The application of the Phasor Measurement Unit (PMU) in the power system is expanding day by day since it provides a higher reliability through fast symmetrically monitoring and protection and assists in controlling power systems. For power systems, islanding is a significant event due to its hazardous consequences. To detect islanding events, several schemes have been previously proposed but inappropriate threshold setting, higher computational time, and false tripping are the main limitations. In addition, differentiating between real island events and transient faults is another limitation. However, appropriate threshold setting plays a considerable part in detecting the island event, which is also important to differentiate between real and non-island events. Phasor Measurement Unit can assist in islanding detection, but it can generate 30 samples/s, so there is always the possibility of making particular period data disappear. The principal contribution of this review article is its detailed discussion of real-time symmetrical PMU data and it further presents different PMU data analytic techniques and the proposed schemes for the islanding detection system. An appropriate methodology tried to understand how to incorporate missing PMU data techniques along with the islanding detection system to ensure the higher reliability of the network.
Recent developments in electrical power systems are concerned not only with static power flow control but also with their control during dynamic processes. Smart Grids came into being when it was noticed that the traditional electrical power system structure was lacking in reliability, power flow control, and consistency in the monitoring of phasor quantities. The Phasor Measurement Unit (PMU) is one of the main critical factors for Smart Grid (SG) operation. It has the ability to provide real-time synchronized measurement of phasor quantities with the help of a Global Positioning System (GPS). However, when considering the installation costs of a PMU device, it is far too expensive to equip on every busbar in all grid stations. Therefore, this paper proposes a new approach for the Optimum Placement of the PMU problem (OPP problem) to minimize the installed number of PMUs and maximize the measurement redundancy of the network. Exclusion of the unwanted nodes technique is used in the proposed approach, in which only the most desirable buses consisting of generator bus and load bus are selected, without considering Pure Transit Nodes (PTNs) in the optimum PMU placement sets. The focal point of the proposed work considers, most importantly, the case factor of the exclusion technique of PTNs from the optimum PMU locations, as prior approaches concerning almost every algorithm have taken PTNs as their optimal PMU placement sets. Furthermore, other case factors of the proposed approach, namely, PMU channel limits, radial bus, and single PMU outage, are also considered for the OPP problem. The proposed work is tested on standard Institute of Electrical and Electronics Engineering (IEEE)-case studies from MATPOWER on the MATLAB software. To show the success of the proposed work, the outputs are compared with the existing techniques.