Vittorio Cristini

Prof. Dr. Vittorio Cristini

Mathematics in Medicine Program, The Houston Methodist Research Institute, Houston, TX, USA
+2

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2018 in Nature Communications
Verified
Journal Article
Open access
PDF file
PDPrashant Dogra
Prashant Dogra
NANatalie L. Adolphi
Natalie L. Adolphi
ZWZhihui Wang
Zhihui Wang
YLYu-Shen Lin
Yu-Shen Lin
KBKimberly S. Butler
Kimberly S. Butler
CBC Jeffrey Brinker
C Jeffrey Brinker
The progress of nanoparticle (NP)-based drug delivery has been hindered by an inability to establish structure-activity relationships in vivo. Here, using stable, monosized, radiolabeled, mesoporous silica nanoparticles (MSNs), we apply an integrated SPECT/CT imaging and mathematical modeling approach to understand the combined effects of MSN size, surface chemistry and routes of administration on biodistribution and clearance kinetics in healthy rats. We show that increased particle size from ~32- to ~142-nm results in a monotonic decrease in systemic bioavailability, irrespective of route of administration, with corresponding accumulation in liver and spleen. Cationic MSNs with surface exposed amines (PEI) have reduced circulation, compared to MSNs of identical size and charge but with shielded amines (QA), due to rapid sequestration into liver and spleen. However, QA show greater total excretion than PEI and their size-matched neutral counterparts (TMS). Overall, we provide important predictive functional correlations to support the rational design of nanomedicines.

28 February 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Hermann FrieboesHermann Frieboes
Hermann Frieboes
MWMin Wu
Min Wu
JLJohn Lowengrub
John Lowengrub
Paolo DecuzziPaolo Decuzzi
Paolo Decuzzi
VCVittorio Cristini
Vittorio Cristini
Vascular targeting of malignant tissues with systemically injected nanoparticles (NPs) holds promise in molecular imaging and anti-angiogenic therapies. Here, a computational model is presented to predict the development of tumor neovasculature over time and the specific, vascular accumulation of blood-borne NPs. A multidimensional tumor-growth model is integrated with a mesoscale formulation for the NP adhesion to blood vessel walls. The fraction of injected NPs depositing within the diseased vasculature and their spatial distribution is computed as a function of tumor stage, from 0 to day 24 post-tumor inception. As the malignant mass grows in size, average blood flow and shear rates increase within the tumor neovasculature, reaching values comparable with those measured in healthy, pre-existing vessels already at 10 days. The NP vascular affinity, interpreted as the likelihood for a blood-borne NP to firmly adhere to the vessel walls, is a fundamental parameter in this analysis and depends on NP size and ligand density, and vascular receptor expression. For high vascular affinities, NPs tend to accumulate mostly at the inlet tumor vessels leaving the inner and outer vasculature depleted of NPs. For low vascular affinities, NPs distribute quite uniformly intra-tumorally but exhibit low accumulation doses. It is shown that an optimal vascular affinity can be identified providing the proper balance between accumulation dose and uniform spatial distribution of the NPs. This balance depends on the stage of tumor development (vascularity and endothelial receptor expression) and the NP properties (size, ligand density and ligand-receptor molecular affinity). Also, it is demonstrated that for insufficiently developed vascular networks, NPs are transported preferentially through the healthy, pre-existing vessels, thus bypassing the tumor mass. The computational tool described here can effectively select an optimal NP formulation presenting high accumulation doses and uniform spatial intra-tumor distributions as a function of the development stage of the malignancy.

1 May 2020 in Science Advances
Verified
Journal Article
Open access
PDF file
JBJoseph D. Butner
Joseph D. Butner
DEDalia Elganainy
Dalia Elganainy
CWCharles X. Wang
Charles X. Wang
ZWZhihui Wang
Zhihui Wang
SCShu-Hsia Chen
Shu-Hsia Chen
VCVittorio Cristini
Vittorio Cristini
We present a mechanistic mathematical model of immune checkpoint inhibitor therapy to address the oncological need for early, broadly applicable readouts (biomarkers) of patient response to immunotherapy. The model is built upon the complex biological and physical interactions between the immune system and cancer, and is informed using only standard-of-care CT. We have retrospectively applied the model to 245 patients from multiple clinical trials treated with anti–CTLA-4 or anti–PD-1/PD-L1 antibodies. We found that model parameters distinctly identified patients with common (n = 18) and rare (n = 10) malignancy types who benefited and did not benefit from these monotherapies with accuracy as high as 88% at first restaging (median 53 days). Further, the parameters successfully differentiated pseudo-progression from true progression, providing previously unidentified insights into the unique biophysical characteristics of pseudo-progression. Our mathematical model offers a clinically relevant tool for personalized oncology and for engineering immunotherapy regimens.

