Wojciech Dabrowski

Prof. Wojciech Dabrowski

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2021 in Science of The Total Environment
Verified
Journal Article
Open access
RŻRadosław Żyłka
Radosław Żyłka
BKBeata Karolinczak
Beata Karolinczak
WDWojciech Dabrowski
Wojciech Dabrowski
The aim of the research was to determine the indicators of electricity consumption in every stage of the dairy sewage treatment process in relation to the sewage flow and the load of removed organics (BOD5, COD) and nutrients (TN, TP). The research was conducted in a dairy wastewater treatment plant (WWTP) consisting of mechanical treatment, averaging tank, dissolved air flotation (DAF) and biological treatment with sequence batch reactors (SBRs). Energy consumption was measured with the help of transducers. Indicators of unit electricity consumption were determined on the basis of 95 measurement series of energy consumption, sewage flow and removed load. The mean value of total unit energy consumption relating to the flow for the entire WWTP was 2.29 kWh·m-3, while for biological treatment 1.17 kWh·m-3 and 0.05 kWh·m-3 for DAF. The mean values of indicators relating to removed pollutants load for the entire WWTP were: 1.89 kWh·kgrem BOD5-1, 1.30 kWh·kgrem COD-1, 48.61 kWh·kgrem TN-1 and 160.01 kWh·kgrem TP-1. During biological treatment, energy consumption indicators were on average: 1.65 kWh·kgrem BOD5-1 and 1.19 kWh·kgrem COD-1, 52.90 kWh·kgrem TN-1 and 141.26 kWh·kgrem TP-1, while for DAF: 0.12 kWh·kgrem BOD5-1, 0.09 kWh·kgrem COD -1, 3.85 kWh·kgrem TN-1 and 16.17 kWh·kgrem TP-1. It was found that the biological treatment in SBRs was responsible for 54.1% of the total energy consumption of dairy WWTP. Aerobic sewage sludge treatment accounted for 17.0% of total consumption, mechanical treatment 17.1%, deodorization 2.6%, and other (social, lighting etc.) 6.9%, while DAF only 2.3%. The real-time electricity metering system enabled the optimisation of the electricity consumption in the WWTP, taking into account its consumption in unit processes and the removed pollutants load. The application of this system enabled to make corrections that reduced energy consumption while maintaining the required treatment efficiency.

1 February 2017 in Environmental Research
Verified
Journal Article
Closed access
WDWojciech Dabrowski
Wojciech Dabrowski
RŻRadosław Żyłka
Radosław Żyłka
PMPaweł Malinowski
Paweł Malinowski

21 January 2019 in Water
Verified
Journal Article
Open access
PDF file
WDWojciech Dabrowski
Wojciech Dabrowski
BKBeata Karolinczak
Beata Karolinczak
PMPaweł Malinowski
Paweł Malinowski
DBDariusz Boruszko
Dariusz Boruszko
Reject water is a by-product of every municipal and agro-industrial wastewater treatment plant (WWTP) applying sewage sludge stabilization. It is usually returned without pre-treatment to the biological part of WWTP, having a negative impact on the nitrogen removal process. The current models of pollutants removal in constructed wetlands concern municipal and industrial wastewater, whereas there is no such model for reject water. In the presented study, the results of treatment of reject water from dairy WWTP in subsurface vertical flow (SS VF) and subsurface horizontal flow (SS HF) beds were presented. During a one-year research period, SS VF bed reached 50.7% efficiency of TN removal and 73.8% of NH4+-N, while SS HF bed effectiveness was at 41.4% and 62.0%, respectively. In the case of BOD5 (biochemical oxygen demand), COD (chemical oxygen demand), NH4+-N, and TN (total nitrogen), the P-k-C* model was applied. Multi-model nonlinear segmented regression analysis was performed. Final mathematical models with estimates of parameters determining the treatment effectiveness were obtained. Treatment efficiency increased up to the specific temperature, then it was constant. The results obtained in this work suggest that it may be possible to describe pollutant removal behavior using simplified models. In the case of TP (total phosphorus) removal, distribution tests along with a t-test were performed. All models predict better treatment efficiency in SS VF bed, except for TP.

