Shao-Ku Kao

Prof. Dr. Shao-Ku Kao

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 March 2023 in British Journal of Radiology
Verified
Journal Article
Open access
Chi-Tung ChengChi-Tung Cheng
Chi-Tung Cheng
CHChih-Po Hsu
Chih-Po Hsu
OCOuyang Chunghsiang
Ouyang Chunghsiang
CCChia-Yi Chou
Chia-Yi Chou
NLNai-Yu Lin
Nai-Yu Lin
ChienHung LiaoChienHung Liao
ChienHung Liao
Objective: To identify the feasibility and efficiency of deep convolutional neural networks (DCNNs) in the detection of ankle fractures and to explore ensemble strategies that applied multiple projections of radiographs. Ankle radiographs (AXRs) are the primary tool used to diagnose ankle fractures. Applying DCNN algorithms on AXRs can potentially improve the diagnostic accuracy and efficiency of detecting ankle fractures. Methods: A DCNN was trained using a trauma image registry, including 3102 AXRs. We separately trained the DCNN on anteroposterior (AP) and lateral (Lat) AXRs. Different ensemble methods, such as “sum-up,” “severance-OR,” and “severance-Both,” were evaluated to incorporate the results of the model using different projections of view. Results: The AP/Lat model’s individual sensitivity, specificity, positive-predictive value, accuracy, and F1 score were 79%/84%, 90%/86%, 88%/86%, 83%/85%, and 0.816/0.850, respectively. Furthermore, the area under the receiver operating characteristic curve (AUROC) of the AP/Lat model was 0.890/0.894 (95% CI: 0.826–0.954/0.831–0.953). The sum-up method generated balanced results by applying both models and obtained an AUROC of 0.917 (95% CI: 0.863–0.972) with 87% accuracy. The severance-OR method resulted in a better sensitivity of 90%, and the severance-Both method obtained a high specificity of 94%. Conclusion: Ankle fracture in the AXR could be identified by the trained DCNN algorithm. The selection of ensemble methods can depend on the clinical situation which might help clinicians detect ankle fractures efficiently without interrupting the current clinical pathway. Advances in knowledge: This study demonstrated different ensemble strategies of AI algorithms on multiple view AXRs to optimize the performance in various clinical needs.

8 March 2022 in IEEE Access
Verified
Journal Article
Open access
SKShao-Ku Kao
Shao-Ku Kao
JCJian-Jiun Chen
Jian-Jiun Chen
CLChien-Hung Liao
Chien-Hung Liao
A multipath output-capacitor-less low-dropout (OCL-LDO) regulator with feedforward path compensation is presented to achieve low power consumption and fast transient response. The proposed OCL-LDO does not require output capacitance and remains stable at no-load(under 100nA) condition. The proposed OCL-LDO regulator has been implemented and fabricated in a $0.18\mu \text{m}$ CMOS process, it occupies an active area of 0.0128mm 2 . The proposed circuit consumes a quiescent current of $0.6\mu \text{A}$ at no load and $6.9\mu \text{A}$ at the maximum current load current. Regulating the output at 1V from a voltage supply of 1.2V. It achieves full range stability from 100nA to 100mA, and 100pF is the maximum tolerable parasitic capacitance at output. The measurement results show that the load current rises from 0 to 100mA in 100ns, the undershoot voltage is 388mV, and the settling time is $2.2\mu \text{s}$ .

8 May 2024 in IEEE Access
Verified
Journal Article
Open access
SKShao-Ku Kao
Shao-Ku Kao
JCJian-Jiun Chen
Jian-Jiun Chen
CLChien-Hung Liao
Chien-Hung Liao
YLYu-Jen Lu
Yu-Jen Lu
Jer-Chyi WangJer-Chyi Wang
Jer-Chyi Wang
An output capacitorless low-dropout (OCL-LDO) regulator with a direct-coupled slew rate enhancement (DCSRE) technique. This paper proposes a low-dropout regulator with a simple structure, fast transient response, and the ability to reduce overshoot and undershoot, suitable for system-on-chip (SOC) integration. Instead of a high-pass filter, an error amplifier is used to couple the transient signal to achieve better transient response with higher current efficiency and no significant increase in chip area and power consumption, eliminating the tradeoff with the high-pass filter cutoff frequency and simplifying design considerations. Furthermore, the proposed technique would not affect other characteristics of the LDO regulator such as stability, frequency compensation, line regulation, and load regulation. In addition, the analysis is carried out for the case of many poles and zeros in the unity-gain bandwidth (GBW). From the measurement result, the proposed LDO regulator regulated the output voltage at 1 V from the input range 1.8V up to 3.3V, with $28.8\mu $ A quiescent. The output voltage recovers in $0.23\mu $ s at a voltage spike of less than 43.5mV, where the load current switches from $100\mu $ A to 100mA in 100ns. The LDO regulator is fabricated in a $0.18\mu $ m CMOS process with a core area of 0.0174mm2.

4 August 2015 in International Journal of Circuit Theory and Applications
Verified
Journal Article
Closed access
PDF file
SKShao-Ku Kao
Shao-Ku Kao
YHYi‐Hsien Hsieh
Yi‐Hsien Hsieh
HCHsiang‐Chi Cheng
Hsiang‐Chi Cheng

13 April 2021 in IEEE Nanotechnology Magazine
Verified
Journal Article
Closed access
CLChao-Sung Lai
Chao-Sung Lai
BSBing Sheu
Bing Sheu
KLKin Fong Lei
Kin Fong Lei
HYHui-Ying Yang
Hui-Ying Yang
SKShao-Ku Kao
Shao-Ku Kao

1 October 2015 in Microelectronics Journal
Verified
Journal Article
Closed access
SKShao-Ku Kao
Shao-Ku Kao
JWJen-Hou Wu
Jen-Hou Wu
HCHsiang-Chi Cheng
Hsiang-Chi Cheng