Marcin Kafarski

Dr. Marcin Kafarski

Institute of Agrophysics, Polish Academy of Sciences
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Geoderma
Verified
Journal Article
Open access
ASAgnieszka Szypłowska
Agnieszka Szypłowska
ALArkadiusz Lewandowski
Arkadiusz Lewandowski
SYShin Yagihara
Shin Yagihara
HSHironobu Saito
Hironobu Saito
KFKahori Furuhata
Kahori Furuhata
WSWojciech Skierucha
Wojciech Skierucha

12 January 2017 in Measurement Science and Technology
Verified
Journal Article
Open access
PDF file
ALArkadiusz Lewandowski
Arkadiusz Lewandowski
ASAgnieszka Szypłowska
Agnieszka Szypłowska
MKMarcin Kafarski
Marcin Kafarski
AWAndrzej Wilczek
Andrzej Wilczek
PBPaweł Barmuta
Paweł Barmuta
WSWojciech Skierucha
Wojciech Skierucha

1 June 2021 in Measurement
Verified
Journal Article
Open access
JMJacek Majcher
Jacek Majcher
MKMarcin Kafarski
Marcin Kafarski
AWAndrzej Wilczek
Andrzej Wilczek
ASAgnieszka Szypłowska
Agnieszka Szypłowska
ALArkadiusz Lewandowski
Arkadiusz Lewandowski
WSWojciech Skierucha
Wojciech Skierucha

4 January 2018 in Sensors
Verified
Journal Article
Open access
PDF file
MKMarcin Kafarski
Marcin Kafarski
AWAndrzej Wilczek
Andrzej Wilczek
ASAgnieszka Szypłowska
Agnieszka Szypłowska
ALArkadiusz Lewandowski
Arkadiusz Lewandowski
PPPiotr Pieczywek
Piotr Pieczywek
WSWojciech Skierucha
Wojciech Skierucha
The observed dielectric spectrum of ripe apples in the last period of shelf-life was analyzed using a multipole dielectric relaxation model, which assumes three active relaxation processes: primary α-process (water relaxation) and two secondary processes caused by solid-water-ion interactions α’ (bound water relaxations), as well as β’ (Maxwell-Wagner effect). The performance of two designs of the dielectric probe was compared: a classical coaxial open-ended probe (OE probe) and an open-ended probe with a prolonged central conductor in a form of an antenna (OE-A-probe). The OE-A probe increases the measurement volume and consequently extends the range of applications to other materials, like granulated agricultural products, soils, or liquid suspensions. However, its measurement frequency range is limited as compared to the OE probe because, above 1.5 GHz, the probe with the antenna generates higher propagation modes and the applied calibrations and calculations are not sufficient. It was shown that data from measurements using the OE-A probe gave slightly stronger correlations with apples’ quality parameters than using the typical OE probe. Additionally, we have compared twelve multipole fitting models with different combinations of poles (eight three-pole and four two-pole models). It was shown that the best fit is obtained using a two-pole model for data collected for the OE-A probe and a three-pole model for the OE probe, using only Cole-Cole poles in both cases.

4 February 2016 in Sensors
Verified
Journal Article
Open access
PDF file
AWAndrzej Wilczek
Andrzej Wilczek
ASAgnieszka Szypłowska
Agnieszka Szypłowska
MKMarcin Kafarski
Marcin Kafarski
WSWojciech Skierucha
Wojciech Skierucha
Time-domain reflectometry (TDR) methods used for measuring the dielectric properties of materials mostly utilize step or needle electrical pulses of constant amplitudes and shapes. Our novel approach enables determining the dielectric relaxation time of a sample using the analysis of the amplitudes of reflected pulses of two widths, in addition to bulk dielectric permittivity and electrical conductivity commonly obtained by the TDR technique. The method was developed for various values of electrical conductivity and relaxation time using numerical simulations of a five-rod probe placed in a material with complex dielectric permittivity described by the Debye model with an added electrical conductivity term. The characterization of amplitudes of two pulses of selected widths was done with regard to the dielectric parameters of simulated materials. The required probe parameters were obtained solely from numerical simulations. Verification was performed for the probe placed in aqueous KCl solutions with 14 different electrical conductivity values. The determined relaxation time remained roughly constant and independent of electrical conductivity. The obtained electrical conductivity agreed with the reference values. Our results indicate that the relaxation time, dielectric permittivity and electrical conductivity of the tested solutions can be simultaneously determined using a simple analysis of the amplitude and reflection time of two needle pulses of different widths.

22 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
JMJacek Majcher
Jacek Majcher
MKMarcin Kafarski
Marcin Kafarski
AWAndrzej Wilczek
Andrzej Wilczek
AWAleksandra Woszczyk
Aleksandra Woszczyk
ASAgnieszka Szypłowska
Agnieszka Szypłowska
WSWojciech Skierucha
Wojciech Skierucha
Soil volumetric water content (θ) is a parameter describing one of the most important factors conditioning proper plant growth. Monitoring soil moisture is of particular importance in the rational use of water resources for irrigation, especially during periods of water scarcity. This paper presents a method of measuring soil moisture in the vicinity of the plant root system by means of a probe designed to be mounted on a mobile device used for precise plant irrigation. Due to the specific field conditions of the measurement, the design of the probe was proposed as a monopole antenna. Electromagnetic simulations of the probe were carried out with Ansys HFSS software to optimise its dimensions. Then a prototype of the probe was manufactured to conduct laboratory measurements with the use of a vector network analyser (VNA) working in the 20 kHz to 8 GHz frequency range. The VNA analyser was configured to work in the time-domain reflectometry (TDR) mode. From measurements of the time distance between reflections from the probe’s elements it is possible to calculate the bulk dielectric permittivity of the soil surrounding the probe. Next, based on commonly used soil moisture dielectric calibrations one can determine θ of the soil sample. The paper presents simulation results and laboratory tests of an antenna probe. Due to its tough and durable design, this type of probe gives the possibility of easy application in field conditions, which makes it especially suitable for mechanically demanding measurement systems. As the sensitivity zone is comparatively large, this probe is well-suited to measuring soil moisture in the vicinity of the plant root system.