Jerome Gateau

Dr. Jerome Gateau

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 March 2011 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JGJerome Gateau
Jerome Gateau
JAJF Aubry
JF Aubry
MPMathieu Pernot
Mathieu Pernot
MFMathias Fink
Mathias Fink
MTMickael Tanter
Mickael Tanter
The activation of natural gas nuclei to induce larger bubbles is possible using short ultrasonic excitations of high amplitude, and is required for ultrasound cavitation therapies. However, little is known about the distribution of nuclei in tissues. Therefore, the acoustic pressure level necessary to generate bubbles in a targeted zone and their exact location are currently difficult to predict. To monitor the initiation of cavitation activity, a novel all-ultrasound technique sensitive to single nucleation events is presented here. It is based on combined passive detection and ultrafast active imaging over a large volume using the same multi-element probe. Bubble nucleation was induced using a focused transducer (660 kHz, f-number = 1) driven by a high-power electric burst (up to 300 W) of one to two cycles. Detection was performed with a linear array (4 to 7 MHz) aligned with the single-element focal point. In vitro experiments in gelatin gel and muscular tissue are presented. The synchronized passive detection enabled radio-frequency data to be recorded, comprising high-frequency coherent wave fronts as signatures of the acoustic emissions linked to the activation of the nuclei. Active change detection images were obtained by subtracting echoes collected in the unnucleated medium. These indicated the appearance of stable cavitating regions. Because of the ultrafast frame rate, active detection occurred as quickly as 330 μs after the high-amplitude excitation and the dynamics of the induced regions were studied individually.

9 July 2013 in Optics Letters
Verified
Journal Article
Closed access
PDF file
MOMurad Omar
Murad Omar
JGJerome Gateau
Jerome Gateau
VNVasilis Ntziachristos
Vasilis Ntziachristos
We developed a raster-scan acoustic resolution broadband optoacoustic mesoscopy system and investigated the imaging performance using ultrasonic frequencies up to 125 MHz. The developed system achieves 7 μm axial resolution and transverse resolution of 30 μm reaching depths of at least 5 mm. This unprecedented performance is achieved by operating at out-of-focus ultrasonic detection and tomographic reconstruction. We demonstrate the limits reached due to the width of the laser pulse employed and showcase the technique on drosophila fly and drosophila pupae ex vivo.

26 December 2012 in Medical Physics
Verified
Journal Article
Closed access
JGJerome Gateau
Jerome Gateau
MCMiguel Ángel Araque Caballero
Miguel Ángel Araque Caballero
ADAlexander Dima
Alexander Dima
VNVasilis Ntziachristos
Vasilis Ntziachristos

27 November 2013 in Optics Letters
Verified
Journal Article
Closed access
PDF file
JGJerome Gateau
Jerome Gateau
TCThomas Chaigne
Thomas Chaigne
OKOri Katz
Ori Katz
SGSylvain Gigan
Sylvain Gigan
EBEmmanuel Bossy
Emmanuel Bossy
In high-frequency photoacoustic imaging with uniform illumination, homogeneous photoabsorbing structures may be invisible because of their large size or limited-view issues. Here we show that, by exploiting dynamic speckle illumination, it is possible to reveal features that are normally invisible with a photoacoustic system comprised of a 20 MHz linear ultrasound array. We demonstrate imaging of a ∅5  mm absorbing cylinder and a 30 μm black thread arranged in a complex shape. The hidden structures are directly retrieved from photoacoustic images recorded for different random speckle illuminations of the phantoms by assessing the variation in the value of each pixel over the illumination patterns.

25 June 2014 in Optics Letters
Verified
Journal Article
Closed access
PDF file
MOMurad Omar
Murad Omar
DSDominik Soliman
Dominik Soliman
JGJerome Gateau
Jerome Gateau
VNVasilis Ntziachristos
Vasilis Ntziachristos
We developed a reflection-mode optoacoustic mesoscopy system, based on raster-scanning of a custom designed spherically focused ultrasound detector, enabling seamless epi-illumination of the volume imaged. We study the performance of acoustic-resolution mesoscopy operating at an ultrawideband bandwidth of 20–180 MHz. i.e., a frequency band spreading over virtually an order of magnitude. Using tomographic reconstruction we showcase previously unreported, to our knowledge, axial resolutions of 4 μm and transverse resolutions of 18 μm reaching depths of up to 5 mm. We further investigate the frequency-dependence of features seen on the images to understand the implications of ultrawideband measurements. We show the overall imaging performance and the frequency ranges that contribute to observable resolution improvements from phantoms and animals.

12 January 2016 in Optica
Verified
Journal Article
Open access
PDF file
TCThomas Chaigne
Thomas Chaigne
JGJerome Gateau
Jerome Gateau
MAMarc Allain
Marc Allain
OKOri Katz
Ori Katz
SGSylvain Gigan
Sylvain Gigan
EBEmmanuel Bossy
Emmanuel Bossy
In deep tissue photoacoustic imaging, the spatial resolution is inherently limited by acoustic diffraction. Moreover, as the ultrasound attenuation increases with frequency, resolution is often traded off for penetration depth. Here, we report on super-resolution photoacoustic imaging by use of multiple speckle illumination. Specifically, we demonstrate experimentally that the analysis of second-order fluctuations of the photoacoustic images enables the resolution of optically absorbing structures beyond the acoustic diffraction limit, with a resolution enhancement of about 1.4. In addition, deconvolution was implemented to fully exploit the highest spatial frequencies available and resulted in an effective resolution enhancement of at least 1.6 in the lateral direction. Our method introduces a new framework that could potentially lead to deep tissue photoacoustic imaging with subacoustic resolution.