Ai-Lin Liu

Prof. Dr. Ai-Lin Liu

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Acta Biomaterialia
Verified
Journal Article
Closed access
CZChengfei Zhao
Chengfei Zhao
XWXuewen Wang
Xuewen Wang
LYLuying Yu
Luying Yu
LWLina Wu
Lina Wu
XHXiaoli Hao
Xiaoli Hao
XLXinhua Lin
Xinhua Lin

1 January 2022 in Carbon
Verified
Journal Article
Closed access
LWLi-Na Wu
Li-Na Wu
YYYuan-Jie Yang
Yuan-Jie Yang
LHLin-Xiao Huang
Lin-Xiao Huang
YZYu Zhong
Yu Zhong
YCYao Chen
Yao Chen
ALAi-Lin Liu
Ai-Lin Liu


2 March 2018 in Nanoscale
Verified
Journal Article
Closed access
PDF file
HDHaohua Deng
Haohua Deng
KLKe-Lin Li
Ke-Lin Li
QZQuan-Quan Zhuang
Quan-Quan Zhuang
HPHua-Ping Peng
Hua-Ping Peng
QZQiong-Qiong Zhuang
Qiong-Qiong Zhuang
WCWei Chen
Wei Chen
Luminescent copper nanoclusters (CuNCs) constitute a very active research topic due to their unique properties and lower cost than gold and silver NCs. In this study, we report a new, facile, and rapid top-down etching method for synthesizing luminescent CuNCs, using Cu nanoparticles (CuNPs) as the precursor and ammonia (NH3) as the etchant. The etching mechanism is systematically investigated and the optical and structural properties of the obtained CuNCs are carefully studied. The NH3-triggered etching process is very fast and the newly generated CuNCs can emit strong green fluorescence with a high quantum yield. Moreover, by coupling the urease-catalyzed hydrolysis of urea with the NH3-induced etching of CuNPs, we developed a novel fluorescence turn-on assay for urea. The linear range for urea detection is from 0.25 to 5 mM, and the limit of detection is 0.01 mM. This novel sensing approach, with good sensitivity and excellent selectivity, is then successfully utilized to detect urea in human serum samples, demonstrating its great potential in clinical diagnosis. In addition, the proposed coupling method can be extended to monitor other analytes that influence the size-focusing etching process, allowing metal NCs to be used to construct diverse chemosensors and biosensors.

1 February 2020 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
MLMeng-Meng Liu
Meng-Meng Liu
SLShan-Hong Li
Shan-Hong Li
DHDan-Dan Huang
Dan-Dan Huang
ZXZhi-Wei Xu
Zhi-Wei Xu
YWYa-Wei Wu
Ya-Wei Wu
ALAi-Lin Liu
Ai-Lin Liu

1 January 2008 in Chemical and Pharmaceutical Bulletin
Verified
Journal Article
Closed access
PDF file
ALAi-Lin Liu
Ai-Lin Liu
SZShaobo Zhang
Shaobo Zhang
LHLiying Huang
Liying Huang
YCYangyuan Cao
Yangyuan Cao
HYHong Yao
Hong Yao
XLXinhua Lin
Xinhua Lin
Luteolin is a flavonoid reported to occur widely in many medicinal plants. The electrochemical behavior of luteolin was studied in phosphate buffer solution (PBS) of pH 4.0 at a glassy carbon electrode (GCE) by cyclic voltammetry (CV) and differential pulse voltammetric method (DPV). The results indicated the well-defined redox peak of luteolin which was involving two electrons and two protons was observed and the electrode process is adsorption-controlled. The charge transfer coefficient (α) was calculated as 0.66. The relationships between oxidation peak current and the concentration of luteolin are linear in the range of 1.0×10−8—1.0×10−6 M by DPV method. The detection limit had been estimated as 5.0×10−9 M. The facile and rapid method has been successfully applied to the detection of luteolin in tablets.