Arkadiusz Lewandowski

Dr. Arkadiusz Lewandowski

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2006 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
DWD.F. Williams
D.F. Williams
ALArkadiusz Lewandowski
Arkadiusz Lewandowski
TCT.S. Clement
T.S. Clement
JWJ.C.M. Wang
J.C.M. Wang
PHP.D. Hale
P.D. Hale
ADA. Dienstfrey
A. Dienstfrey
We develop a covariance matrix describing the uncertainty of mismatch-corrected measurements performed on the National Institute of Standards and Technology's electrooptic sampling system. This formulation offers a general way of describing the uncertainties of the measurement system in both the temporal and frequency domains. We illustrate the utility of the approach with several examples, including determining the uncertainty in the temporal voltage generated by the photodiode

18 December 2014 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
PBPawel Barmuta
Pawel Barmuta
FFFrancesco Ferranti
Francesco Ferranti
GGGian Piero Gibiino
Gian Piero Gibiino
ALArkadiusz Lewandowski
Arkadiusz Lewandowski
Dominique SchreursDominique Schreurs
Dominique Schreurs
This paper presents the response surface methodology in modeling of nonlinear microwave devices. First, different combinations of sampling techniques and types of radial basis functions are evaluated in simulations of the drain current of a 0.15- μm GaAs HEMT transistor described by the Chalmers model. It allows to determine the best settings of the response surface methodology for the modeling of active microwave devices. It is shown that the best sampling strategy is a combination of space-exploration (Voronoi), problem-exploitation (LOLA), and model-error-driven sample rankers. From the various radial basis function models, the fastest convergence is achieved with exponential functions. This knowledge is then used in behavioral modeling of a low-power amplifier AG303 measured in the load-pull setup. It is shown that the response surface methodology outperforms commonly used factorial design of experiments. Moreover, it gives accurate models within just a few tens of samples. However, attention has to be paid at the noisy regions, which might be oversampled by the sampling techniques.

26 May 2009 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
PHPaul D. Hale
Paul D. Hale
ADAndrew Dienstfrey
Andrew Dienstfrey
JWJack C. M. Wang
Jack C. M. Wang
DWDylan F. Williams
Dylan F. Williams
ALArkadiusz Lewandowski
Arkadiusz Lewandowski
TCTracy S. Clement
Tracy S. Clement
We describe a method for calibrating the voltage that a step-like pulse generator produces at a load at every time point in the measured waveform. The calibration includes an equivalent-circuit model of the generator that can be used to determine how the generator behaves when it is connected to arbitrary loads. The generator is calibrated with an equivalent-time sampling oscilloscope and is traceable to fundamental physics via the electro-optic sampling system at the National Institute of Standards and Technology. The calibration includes a covariance-based uncertainty analysis that provides the uncertainty at each time in the waveform vector and the correlations between the uncertainties at the different times. From the calibrated waveform vector and its covariance matrix, we calculate pulse parameters and their uncertainties. We compare our method with a more traditional parameter-based uncertainty analysis.

10 December 2010 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
NONathan D. Orloff
Nathan D. Orloff
JMJordi Mateu
Jordi Mateu
ALArkadiusz Lewandowski
Arkadiusz Lewandowski
EREduard Rocas
Eduard Rocas
JKJosh King
Josh King
JBJames C. Booth
James C. Booth
We present a broadband on-wafer calibration from 45 MHz to 40 GHz for variable temperature measurements, which requires three standards: a thru, reflect, and series resistor. At room temperature, the maximum error of this technique, compared to a benchmark nine-standard multiline thru-reflect-line (TRL) method, is comparable to the repeatability of the benchmark calibration. The series-resistor standard is modeled as a lumped-element -network, which is described by four frequency-independent parameters. We show that the model is stable over three weeks, and compare the calibration to the multiline TRL method as a function of time. The approach is then demonstrated at variable temperature, where the model parameters are extracted at 300 K and at variable temperatures down to 20 K, in order to determine their temperature dependence. The resulting technique, valid over the temperature range from 300 to 20 K, reduced the total footprint of the calibration standards by a factor of 17 and the measurement time by a factor of 3.

22 January 2019 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
ALArkadiusz Lewandowski
Arkadiusz Lewandowski
ASAgnieszka Szypłowska
Agnieszka Szypłowska
AWAndrzej Wilczek
Andrzej Wilczek
MKMarcin Kafarski
Marcin Kafarski
JSJustyna Szerement
Justyna Szerement
WSWojciech Skierucha
Wojciech Skierucha

12 January 2017 in Measurement Science and Technology
Verified
Journal Article
Open access
PDF file
ALArkadiusz Lewandowski
Arkadiusz Lewandowski
ASAgnieszka Szypłowska
Agnieszka Szypłowska
MKMarcin Kafarski
Marcin Kafarski
AWAndrzej Wilczek
Andrzej Wilczek
PBPaweł Barmuta
Paweł Barmuta
WSWojciech Skierucha
Wojciech Skierucha