural development. The results showed a linear 16.5% reduction in the total heat of hydration (from 145.38 to 121.44 J/g) at 30% RCP content, accompanied by a 26.5% decrease in peak electrical conductivity (19.16 to 14.08 mS/cm) and delayed reaction kinetics. Thermal analysis demonstrated an increased stability of hydration products, with portlandite decomposition temperatures rising by up to 10.8 °C. Microstructural observations confirmed the formation of denser but more amorphous C–S–H phases alongside increased interfacial porosity at higher RCP contents. The study provides quantitative evidence of RCP’s dual functionality as both an inert filler and a nucleation agent, identifying an optimal 20–25% replacement range that balances performance and sustainability. These findings advance the understanding of construction waste utilization in cementitious materials and provide practical solutions for developing more sustainable building composites while addressing circular economy objectives in the construction sector.

16 May 2024 in Tehnički glasnik
Verified
Journal Article
Open access
PDF file
Miće JakićMiće Jakić
Miće Jakić
ASAna Santro
Ana Santro
EZEla Zečić
Ela Zečić
SJSanja Perinović Jozić
Sanja Perinović Jozić
Poly(vinyl alcohol) (PVA) and poly(ethylene) oxide (PEO) are widely used water-soluble and biodegradable polymers that possesses high biocompatibility. In this work PVA/PEO blends were prepared via solution casting method, where the solvent was water...

9 October 2020 in Journal of Thermal Analysis and Calorimetry
Verified
Journal Article
Closed access
PDF file
JJJelena Jakić
Jelena Jakić
Miće JakićMiće Jakić
Miće Jakić
MLMiroslav Labor
Miroslav Labor