1 July 2018 in Journal of Ecological Engineering
Verified
Journal Article
Open access
RŻRadosław Marcin Żyłka
Radosław Marcin Żyłka
WDWojciech Dabrowski
Wojciech Dabrowski
EGElena Gogina
Elena Gogina
OYOlga Yancen
Olga Yancen
The article presents the results of research on the possibility of using a trickling filter for high efficiency treatment of dairy sewage. Nowadays, up to the authors’ knowledge, it is possible to change activated sludge system to trickling filter technology, especially in small dairy plants...

6 June 2016 in Environmental Technology
Verified
Journal Article
Closed access
WDWojciech Dabrowski
Wojciech Dabrowski
BKBeata Karolinczak
Beata Karolinczak
MGMagdalena Gajewska
Magdalena Gajewska
Ewa WojciechowskaEwa Wojciechowska
Ewa Wojciechowska
The paper presents the effects of applying subsurface vertical flow constructed wetlands (SS VF) for the treatment of reject water generated in the process of aerobic sewage sludge stabilization in the biggest dairy wastewater treatment plant (WWTP) in Poland. Two SS VF beds were built: bed (A) with 0.65 m depth and bed (B) with 1.0 m depth, planted with reeds. Beds were fed with reject water with hydraulic load of 0.1 m d−1 in order to establish the differences in treatment efficiency. During an eight-months research period, a high removal efficiency of predominant pollutants was shown: BOD5 88.1% (A) and 90.5% (B); COD 84.5% (A) and 87.5% (B); TSS 87.6% (A) and 91.9% (B); TKN 82.4% (A) and 76.5% (B); N-NH4+ 89.2% (A) and 85.7% (B); TP 30.2% (A) and 40.6% (B). There were not statistically significant differences in the removal efficiencies between bed (B) with 1.0 m depth and bed (A) with 0.65 m depth. The research indicated that SS VF beds could be successfully applied to reject water treatment in dairy WWTPs. The study proved that the use of SS VF beds in full scale in dairy WWTPs would result in a significant decrease in pollutants’ load in reject water. In the analyzed case, decreasing the load of ammonia nitrogen was of greatest importance, as it constituted 58% of the total load treated in dairy WWTP and posed a hazard to the stability of the treatment process.

22 July 2020 in Energies
Verified
Journal Article
Open access
PDF file
RŻRadosław Żyłka
Radosław Żyłka
WDWojciech Dabrowski
Wojciech Dabrowski
PMPaweł Malinowski
Paweł Malinowski
BKBeata Karolinczak
Beata Karolinczak
The intensification of biological wastewater treatment requires the high usage of electric energy, mainly for aeration processes. Publications on energy consumption have been mostly related to municipal wastewater treatment plants (WWTPs). The aim of the research was to elaborate on models for the estimation of energy consumption during dairy WWTP operation. These models can be used for the optimization of electric energy consumption. The research was conducted in a dairy WWTP, operating with dissolved air flotation (DAF) and an activated sludge system. Energy consumption was measured with the help of three-phase network parameter transducers and a supervisory control and data acquisition (SCADA) system. The obtained models provided accurate predictions of DAF, biological treatment, and the overall WWTP energy consumption using chemical oxygen demand (COD), sewage flow, and air temperature. Using the energy consumption of the biological treatment as an independent variable, as well as air temperature, it is possible to estimate the variability of the total electric energy consumption. During the summer period, an increase in the organic load (expressed as COD) discharged into the biological treatment causes higher electric energy consumption in the whole dairy WWTP. Hence, it is recommended to increase the efficiency of the removal of organic pollutants in the DAF process. An application for the estimation of energy consumption was created.