4 January 2021 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
JBJoseph D. Butner
Joseph D. Butner
ZWZhihui Wang
Zhihui Wang
DEDalia Elganainy
Dalia Elganainy
KFKarine A. Al Feghali
Karine A. Al Feghali
MPMarija Plodinec
Marija Plodinec
VCVittorio Cristini
Vittorio Cristini

10 July 2023 in JCI Insight
Verified
Journal Article
Open access
PDF file
PDPrashant Dogra
Prashant Dogra
CSCarmine Schiavone
Carmine Schiavone
ZWZhihui Wang
Zhihui Wang
JRJavier Ruiz Ramírez
Javier Ruiz Ramírez
Sergio CasertaSergio Caserta
Sergio Caserta
VCVittorio Cristini
Vittorio Cristini
While the development of different vaccines slowed the dissemination of SARS-CoV-2, the occurrence of breakthrough infections has continued to fuel the COVID-19 pandemic. To secure at least partial protection in the majority of the population through 1 dose of a COVID-19 vaccine, delayed administration of boosters has been implemented in many countries. However, waning immunity and emergence of new variants of SARS-CoV-2 suggest that such measures may induce breakthrough infections due to intermittent lapses in protection. Optimizing vaccine dosing schedules to ensure prolonged continuity in protection could thus help control the pandemic. We developed a mechanistic model of immune response to vaccines as an in silico tool for dosing schedule optimization. The model was calibrated with clinical data sets of acquired immunity to COVID-19 mRNA vaccines in healthy and immunocompromised participants and showed robust validation by accurately predicting neutralizing antibody kinetics in response to multiple doses of COVID-19 mRNA vaccines. Importantly, by estimating population vulnerability to breakthrough infections, we predicted tailored vaccination dosing schedules to minimize breakthrough infections, especially for immunocompromised individuals. We identified that the optimal vaccination schedules vary from CDC-recommended dosing, suggesting that the model is a valuable tool to optimize vaccine efficacy outcomes during future outbreaks.

21 April 2020 in WIREs Nanomedicine and Nanobiotechnology
Verified
Journal Article
Open access
PDF file
PDPrashant Dogra
Prashant Dogra
JBJoseph D. Butner
Joseph D. Butner
SNSara Nizzero
Sara Nizzero
JRJavier Ruiz Ramírez
Javier Ruiz Ramírez
ANAchraf Noureddine
Achraf Noureddine
ZWZhihui Wang
Zhihui Wang
While plasma concentration kinetics has traditionally been the predictor of drug pharmacological effects, it can occasionally fail to represent kinetics at the site of action, particularly for solid tumors. This is especially true in the case of delivery of therapeutic macromolecules (drug‐loaded nanomaterials or monoclonal antibodies), which can experience challenges to effective delivery due to particle size‐dependent diffusion barriers at the target site. As a result, disparity between therapeutic plasma kinetics and kinetics at the site of action may exist, highlighting the importance of target site concentration kinetics in determining the pharmacodynamic effects of macromolecular therapeutic agents. Assessment of concentration kinetics at the target site has been facilitated by non‐invasive in vivo imaging modalities. This allows for visualization and quantification of the whole‐body disposition behavior of therapeutics that is essential for a comprehensive understanding of their pharmacokinetics and pharmacodynamics. Quantitative non‐invasive imaging can also help guide the development and parameterization of mathematical models for descriptive and predictive purposes. Here, we present a review of the application of state‐of‐the‐art imaging modalities for quantitative pharmacological evaluation of therapeutic nanoparticles and monoclonal antibodies, with a focus on their integration with mathematical models, and identify challenges and opportunities.This article is categorized under: Therapeutic Approaches and Drug Discovery > Nanomedicine for Oncologic Disease Diagnostic Tools > in vivo Nanodiagnostics and Imaging Nanotechnology Approaches to Biology > Nanoscale Systems in Biology