Alessandro Gumiero

Dr. Alessandro Gumiero


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
AMAlessandro Manoni
Alessandro Manoni
FLFederico Loreti
Federico Loreti
VRValeria Radicioni
Valeria Radicioni
DPDaniela Pellegrino
Daniela Pellegrino
LTLuigi Della Torre
Luigi Della Torre
Fernanda IrreraFernanda Irrera
Fernanda Irrera
We propose an unobtrusive, wearable, and wireless system for the pre-screening and follow-up in the domestic environment of specific sleep-related breathing disorders. This group of diseases manifests with episodes of apnea and hypopnea of central or obstructive origin, and it can be disabling, with several drawbacks that interfere in the daily patient life. The gold standard for their diagnosis and grading is polysomnography, which is a time-consuming, scarcely available test with many wired electrodes disseminated on the body, requiring hospitalization and long waiting times. It is limited by the night-by-night variability of sleep disorders, while inevitably causing sleep alteration and fragmentation itself. For these reasons, only a small percentage of patients achieve a definitive diagnosis and are followed-up. Our device integrates photoplethysmography, an accelerometer, a microcontroller, and a bluetooth transmission unit. It acquires data during the whole night and transmits to a PC for off-line processing. It is positioned on the nasal septum and detects apnea episodes using the modulation of the photoplethysmography signal during the breath. In those time intervals where the photoplethysmography is detecting an apnea, the accelerometer discriminates obstructive from central type thanks to its excellent sensitivity to thoraco-abdominal movements. Tests were performed on a hospitalized patient wearing our integrated system and the type III home sleep apnea testing recommended by The American Academy of Sleep Medicine. Results are encouraging: sensitivity and precision around 90% were achieved in detecting more than 500 apnea episodes. Least thoraco-abdominal movements and body position were successfully classified in lying down control subjects, paving the way toward apnea type classification.

23 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
IMIvan Mazzetta
Ivan Mazzetta
Alessandro ZampognaAlessandro Zampogna
Alessandro Zampogna
Antonio SuppaAntonio Suppa
Antonio Suppa
AGAlessandro Gumiero
Alessandro Gumiero
MPMarco Pessione
Marco Pessione
Fernanda IrreraFernanda Irrera
Fernanda Irrera
We propose a wearable sensor system for automatic, continuous and ubiquitous analysis of Freezing of Gait (FOG), in patients affected by Parkinson’s disease. FOG is an unpredictable gait disorder with different clinical manifestations, as the trembling and the shuffling-like phenotypes, whose underlying pathophysiology is not fully understood yet. Typical trembling-like subtype features are lack of postural adaptation and abrupt trunk inclination, which in general can increase the fall probability. The targets of this work are detecting the FOG episodes, distinguishing the phenotype and analyzing the muscle activity during and outside FOG, toward a deeper insight in the disorder pathophysiology and the assessment of the fall risk associated to the FOG subtype. To this aim, gyroscopes and surface electromyography integrated in wearable devices sense simultaneously movements and action potentials of antagonist leg muscles. Dedicated algorithms allow the timely detection of the FOG episode and, for the first time, the automatic distinction of the FOG phenotypes, which can enable associating a fall risk to the subtype. Thanks to the possibility of detecting muscles contractions and stretching exactly during FOG, a deeper insight into the pathophysiological underpinnings of the different phenotypes can be achieved, which is an innovative approach with respect to the state of art.

14 September 2022 in Electronics
Verified
Journal Article
Open access
PDF file
BCBenedetta Caterina Casadei
Benedetta Caterina Casadei
AGAlessandro Gumiero
Alessandro Gumiero
GTGiorgio Tantillo
Giorgio Tantillo
LTLuigi Della Torre
Luigi Della Torre
Gabriella OlmoGabriella Olmo
Gabriella Olmo
High blood pressure is one of the most important precursors for Cardiovascular Diseases (CVDs), the most common cause of death in 2020, as reported by the World Health Organization (WHO). Moreover, many patients affected by neurodegenerative diseases (e.g., Parkinson’s Disease) exhibit impaired autonomic control, with inversion of the normal circadian arterial pressure cycle, and consequent augmented cardiovascular and fall risk. For all these reasons, a continuous pressure monitoring of these patients could represent a significant prognostic factor, and help adjusting their therapy. However, the existing cuff-based methods cannot provide continuous blood pressure readings. Our work is inspired by the newest approaches based on the photoplethysmographic (PPG) signal only, which has been used to continuously estimate systolic blood pressure (SP), using artificial neural networks (ANN), in order to create more compact and wearable devices. Our first database was derived from the PhysioNet resource; we extracted PPG and arterial blood pressure (ABP) signals, collected at a sampling frequency of 125 Hz, in a hospital environment. It consists of 249,672 PPG periods and the relative SP values. The second database was collected at STMicroelectronics s.r.l., in Agrate Brianza, using the MORFEA3 wearable device and a digital cuff-based sphygmomanometer, as reference. The pre-processing phase, in order to remove noise and motion artifacts and to segment the signal into periods, was carried out on Matlab R2019b. The noise removal was one of the challenging parts of the study because of the inaccuracy of the PPG signal during everyday-life activity, and this is the reason why the MORFEA3 dataset was acquired in a controlled environment in a static position. Different solutions were implemented to choose the input features that best represent the period morphology. The first database was used to train the multilayer feed-forward neural network with a back-propagation model, whereas the second one was used to test it. The results obtained in this project are promising and match the Association for the Advancement of Medical Instruments (AAMI) and the British Hypertension Society (BHS) standards. They show a Mean Absolute Error of 3.85 mmHg with a Standard Deviation of 4.29 mmHg, under the AAMI standard, and reach the grade A under the BHS standard.

