Weiguang Ma

Dr. Weiguang Ma


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2020 in Optics Letters
Verified
Journal Article
Closed access
HCHong Chang
Hong Chang
SFShiling Feng
Shiling Feng
XQXuanbing Qiu
Xuanbing Qiu
HMHuiyan Meng
Huiyan Meng
GGGuqing Guo
Guqing Guo
CLChuanliang Li
Chuanliang Li
We developed a type of toroidal multi-pass cell with multi-layer patterns based on the off-axis model. The effective path length of the original toroidal multi-pass cell is extended several roundtrips in comparison with the single-layer pattern, since the inner surface of the toroidal multi-pass cell is more efficiently utilized. The light pattern has been achieved by using the simple ring surface, which is easy to fabricate. The exact analytical equations for the design of the toroidal multi-pass cell were derived based on analytical vector calculations. A series of numerical ray tracing simulations is presented, and the maximum theoretical optical path length that can be reached is 30 m with a setup of 5 cm column radius. Furthermore, two practical spot patterns are demonstrated with a path length of 8.3 m for a two-layer pattern and 10 m for a three-layer pattern, with respective effective volumes of 63 mL and 94 mL. Furthermore, the fringe effect is substantially reduced to less than 0.5% by the usage of our designed mask.

14 April 2023 in Optics Letters
Verified
Journal Article
Closed access
HGHu Ge
Hu Ge
WKWeiping Kong
Weiping Kong
RWRui Wang
Rui Wang
GZGang Zhao
Gang Zhao
WMWeiguang Ma
Weiguang Ma
FWFu Wan
Fu Wan
We report a novel, to the best of our knowledge, and simple technique to lock a 642 nm multi-quantum well diode laser to an external linear power buildup cavity by directly feeding the cavity reflected light back to the diode laser for enhancement of gas Raman signals. The dominance of the resonant light field in the locking process is achieved by reducing the reflectivity of the cavity input mirror and thus making the intensity of the directly reflected light weaker than that of the resonant light. Compared with traditional techniques, stable power buildup in the fundamental transverse mode TEM00 is guaranteed without any additional optical elements or complex optical arrangements. An intracavity exciting light of 160 W is generated with a 40 mW diode laser. Using a backward Raman light collection geometry, detection limits at the ppm level are achieved for ambient gases (N2, O2) with an exposure time of 60 s.

19 March 2024 in Optics Express
Verified
Journal Article
Closed access
FWFu Wan
Fu Wan
RWRui Wang
Rui Wang
HGHu Ge
Hu Ge
WKWeiping Kong
Weiping Kong
HSHongcheng Sun
Hongcheng Sun
WCWeigen Chen
Weigen Chen
The challenges presented by the directly reflected field in optical feedback cavity-enhanced spectroscopy systems serve as substantial obstacles, introducing additional complexity to existing systems and compromising their sensitivity, as the underlying mechanisms of its adverse effects remain not fully understood. This study aims to address this issue by introducing a comprehensive analytical model. Additionally, frequency locking can be achieved by decreasing the feedback rate, the laser’s linewidth enhancement factor, and the directly reflected field, and by increasing the refractive index of the gain medium, the length of the laser’s resonant cavity, the electric field reflectivity of the laser’s output facet, and the resonant field. These parameters can affect the feedback coupling rate pre-factor, and for a resonant cavity with a length of 0.394 m, optical feedback can only be established when the feedback coupling rate pre-factor is less than 1.05 × 109. Through experimental validation, we successfully confirm the effectiveness of the proposed solution in eliminating the detrimental effects of the directly reflected field. Importantly, this suppression is achieved without compromising other aspects of the system's performance. The research findings not only offer the potential to optimize various cavity-enhanced spectroscopy systems that rely on optical feedback but also show promising applications in advancing the development of high-purity spectrum diode lasers utilizing optical feedback from an external high-finesse cavity.

