Beata Karolinczak

Dr. Beata Karolinczak

Faculty of Building Services, Hydro and Environmental Engineering, Warsaw University of Technology, 00-661 Warsaw, Poland
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2021 in Science of The Total Environment
Verified
Journal Article
Open access
RŻRadosław Żyłka
Radosław Żyłka
BKBeata Karolinczak
Beata Karolinczak
WDWojciech Dabrowski
Wojciech Dabrowski
The aim of the research was to determine the indicators of electricity consumption in every stage of the dairy sewage treatment process in relation to the sewage flow and the load of removed organics (BOD5, COD) and nutrients (TN, TP). The research was conducted in a dairy wastewater treatment plant (WWTP) consisting of mechanical treatment, averaging tank, dissolved air flotation (DAF) and biological treatment with sequence batch reactors (SBRs). Energy consumption was measured with the help of transducers. Indicators of unit electricity consumption were determined on the basis of 95 measurement series of energy consumption, sewage flow and removed load. The mean value of total unit energy consumption relating to the flow for the entire WWTP was 2.29 kWh·m-3, while for biological treatment 1.17 kWh·m-3 and 0.05 kWh·m-3 for DAF. The mean values of indicators relating to removed pollutants load for the entire WWTP were: 1.89 kWh·kgrem BOD5-1, 1.30 kWh·kgrem COD-1, 48.61 kWh·kgrem TN-1 and 160.01 kWh·kgrem TP-1. During biological treatment, energy consumption indicators were on average: 1.65 kWh·kgrem BOD5-1 and 1.19 kWh·kgrem COD-1, 52.90 kWh·kgrem TN-1 and 141.26 kWh·kgrem TP-1, while for DAF: 0.12 kWh·kgrem BOD5-1, 0.09 kWh·kgrem COD -1, 3.85 kWh·kgrem TN-1 and 16.17 kWh·kgrem TP-1. It was found that the biological treatment in SBRs was responsible for 54.1% of the total energy consumption of dairy WWTP. Aerobic sewage sludge treatment accounted for 17.0% of total consumption, mechanical treatment 17.1%, deodorization 2.6%, and other (social, lighting etc.) 6.9%, while DAF only 2.3%. The real-time electricity metering system enabled the optimisation of the electricity consumption in the WWTP, taking into account its consumption in unit processes and the removed pollutants load. The application of this system enabled to make corrections that reduced energy consumption while maintaining the required treatment efficiency.

18 October 2023 in Science of The Total Environment
Verified
Journal Article
Open access
BKBeata Karolinczak
Beata Karolinczak
JWJustyna Walczak
Justyna Walczak
MBMagdalena Bogacka
Magdalena Bogacka
MZMonika Zubrowska-Sudol
Monika Zubrowska-Sudol
Wastewater treatment plants (WWTPs) aim to increase energy independence by intensifying biogas production. The study involved Life Cycle Assessment (LCA) comparing sewage sludge (SS) anaerobic co-digestion (AcD) with the organic fraction of municipal solid waste (OFMSW) at WWTP against SS anaerobic mono-digestion (AD). The LCA was based on the authors' research showing that methane production related to wet mass in AcD was higher than in AD by 86.4, 225.8, and 354.3 % for SS:OFMSW mixing ratios of 75:25, 50:50, and 25:75, respectively. The LCA was conducted for 1 kWh of biogas energy produced at a WWTP and included two subsystems: energy production (AD/AcD and CHP) and associated digestate management (drying, incineration with energy reuse, residual landfilling). CML-IA baseline 2013 and Recipe 2016 Midpoint (H) LCIA methodologies indicated the environmental impacts on abiotic depletion - fossil fuels (fossil resource scarcity), global warming, human toxicity (non-carcinogenic), freshwater, and marine aquatic ecotoxicity. AD of SS in all categories was characterized by the highest impact. The impact decreased with an increase in the OFMSW rate. Both methodologies showed a significant impact of AD and AcD on global warming, which indicated the need for the determination of the carbon footprint (CF) of 1kWh biogas energy production (gCO2 kWh-1) at WWTP, using IPCC 2021 GWP100 (incl. CO2 uptake). The CF was the highest for biogas energy production in SS AD (1509 gCO2 kWh-1) and it decreased with the increase of OFMSW content in AcD (872-481 gCO2 kWh-1). This was also observed for the management of associated digestate. CF changed from 1508 gCO2 kWh-1 for SS AD to 396 gCO2 kWh-1 for SS: OFMSW mixing ratio of 25: 75 in AcD. The environmental burdens associated with biogas energy production and digestate management were equally significant. Finally, the formula for economic and ecological comparison of SS AD and AcD with OFMSW was proposed.

