Luigi Della Torre

Mr. Luigi Della Torre


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
AMAlessandro Manoni
Alessandro Manoni
FLFederico Loreti
Federico Loreti
VRValeria Radicioni
Valeria Radicioni
DPDaniela Pellegrino
Daniela Pellegrino
LTLuigi Della Torre
Luigi Della Torre
Fernanda IrreraFernanda Irrera
Fernanda Irrera
We propose an unobtrusive, wearable, and wireless system for the pre-screening and follow-up in the domestic environment of specific sleep-related breathing disorders. This group of diseases manifests with episodes of apnea and hypopnea of central or obstructive origin, and it can be disabling, with several drawbacks that interfere in the daily patient life. The gold standard for their diagnosis and grading is polysomnography, which is a time-consuming, scarcely available test with many wired electrodes disseminated on the body, requiring hospitalization and long waiting times. It is limited by the night-by-night variability of sleep disorders, while inevitably causing sleep alteration and fragmentation itself. For these reasons, only a small percentage of patients achieve a definitive diagnosis and are followed-up. Our device integrates photoplethysmography, an accelerometer, a microcontroller, and a bluetooth transmission unit. It acquires data during the whole night and transmits to a PC for off-line processing. It is positioned on the nasal septum and detects apnea episodes using the modulation of the photoplethysmography signal during the breath. In those time intervals where the photoplethysmography is detecting an apnea, the accelerometer discriminates obstructive from central type thanks to its excellent sensitivity to thoraco-abdominal movements. Tests were performed on a hospitalized patient wearing our integrated system and the type III home sleep apnea testing recommended by The American Academy of Sleep Medicine. Results are encouraging: sensitivity and precision around 90% were achieved in detecting more than 500 apnea episodes. Least thoraco-abdominal movements and body position were successfully classified in lying down control subjects, paving the way toward apnea type classification.

14 September 2022 in Electronics
Verified
Journal Article
Open access
PDF file
BCBenedetta Caterina Casadei
Benedetta Caterina Casadei
AGAlessandro Gumiero
Alessandro Gumiero
GTGiorgio Tantillo
Giorgio Tantillo
LTLuigi Della Torre
Luigi Della Torre
Gabriella OlmoGabriella Olmo
Gabriella Olmo
High blood pressure is one of the most important precursors for Cardiovascular Diseases (CVDs), the most common cause of death in 2020, as reported by the World Health Organization (WHO). Moreover, many patients affected by neurodegenerative diseases (e.g., Parkinson’s Disease) exhibit impaired autonomic control, with inversion of the normal circadian arterial pressure cycle, and consequent augmented cardiovascular and fall risk. For all these reasons, a continuous pressure monitoring of these patients could represent a significant prognostic factor, and help adjusting their therapy. However, the existing cuff-based methods cannot provide continuous blood pressure readings. Our work is inspired by the newest approaches based on the photoplethysmographic (PPG) signal only, which has been used to continuously estimate systolic blood pressure (SP), using artificial neural networks (ANN), in order to create more compact and wearable devices. Our first database was derived from the PhysioNet resource; we extracted PPG and arterial blood pressure (ABP) signals, collected at a sampling frequency of 125 Hz, in a hospital environment. It consists of 249,672 PPG periods and the relative SP values. The second database was collected at STMicroelectronics s.r.l., in Agrate Brianza, using the MORFEA3 wearable device and a digital cuff-based sphygmomanometer, as reference. The pre-processing phase, in order to remove noise and motion artifacts and to segment the signal into periods, was carried out on Matlab R2019b. The noise removal was one of the challenging parts of the study because of the inaccuracy of the PPG signal during everyday-life activity, and this is the reason why the MORFEA3 dataset was acquired in a controlled environment in a static position. Different solutions were implemented to choose the input features that best represent the period morphology. The first database was used to train the multilayer feed-forward neural network with a back-propagation model, whereas the second one was used to test it. The results obtained in this project are promising and match the Association for the Advancement of Medical Instruments (AAMI) and the British Hypertension Society (BHS) standards. They show a Mean Absolute Error of 3.85 mmHg with a Standard Deviation of 4.29 mmHg, under the AAMI standard, and reach the grade A under the BHS standard.

