Purpose: The novel metallic damper device for passive vibration control of structures, which is designed primarily for seismic protection of buildings, is described in this paper. It consists of the base plate, fixed into foundation, with two concentric cycles of vertical components and a middle steel activating plate anchored to the isolated structure. During an earthquake, the middle steel activating plate moves together with main structure causing bending of vertical components. Seismic energy is absorbed due to plastic deformation of the vertical components of the damper. The performance of various vertical components, the key elements of the novel damper is studied in this paper. The advantages of this type of damper reflect in its ability to adapt its own features depending on the intensity of the earthquake and that it has equivalent characteristics in every horizontal direction due to rotational symmetry. Methods: Sixteen experimental tests of the vertical components of the damper, were conducted to obtain their hysteretic behaviour. Numerical models using the finite element method and the Abaqus/Standard software were developed, validated and verified with experimentally obtained results. Results: The experimental results show significant energy absorption of the vertical components of the novel damper. Numerical models can be used in further research instead of expensive experimental tests. Conclusions: The vertical components of the novel damper possess extraordinary hysteretic performance. If the components of the energy dissipation device are properly designed for maximum displacements, the device is not expected to suffer heavy damage or total failure during earthquakes.
Strengthening of concrete structures is applied as a solution for various deterioration problems in civil engineering practice. This also refers to the structures made of self-compacting concrete (SCC), which is increasingly in use, but there is a lack of research in this field. This paper presents an experimental analysis of flexural behavior of reinforced concrete (RC) continuous beams made of SCC, strengthened with fiber reinforced polymer (FRP) materials (glass (GFRP) and carbon (CFRP) bars, CFRP laminates), by the use of near surface mounted (NSM) and externally bonded (EB) methods. Six two-span continuous beams of a total length of 3200 mm, with the span between supports of 1500 mm and 120/200 mm cross section, were subjected to short-term load and tested. The displacements of beams and the strains in concrete, steel reinforcement, FRP bars and tapes were recorded until failure under a monotonically increasing load. The ultimate load capacities of the strengthened beams were enhanced by 22% to 82% compared to the unstrengthened control beam. The ductility of beams strengthened with GFRP bars was satisfactory, while the ductility of beams strengthened with CFRP bars and tapes was very small, so the failure modes of these beams were brittle.
Self-compacting concrete (SCC) is a type of concrete that is placed in the formwork under its own weight. Although there are many studies showing the behavior of SCC beams, most relate to the behavior of simple supported beams. Unlike those, this is a study of continuous beams made of SCC aimed to analyze their flexural performance as well as to confirm the possibility of using nonlinear finite element analysis (FEA) in the design of such structural elements. An experimental study of three two-span continuous beams of a total length of 3400 mm, with the span between supports of 1600 mm, with 150/200 mm cross section made of SCC exposed to short-term loading, was carried out. The parameter that varied is the percentage of tensile reinforcement, with values of 0.65, 0.86 and 0.94 being selected. As all analyzed beams have shown a satisfactory load-bearing capacity and stiffness, the research confirmed the possibility of using SCC in continuous beams in civil engineering practice. Using Abaqus/Standard software, a nonlinear numerical model is proposed, which is validated and verified against experimental research, as there is only a 5% difference in the numerically calculated ultimate load compared to the experimentally measured values.
1 January 2011 in Facta universitatis - series: Architecture and Civil Engineering
The structures with semi-rigid connections comprise systems with the connections in joints which are not absolutely rigid, but allow, in general, some relative movements in directions of generalized displacements. Such type of connections is considered very little, or not at all, in designing of structures in today's engineering practice. If the influence of rigidity of semi-rigid connections is underestimated, and they are treated in the design as pinned, it has a negative impact on cost of a structure. But if it is overstated, the calculation results are not on the side of safety, what is reflected on bearing capacity, durability and stability, especially in the case of precast structures. Therefore Eurocodes take due account to the structures with semi-rigid connections. Matrix formulation of the analysis of systems with semi-rigid connections opens wide possibilities for relatively easy calculation by use of computers that is shown by example of seismic design. The interpolation functions, stiffness matrix, equivalent load vectors, and the consistent mass matrix are presented in this paper, particularly with an emphasis on systems with semi-rigid connection.
1
1 January 2010 in Facta universitatis - series: Architecture and Civil Engineering
The paper presents a brief description of experiment within the research project 'Theoretical and experimental analysis of interaction of shallow reinforced concrete foundations and soil for the purpose of improvement of national regulations and implementaation of Eurocode system' where in situ tests of a series of reinforced concrete foundation footing were performed, by loading until failure. As a rule, methods for calculation of shallow foundations settlement on granular soils overestimate the expected settlement, and underestimate soil bearing capacity, which results in a conservative foundation design. In order to test accuracy and reliability of the different settlements prediction methods, a comparative analysis of settlements calculated using these methods and those measured during experiment, was performed.
1 January 2010 in Facta universitatis - series: Architecture and Civil Engineering
Most often, in the case of typefied prefabricated systems, foundations are designed and constructed as prefabricated elements as well. When the structure is exposed to high intensity loading and founded on a weak soil, beam foundations are often used instead of pad foundations. Beam foundations, stiffening girders, as well as beams which support the fa?ade elements or partition walls, are treated as beams on elastic foundations, while joint of these girders to pad foundations or vertical support elements of a precast structure can be treated as semi-rigid. Modeling of systems with semi-rigid joints on elastic foundations, for different levels of rigidity of connections, is illustrated by an example of a frame under static loading. On the basis of the results of the calculation carried out in this paper, it is evident that taking into account the elastic foundations of the member and the corresponding degree of fixation of the member on this foundations significantly affects the magnitude of the forces in the cross-sections of the member, and on the redistribution of influences in the entire structure. Yet, the foundations-and-soil interaction exerted the highest influence on the magnitude of the stress in the foundation structure itself.