27 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AMAlessandro Manoni
Alessandro Manoni
AGAlessandro Gumiero
Alessandro Gumiero
Alessandro ZampognaAlessandro Zampogna
Alessandro Zampogna
CCChiara Ciarlo
Chiara Ciarlo
LPLorenzo Panetta
Lorenzo Panetta
Fernanda IrreraFernanda Irrera
Fernanda Irrera
In this work, we propose a wireless wearable system for the acquisition of multiple biopotentials through charge transfer electrostatic sensors realized in MEMS technology. The system is designed for low power consumption and low invasiveness, and thus candidates for long-time monitoring in free-living conditions, with data recording on an SD or wireless transmission to an external elaborator. Thanks to the wide horizon of applications, research is very active in this field, and in the last few years, some devices have been introduced on the market. The main problem with those devices is that their operation is time-limited, so they do not match the growing demand for long monitoring, which is a must-have feature in diagnosing specific diseases. Furthermore, their versatility is hampered by the fact that they have been designed to record just one type of signal. Using ST-Qvar sensors, we acquired an electrocardiogram trace and single-channel scalp electroencephalogram from the frontal lobes, together with an electrooculogram. Excellent results from all three types of acquisition tests were obtained. The power consumption is very low, demonstrating that, thanks to the MEMS technology, a continuous acquisition is feasible for several days.

28 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Fernanda IrreraFernanda Irrera
Fernanda Irrera
AGAlessandro Gumiero
Alessandro Gumiero
Alessandro ZampognaAlessandro Zampogna
Alessandro Zampogna
FBFederico Boscari
Federico Boscari
AAAngelo Avogaro
Angelo Avogaro
Antonio SuppaAntonio Suppa
Antonio Suppa
We propose a new methodology for long-term biopotential recording based on an MEMS multisensor integrated platform featuring a commercial electrostatic charge-transfer sensor. This family of sensors was originally intended for presence tracking in the automotive industry, so the existing setup was engineered for the acquisition of electrocardiograms, electroencephalograms, electrooculograms, and electromyography, designing a dedicated front-end and writing proper firmware for the specific application. Systematic tests on controls and nocturnal acquisitions from patients in a domestic environment will be discussed in detail. The excellent results indicate that this technology can provide a low-power, unexplored solution to biopotential acquisition. The technological breakthrough is in that it enables adding this type of functionality to existing MEMS boards at near-zero additional power consumption. For these reasons, it opens up additional possibilities for wearable sensors and strengthens the role of MEMS technology in medical wearables for the long-term synchronous acquisition of a wide range of signals.

29 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
NVNina Verdel
Nina Verdel
MDMiha Drobnič
Miha Drobnič
JMJan Maslik
Jan Maslik
KRKlara Björnander Rahimi
Klara Björnander Rahimi
GTGiorgio Tantillo
Giorgio Tantillo
Matej SupejMatej Supej
Matej Supej
A novel wearable smart patch can monitor various aspects of physical activity, including the dynamics of running, but like any new device developed for such applications, it must first be tested for validity. Here, we compare the step rate while running in place as measured by this smart patch to the corresponding values obtained utilizing ‘‘gold standard’’ MEMS accelerometers in combination with bilateral force plates equipped with HBM load cells, as well as the values provided by a three-dimensional motion capture system and the Garmin Dynamics Running Pod. The 15 healthy, physically active volunteers (age = 23 ± 3 years; body mass = 74 ± 17 kg, height = 176 ± 10 cm) completed three consecutive 20-s bouts of running in place, starting at low, followed by medium, and finally at high intensity, all self-chosen. Our major findings are that the rates of running in place provided by all four systems were valid, with the notable exception of the fast step rate as measured by the Garmin Running Pod. The lowest mean bias and LoA for these measurements at all rates were associated consistently with the smart patch.