27 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AMAlessandro Manoni
Alessandro Manoni
AGAlessandro Gumiero
Alessandro Gumiero
Alessandro ZampognaAlessandro Zampogna
Alessandro Zampogna
CCChiara Ciarlo
Chiara Ciarlo
LPLorenzo Panetta
Lorenzo Panetta
Fernanda IrreraFernanda Irrera
Fernanda Irrera
In this work, we propose a wireless wearable system for the acquisition of multiple biopotentials through charge transfer electrostatic sensors realized in MEMS technology. The system is designed for low power consumption and low invasiveness, and thus candidates for long-time monitoring in free-living conditions, with data recording on an SD or wireless transmission to an external elaborator. Thanks to the wide horizon of applications, research is very active in this field, and in the last few years, some devices have been introduced on the market. The main problem with those devices is that their operation is time-limited, so they do not match the growing demand for long monitoring, which is a must-have feature in diagnosing specific diseases. Furthermore, their versatility is hampered by the fact that they have been designed to record just one type of signal. Using ST-Qvar sensors, we acquired an electrocardiogram trace and single-channel scalp electroencephalogram from the frontal lobes, together with an electrooculogram. Excellent results from all three types of acquisition tests were obtained. The power consumption is very low, demonstrating that, thanks to the MEMS technology, a continuous acquisition is feasible for several days.

28 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Fernanda IrreraFernanda Irrera
Fernanda Irrera
AGAlessandro Gumiero
Alessandro Gumiero
Alessandro ZampognaAlessandro Zampogna
Alessandro Zampogna
FBFederico Boscari
Federico Boscari
AAAngelo Avogaro
Angelo Avogaro
Antonio SuppaAntonio Suppa
Antonio Suppa
We propose a new methodology for long-term biopotential recording based on an MEMS multisensor integrated platform featuring a commercial electrostatic charge-transfer sensor. This family of sensors was originally intended for presence tracking in the automotive industry, so the existing setup was engineered for the acquisition of electrocardiograms, electroencephalograms, electrooculograms, and electromyography, designing a dedicated front-end and writing proper firmware for the specific application. Systematic tests on controls and nocturnal acquisitions from patients in a domestic environment will be discussed in detail. The excellent results indicate that this technology can provide a low-power, unexplored solution to biopotential acquisition. The technological breakthrough is in that it enables adding this type of functionality to existing MEMS boards at near-zero additional power consumption. For these reasons, it opens up additional possibilities for wearable sensors and strengthens the role of MEMS technology in medical wearables for the long-term synchronous acquisition of a wide range of signals.

5 February 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
Fernanda IrreraFernanda Irrera
Fernanda Irrera
AGAlessandro Gumiero
Alessandro Gumiero
Alessandro ZampognaAlessandro Zampogna
Alessandro Zampogna
FBFederico Boscari
Federico Boscari
AAAngelo Avogaro
Angelo Avogaro
Antonio SuppaAntonio Suppa
Antonio Suppa
We propose a new methodology for long-time biopotential recording based on MEMS multisensor integrated platform featuring a commercial electrostatic charge transfer sensor. That family of sensors was originally intended for presence tracking in automotive, so the existing setup has been engineered for the acquisition of electrocardiogram, electroencephalogram, electrooculogram and electromyography, designing a dedicated front-end and writing a proper firmware for the specific application. Systematic tests on controls and nocturnal acquisitions from patients in domestic environment will be discussed in detail. The excellent results candidate this technology to provide a low power, unexplored solution to biopotentials acquisition. The technology breakthrough is in that it enables adding this type of functionality to existing MEMS boards at near-zero additional power consumption. For these reasons, they open to additional possibilities for wearable sensing and strengthen the role of MEMS technology in medical wearable applications for long time synchronous acquisition of a wide range of signals.