25 October 2018 in Optics Express
Verified
Journal Article
Closed access
PDF file
CLChuanliang Li
Chuanliang Li
LSLigang Shao
Ligang Shao
HMHuiyan Meng
Huiyan Meng
JWJilin Wei
Jilin Wei
XQXuanbing Qiu
Xuanbing Qiu
YCYangqin Chen
Yangqin Chen
We report a multi-pass tunable diode laser absorption spectrometer based on the frequency-modulation spectroscopy (FMS) technique. It has the advantage of high scan speed and is immune to the etalon effect. A multi-pass Herriott-type cell was used in the spectrometer to increase the effective optical length to 17.5 m and compact the physical dimensions of the spectrometer to 60×30×30 cm3. Noise due to low-frequency fluctuation of the laser power and the 1/f noise in the rapid detection are sufficiently reduced by FMS. Interference fringes are effectively suppressed when the modulation frequency equals to integer or half-integer times of their free spectral range (FSR). An absorption line of C2H2 around 1.51 µm was recorded with the spectrometer to demonstrate its capabilities. The response frequency of the spectrometer is up to 100 kHz (10 µs) thanks to the high modulation frequency of FMS. The detection sensitivity of the spectrometer is about 240 ppb (3σ) at 100 kHz measurement repetition rate. The amplitude of the absorption signal is highly linear to the C2H2 concentration in the range of 300 ppb -100 ppm. Based on the Allan variation, the detection limit was determined to be 18 ppb with a detection time of 166 s.

27 January 2016 in Sensors
Verified
Journal Article
Open access
PDF file
Xukun YinXukun Yin
Xukun Yin
Lei DongLei Dong
Lei Dong
HZHuadan Zheng
Huadan Zheng
XLXiaoli Liu
Xiaoli Liu
HWHongpeng Wu
Hongpeng Wu
SJSuotang Jia
Suotang Jia
A near-IR CO trace gas sensor based on quartz-enhanced photoacoustic spectroscopy (QEPAS) is evaluated using humidified nitrogen samples. Relaxation processes in the CO-N2-H2O system are investigated. A simple kinetic model is used to predict the sensor performance at different gas pressures. The results show that CO has a ~3 and ~5 times slower relaxation time constant than CH4 and HCN, respectively, under dry conditions. However, with the presence of water, its relaxation time constant can be improved by three orders of magnitude. The experimentally determined normalized detection sensitivity for CO in humid gas is 1.556 × 10 − 8 W ⋅ cm − 1 / Hz 1 / 2 .

21 October 2015 in Sensors
Verified
Journal Article
Open access
PDF file
HWHongpeng Wu
Hongpeng Wu
Lei DongLei Dong
Lei Dong
XLXiaoli Liu
Xiaoli Liu
HZHuadan Zheng
Huadan Zheng
Xukun YinXukun Yin
Xukun Yin
SJSuotang Jia
Suotang Jia
A selective and sensitive quartz enhanced photoacoustic spectroscopy (QEPAS) sensor, employing an erbium-doped fiber amplifier (EDFA), and a distributed feedback (DFB) laser operating at 1582 nm was demonstrated for simultaneous detection of ammonia (NH3) and hydrogen sulfide (H2S). Two interference-free absorption lines located at 6322.45 cm−1 and 6328.88 cm−1 for NH3 and H2S detection, respectively, were identified. The sensor was optimized in terms of current modulation depth for both of the two target gases. An electrical modulation cancellation unit was equipped to suppress the background noise caused by the stray light. An Allan-Werle variance analysis was performed to investigate the long-term performance of the fiber-amplifier-enhanced QEPAS sensor. Benefitting from the high power boosted by the EDFA, a detection sensitivity (1σ) of 52 parts per billion by volume (ppbv) and 17 ppbv for NH3 and H2S, respectively, were achieved with a 132 s data acquisition time at atmospheric pressure and room temperature.