21 January 2019 in Water
Verified
Journal Article
Open access
PDF file
WDWojciech Dabrowski
Wojciech Dabrowski
BKBeata Karolinczak
Beata Karolinczak
PMPaweł Malinowski
Paweł Malinowski
DBDariusz Boruszko
Dariusz Boruszko
Reject water is a by-product of every municipal and agro-industrial wastewater treatment plant (WWTP) applying sewage sludge stabilization. It is usually returned without pre-treatment to the biological part of WWTP, having a negative impact on the nitrogen removal process. The current models of pollutants removal in constructed wetlands concern municipal and industrial wastewater, whereas there is no such model for reject water. In the presented study, the results of treatment of reject water from dairy WWTP in subsurface vertical flow (SS VF) and subsurface horizontal flow (SS HF) beds were presented. During a one-year research period, SS VF bed reached 50.7% efficiency of TN removal and 73.8% of NH4+-N, while SS HF bed effectiveness was at 41.4% and 62.0%, respectively. In the case of BOD5 (biochemical oxygen demand), COD (chemical oxygen demand), NH4+-N, and TN (total nitrogen), the P-k-C* model was applied. Multi-model nonlinear segmented regression analysis was performed. Final mathematical models with estimates of parameters determining the treatment effectiveness were obtained. Treatment efficiency increased up to the specific temperature, then it was constant. The results obtained in this work suggest that it may be possible to describe pollutant removal behavior using simplified models. In the case of TP (total phosphorus) removal, distribution tests along with a t-test were performed. All models predict better treatment efficiency in SS VF bed, except for TP.

6 June 2016 in Environmental Technology
Verified
Journal Article
Closed access
WDWojciech Dabrowski
Wojciech Dabrowski
BKBeata Karolinczak
Beata Karolinczak
MGMagdalena Gajewska
Magdalena Gajewska
Ewa WojciechowskaEwa Wojciechowska
Ewa Wojciechowska
The paper presents the effects of applying subsurface vertical flow constructed wetlands (SS VF) for the treatment of reject water generated in the process of aerobic sewage sludge stabilization in the biggest dairy wastewater treatment plant (WWTP) in Poland. Two SS VF beds were built: bed (A) with 0.65 m depth and bed (B) with 1.0 m depth, planted with reeds. Beds were fed with reject water with hydraulic load of 0.1 m d−1 in order to establish the differences in treatment efficiency. During an eight-months research period, a high removal efficiency of predominant pollutants was shown: BOD5 88.1% (A) and 90.5% (B); COD 84.5% (A) and 87.5% (B); TSS 87.6% (A) and 91.9% (B); TKN 82.4% (A) and 76.5% (B); N-NH4+ 89.2% (A) and 85.7% (B); TP 30.2% (A) and 40.6% (B). There were not statistically significant differences in the removal efficiencies between bed (B) with 1.0 m depth and bed (A) with 0.65 m depth. The research indicated that SS VF beds could be successfully applied to reject water treatment in dairy WWTPs. The study proved that the use of SS VF beds in full scale in dairy WWTPs would result in a significant decrease in pollutants’ load in reject water. In the analyzed case, decreasing the load of ammonia nitrogen was of greatest importance, as it constituted 58% of the total load treated in dairy WWTP and posed a hazard to the stability of the treatment process.

22 July 2020 in Energies
Verified
Journal Article
Open access
PDF file
RŻRadosław Żyłka
Radosław Żyłka
WDWojciech Dabrowski
Wojciech Dabrowski
PMPaweł Malinowski
Paweł Malinowski
BKBeata Karolinczak
Beata Karolinczak
The intensification of biological wastewater treatment requires the high usage of electric energy, mainly for aeration processes. Publications on energy consumption have been mostly related to municipal wastewater treatment plants (WWTPs). The aim of the research was to elaborate on models for the estimation of energy consumption during dairy WWTP operation. These models can be used for the optimization of electric energy consumption. The research was conducted in a dairy WWTP, operating with dissolved air flotation (DAF) and an activated sludge system. Energy consumption was measured with the help of three-phase network parameter transducers and a supervisory control and data acquisition (SCADA) system. The obtained models provided accurate predictions of DAF, biological treatment, and the overall WWTP energy consumption using chemical oxygen demand (COD), sewage flow, and air temperature. Using the energy consumption of the biological treatment as an independent variable, as well as air temperature, it is possible to estimate the variability of the total electric energy consumption. During the summer period, an increase in the organic load (expressed as COD) discharged into the biological treatment causes higher electric energy consumption in the whole dairy WWTP. Hence, it is recommended to increase the efficiency of the removal of organic pollutants in the DAF process. An application for the estimation of energy consumption was created.

28 August 2021 in Energies
Verified
Journal Article
Open access
PDF file
BKBeata Karolinczak
Beata Karolinczak
WDWojciech Dabrowski
Wojciech Dabrowski
RŻRadosław Żyłka
Radosław Żyłka
Modernisation of municipal and industrial wastewater treatment plants (WWTPs) should be carried out, taking into account its impact on global warming, e.g., through carbon footprint (CF) analysis. An important industrial sector in Poland is the dairy industry. In dairy WWTPs, the aerobic sewage sludge stabilisation applied thus far is being replaced by the anaerobic process. This change is positive due to the possibility of energy production, but it is unclear how it affects greenhouse gases (GHG) emissions. The aim of the research was to perform CF analysis for two scenarios of dairy WWTP operation. The analysis was based on the real operating data of the current system (current scenario) and project of its modernisation (alternative scenario). The current scenario consists of mechanical and dissolved air flotation (DAF) treatment, biological treatment in sequence batch reactors (SBRs), aerobic sewage sludge stabilisation and its final farmland usage. The alternative scenario assumes replacing aerobic stabilisation with anaerobic stabilisation and a combined heat and power (CHP) system. The CF calculations were based on empirical models, taking into account different emission input parameters, expressed in CO2 equivalents (CO2e). The total CF of the current scenario was 22 kg CO2e PE−1 year−1, while the alternative was 45 kg CO2e PE−1 year−1. The largest share in the current scenario belongs to emissions from WWTPs and energy use, while in the alternative, there is the addition of emissions from biogas use.