Piezoelectric energy harvesters have been extensively researched for use with wireless sensors or low power consumption electronic devices. Most of the piezoelectric energy harvesters cannot generate enough power for potential applications. In this study, we explore the parameters, including gap and proof mass, that can affect the damping of the cantilever to optimize the design of the energy harvester. A finite analysis is conducted using COMSOL Multiphysics software. Usually, this type of simulation is performed using the loss factor. However, it is known that results from the loss factor produce models that do not fit the experimental data well. In fact, the result of output voltage using the loss factor is 50% higher than the real value, which is due to ignoring the adverse effect of a superimposing mechanical damping of different constituent materials. In order to build a true model, Rayleigh damping coefficients are measured to use in a simulation. This resulted in a closer fit of modeling and experimental data, and a 5 times better output voltage from the optimized energy harvester compared with using the smallest gap and mass.
Education of students in electrical engineering must provide learning outcomes and enable the engineer of electrical engineering to work in the industry and use modern technological equipment with sophisticated automated electrotechnical equipment. Moreover, the learning process and its outcomes should provide students with the skills needed and appropriate for companies producing electrical, electronic and electromechanical equipment, including design, research and consulting. Due to this, the aim of this paper is to present an approach for efficient composition of lectures, practical work and individual work by correlating the different learning methodologies (like Problem-based learning) with mentoring process based on the design of prototypes. Such concept serves as a result of industry and academia collaboration and gives a new approach for the development of study programs based on future societal needs. The case study of electrical engineers' education on undergraduate and master level is presented in this paper as well.
19 November 2014 in Elektronika ir Elektrotechnika
Goal directed fluid therapy (GDFT) implies the flow-related parameters guided infusion of fluids. It requires adherence to complex clinical algorithms and fluid protocols, as well as simultaneous monitoring of several parameters and evaluation of their fluid responsiveness or actual response to fluid challenges. Automated clinical decision support systems (ACDSS) are used to ease the task. However, they are based on the flow-related (hemodynamic) parameters – arterial blood pressure, cardiac output, etc. Meanwhile, infusions guided by hemodynamic endpoints may lead to edema. A mini Volume Loading Test (mVLT) may be helpful in detection of imminent edema from changes in hemodilution during stepwise infusion which is conventionally used for hemodynamic optimization. We developed an ACDSS which is based on evaluation of both hemodynamic and hemodilution parameters. It operates on the basis of our unique algorithm which implies interchangeable application of fluid loading, vasopressor injection and red cell transfusion. This ACDSS is used in our PC-based command centre of a prototype semi-closed loop (SCL) infusion system. We developed a simulator – ‘Virtual Patient’ – on the basis of our previous clinical records aiming to test a new controller, as well as train the research team before starting a clinical trial. In silico testing continued for 12 hours on five occasions. Primary endpoint was the compliance of a controller with our clinical algorithm and the stability of operation in a spectrum of arterial hypotension and bleeding scenarios. The prototype SCL infusion system was found ready for clinical validation. DOI: http://dx.doi.org/10.5755/j01.eee.20.9.8520
12 November 2012 in Elektronika ir Elektrotechnika
Typical risk reduction measures are not sufficient to reduce the probability of errors resulting from operator mistakes. Improvement of the device software and hardware, adding more alerts and alarms is not enough to significantly reduce the risk of such type of hazards, so there is a need of new methods to improve the safety of medical devices. One of possible solutions – systems with closed loop control. Integrating patient monitoring and drug infusion devices in to integrated system and using a controller, which would be able to asses required changes in the infusion according to patients vital signs might make it possible to reduce the probability of hazards arising from the need of constant monitoring, overdose and lack of appropriate timely reaction when a problem occurs. Modelling of closed loop systems show that the objectives, such as constant blood pressure in post-operative patients, can be achieved. Mathematical modelling is not sufficient to evaluate all the environmental factors, but it is helpful to decide the complexity of the system needed in each case.DOI: http://dx.doi.org/10.5755/j01.eee.18.9.2802
About Me
Researcher interested in closed loop systems and engineering education
Researcher interested in closed loop systems and engineering education