A biosensor for measuring the antidiabetic potential of medicinal plants was developed by covalent immobilization of α-glucosidase (AG) enzyme onto amine-functionalized multi-walled carbon nanotubes (MWCNTs-NH2). The immobilized enzyme was entrapped in freeze-thawed polyvinyl alcohol (PVA) together with p-nitrophenyl-α-d-glucopyranoside (PNPG) on the screen-printed carbon electrode at low pH to prevent the premature reaction between PNPG and AG enzyme. The enzymatic reaction within the biosensor is inhibited by bioactive compounds in the medicinal plant extracts. The capability of medicinal plants to inhibit the AG enzyme on the electrode correlates to the potential of the medicinal plants to inhibit the production of glucose from the carbohydrate in the human body. Thus, the inhibition indicates the antidiabetic potential of the medicinal plants. The performance of the biosensor was evaluated to measure the antidiabetic potential of three medicinal plants such as Tebengau (Ehretis laevis), Cemumar (Micromelum pubescens), and Kedondong (Spondias dulcis) and acarbose (commercial antidiabetic drug) via cyclic voltammetry, amperometry, and spectrophotometry. The cyclic voltammetry (CV) response for the inhibition of the AG enzyme activity by Tebengau plant extracts showed a linear relation in the range from 0.423–8.29 μA, and the inhibition detection limit was 0.253 μA. The biosensor exhibited good sensitivity (0.422 μA/mg Tebengau plant extracts) and rapid response (22 s). The biosensor retains approximately 82.16 % of its initial activity even after 30 days of storage at 4 °C.
14 September 2005 in Sensors and Actuators B: Chemical
Polyaniline (PANI) nanofibers with diameters ranging from 60 nm to 190 nm were successfully synthesized by rapid mixing polymerization method at room temperature. The effects of synthesis conditions such as concentration of hydrochloric acid (HCl), ammonium persulfate (APS), and aniline monomer (Ani) on the morphology of PANI nanofibers were investigated using scanning electron microscopy (SEM). FTIR and UV‐Vis analysis were performed to characterize the PANI nanofibers. The effect of polymerization time and electrical properties of PANI nanofibers was also discussed. A rapid mixing polymerization method is found to be advantageous in producing bulk quantities of nanofibers.
25 March 2021 in Semiconductor Science and Technology
The design of high-performance cavity for the accurate and efficient operation of various pH sensors remains challenging. In this paper, we report the simplistic design of an epoxy-free cavity with good quality contact effective for the extended gate field effect transistor (EGFET)-based pH sensors. This inexpensive, simple and leakage current free brass-based Teflon cavity was designed to separate the sensitive film devoid of the epoxy. The performance of the proposed cavity was assessed against four indium tin oxide (ITO) thin films (sensing membranes acted as pH sensors) of different sheet resistance by integrating into EGFET. The structure, morphology and sensing characteristics of these ITO membranes were determined as a function of varying resistance. The results revealed the formation of excellent electrical contacts and responses of these sensors to the changing pH values. The proposed pH sensors with the resistance of 2.5, 9.0, 15 and 35 kΩ showed the corresponding sensitivity of 34.86, 30, 16.66 and 17.5 mV pH −1 , respectively. It is asserted that the designed cavity may contribute towards the evolution of efficient sensing electrodes desired for diverse applications in the field of pH, biomedical, electrochemical and ions selective sensors.
α-glucosidase (AG) enzyme was immobilized onto amine functionalized multi-walled carbon nanotubes (MWCNTs-NH2) by treatment with cross linkers, 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS) via amide bonding. The immobilized AG was characterized by Fourier Transform Infrared Spectroscopy (FTIR) and Scanning Electron Microscope (SEM). The performance of the electrode was evaluated by Spectrophotometric method and cyclic voltammetric (CV) method using p-nitrophenyl-α-D-glucopyranoside (PNPG) as a substrate. The immobilized AG enzyme retains about 84.16% activity of its initial response even after 30 days when stored at 4°C.