In the last decade, there has been a steady stream of information on the methods and techniques available for detecting harmful algae species. The conventional approaches to identify harmful algal bloom (HAB), such as microscopy and molecular biological methods are mainly laboratory-based and require long assay times, skilled manpower, and pre-enrichment of samples involving various pre-experimental preparations. As an alternative, biosensors with a simple and rapid detection strategy could be an improvement over conventional methods for the detection of toxic algae species. Moreover, recent biosensors that involve the use of nanomaterials to detect HAB are showing further enhanced detection limits with a broader linear range. The improvement is attributed to nanomaterials’ high surface area to volume ratio, excellent biological compatibility with biomolecules, and being capable of amplifying the electrochemical signal. Hence, this review presents the potential usage of biosensors over conventional methods to detect HABs. The methods reported for the detection of harmful algae species, ranging from conventional detection methods to current biosensor approaches will be discussed, along with their respective advantages and drawbacks to indicate the future prospects of biosensor technology for HAB event management.
A high-performance electrochemical sensing platform inspired by a functional ‘green’ electrochemical reduction pathway was developed to identify and detect circulating tumor DNA (ctDNA) of gastric carcinoma in peripheral blood. The assembly of the biosensor, consisting of graphene oxide-wrapped gold nanostars (GO-AuNSs), was fabricated on a glassy carbon electrode using the surface chemistry of ‘layer-by-layer’ modification via an electrochemical route. The electrodeposition of the GO-AuNS nanocomposite on the electrode's surface effectively improved its electrochemical response and enhanced its immobilization pathway. At the same time, it demonstrated the electrochemical phenomena caused by DNA immobilization and hybridization events sans complex labelling or other indicators. The immobilization of the probe DNA occurred due to the π–π (weak) interactions between the GO-AuNS composite and the DNA bases. The hybridization of the probe DNA with ctDNA resulted in the formation of a helix structure, which precipitated the release of the resulting dsDNA from the electrode's surface. The immobilization and hybridization events caused a ‘signal off’ and ‘signal on’ model by respectively decreasing and increasing the signal current. The prepared composite nanostructure and the subsequently modified electrodes were characterized using Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM). The electrochemical response of the biosensor was elucidated using Differential Pulse Voltammetry (DPV), Cyclic Voltammetry (CV), and Electrochemical Impedance Spectroscopy (EIS). A linear relationship was established between the oxidation peak currents (DPV) and the different concentrations of ctDNA within the range of 1.0 × 10−20 M to 1.0 × 10−12 M (R2 = 0.998), with a detection limit (LOD) of 1.0 × 10−20 M (S/N = 3). The developed method shows translational prospects in ctDNA detection.
An ultrasensitive electrochemical biosensor for the determination of pathogenic Vibrio cholerae (V. cholerae) DNA was developed based on polystyrene-co-acrylic acid (PSA) latex nanospheres-gold nanoparticles composite (PSA-AuNPs) DNA carrier matrix. Differential pulse voltammetry (DPV) using an electroactive anthraquninone oligonucleotide label was used for measuring the biosensor response. Loading of gold nanoparticles (AuNPs) on the DNA-latex particle electrode has significantly amplified the faradaic current of DNA hybridisation. Together with the use of a reported probe, the biosensor has demonstrated high sensitivity. The DNA biosensor yielded a reproducible and wide linear response range to target DNA from 1.0 × 10−21 to 1.0 × 10−8 M (relative standard deviation, RSD = 4.5%, n = 5) with a limit of detection (LOD) of 1.0 × 10−21 M (R 2 = 0.99). The biosensor obtained satisfactory recovery values between 91 and 109% (n = 3) for the detection of V. cholerae DNA in spiked samples and could be reused for six consecutive DNA assays with a repeatability RSD value of 5% (n = 5). The electrochemical biosensor response was stable and maintainable at 95% of its original response up to 58 days of storage period.
The present research describes a simple method for the identification of the gender of arowana fish (Scleropages formosus). The DNA biosensor was able to detect specific DNA sequence at extremely low level down to atto M regimes. An electrochemical DNA biosensor based on acrylic microsphere-gold nanoparticle (AcMP-AuNP) hybrid composite was fabricated. Hydrophobic poly(n-butylacrylate-N-acryloxysuccinimide) microspheres were synthesised with a facile and well-established one-step photopolymerization procedure and physically adsorbed on the AuNPs at the surface of a carbon screen printed electrode (SPE). The DNA biosensor was constructed simply by grafting an aminated DNA probe on the succinimide functionalised AcMPs via a strong covalent attachment. DNA hybridisation response was determined by differential pulse voltammetry (DPV) technique using anthraquinone monosulphonic acid redox probe as an electroactive oligonucleotide label (Table 1). A low detection limit at 1.0 × 10−18 M with a wide linear calibration range of 1.0 × 10−18 to 1.0 × 10−8 M (R 2 = 0.99) can be achieved by the proposed DNA biosensor under optimal conditions. Electrochemical detection of arowana DNA can be completed within 1 hour. Due to its small size and light weight, the developed DNA biosensor holds high promise for the development of functional kit for fish culture usage.