Dramatic cost savings, safety improvements and accelerated nuclear decommissioning are all possible through the application of robotic solutions. Remotely-controlled systems with modern sensing capabilities, actuators and cutting tools have the potential for use in extremely hazardous environments, but operation in facilities used for handling radioactive material presents complex challenges for electronic components. We present a methodology and results obtained from testing in a radiation cell in which we demonstrate the operation of a robotic arm controlled using modern electronics exposed at 10 Gy/h to simulate radioactive conditions in the most hazardous nuclear waste handling facilities.
We measured the radiation tolerance of commercially available diamonds grown by the Chemical Vapor Deposition process by measuring the charge created by a 120 GeV hadron beam in a 50 pitch strip detector fabricated on each diamond sample before and after irradiation. We irradiated one group of samples with 70 MeV protons, a second group of samples with fast reactor neutrons (defined as energy greater than MeV), and a third group of samples with 200 MeV pions, in steps, to () × 1015 protons/cm2, () × 1016 neutrons/cm2, and () × 1014 pions/cm2, respectively. By observing the charge induced due to the separation of electron–hole pairs created by the passage of the hadron beam through each sample, on an event-by-event basis, as a function of irradiation fluence, we conclude all datasets can be described by a first-order damage equation and independently calculate the damage constant for 70 MeV protons, fast reactor neutrons, and 200 MeV pions. We find the damage constant for diamond irradiated with 70 MeV protons to be 10−18 cm2, the damage constant for diamond irradiated with fast reactor neutrons to be 10−18 cm2, and the damage constant for diamond irradiated with 200 MeV pions to be 10−18 cm2. The damage constants from this measurement were analyzed together with our previously published 24 GeV proton irradiation and 800 MeV proton irradiation damage constant data to derive the first comprehensive set of relative damage constants for Chemical Vapor Deposition diamond. We find 70 MeV protons are 2.60 ± 0.29 times more damaging than 24 GeV protons, fast reactor neutrons are 4.3 ± 0.4 times more damaging than 24 GeV protons, and 200 MeV pions are 3.2 ± 0.8 more damaging than 24 GeV protons. We also observe the measured data can be described by a universal damage curve for all proton, neutron, and pion irradiations we performed of Chemical Vapor Deposition diamond. Finally, we confirm the spatial uniformity of the collected charge increases with fluence for polycrystalline Chemical Vapor Deposition diamond, and this effect can also be described by a universal curve.
With extensive remediation currently ongoing as a consequence of the Fukushima Daiichi Nuclear Power Plant accident, there exists the even greater need to provide a system with which the distribution of radiation (specifically radiocesium) can be rapidly determined across extensive areas, yet at high (meter or sub-meter) spatial resolutions. Although a range of potential survey methods have been utilised (e.g. fixed-wing aircraft, helicopter, vehicular and more-recently unmanned aerial vehicle) to characterise such radiation distributions, ground-based (on-foot) methods that employ human operatives to traverse sites of interest, remain one of the primary methods with which to perform routine radiological surveys. Through the application of a newly developed platform carried as a backpack-contained unit, it was possible to survey sites at twice the rate previously possible – reducing the overall exposure time of the operator to ionising radiation, as well as dramatically reducing the level of radiation attenuation (introduced by the operator) onto the detector. Alike to magnetometry survey platforms employed for ore prospecting applications, this boom-based system removed the requirement to perform lengthy and intricate corrections to the data to account for such gamma-ray interception, intensity reduction and spectral distortion.