Laimonas Bartusis

Dr. Laimonas Bartusis


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
LSLina Siaudvytyte
Lina Siaudvytyte
Ingrida JanulevicieneIngrida Januleviciene
Ingrida Januleviciene
ARArminas Ragauskas
Arminas Ragauskas
LBLaimonas Bartusis
Laimonas Bartusis
IMIndre Meiliuniene
Indre Meiliuniene
AHAlon Harris
Alon Harris
Purpose. To assess differences in translaminar pressure gradient (TPG) and neuroretinal rim area (NRA) in patients with normal tension glaucoma (NTG), high tension glaucoma (HTG), and healthy controls.Methods. 27 patients with NTG, HTG, and healthy controls were included in the prospective pilot study (each group consisted of 9 patients). Intraocular pressure (IOP), intracranial pressure (ICP), and confocal laser scanning tomography were assessed. TPG was calculated as the difference of IOP minus ICP. ICP was measured using noninvasive two-depth transcranial Doppler device. The level of significanceP< 0.05 was considered significant.Results. NTG patients had significantly lower IOP (13.7(1.6) mmHg), NRA (0.97(0.36) mm2), comparing with HTG and healthy subjects,P< 0.05. ICP was lower in NTG (7.4(2.7) mmHg), compared with HTG (8.9(1.9) mmHg) and healthy subjects (10.5(3.0) mmHg); however, the difference between groups was not statistically significant (P>0.05). The difference between TPG for healthy (5.4(7.7) mmHg) and glaucomatous eyes (NTG 6.3(3.1) mmHg, HTG 15.7(7.7) mmHg) was statistically significant (P< 0.001). Higher TPG was correlated with decreased NRA (r= −0.83;P= 0.01) in the NTG group.Conclusion. Translaminar pressure gradient was higher in glaucoma patients. Reduction of NRA was related to higher TPG in NTG patients. Further prospective studies are warranted to investigate the involvement of TPG in glaucoma management.

14 March 2016 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Closed access
PDF file
LKLars-Owe Daniel Koskinen
Lars-Owe Daniel Koskinen
JMJan Malm
Jan Malm
RZRolandas Zakelis
Rolandas Zakelis
LBLaimonas Bartusis
Laimonas Bartusis
ARArminas Ragauskas
Arminas Ragauskas
AEAnders Eklund
Anders Eklund

30 November 2020 in Medicina
Verified
Journal Article
Open access
PDF file
MDMantas Deimantavicius
Mantas Deimantavicius
YHYasin Hamarat
Yasin Hamarat
PLPaulius Lucinskas
Paulius Lucinskas
RZRolandas Zakelis
Rolandas Zakelis
LBLaimonas Bartusis
Laimonas Bartusis
ARArminas Ragauskas
Arminas Ragauskas
Background and Objective: Glaucoma is a progressive optic neuropathy in which the optic nerve is damaged. The optic nerve is exposed not only to intraocular pressure (IOP) in the eye, but also to intracranial pressure (ICP), as it is surrounded by cerebrospinal fluid in the subarachnoid space. Here, we analyse ICP differences between patients with glaucoma and healthy subjects (HSs). Materials and Methods: Ninety-five patients with normal-tension glaucoma (NTG), 60 patients with high-tension glaucoma (HTG), and 62 HSs were included in the prospective clinical study, and ICP was measured non-invasively by two-depth transcranial Doppler (TCD). Results: The mean ICP of NTG patients (9.42 ± 2.83 mmHg) was significantly lower than that of HSs (10.73 ± 2.16 mmHg) (p = 0.007). The mean ICP of HTG patients (8.11 ± 2.68 mmHg) was significantly lower than that of NTG patients (9.42 ± 2.83 mmHg) (p = 0.008) and significantly lower than that of HSs (10.73 ± 2.16 mmHg) (p < 0.001). Conclusions: An abnormal ICP value could be one of the many influential factors in the optic nerve degeneration of NTG patients and should be considered as such instead of just being regarded as a “low ICP”.

26 February 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PLPaulius Lucinskas
Paulius Lucinskas
MDMantas Deimantavicius
Mantas Deimantavicius
LBLaimonas Bartusis
Laimonas Bartusis
RZRolandas Zakelis
Rolandas Zakelis
EMEdgaras Misiulis
Edgaras Misiulis
YHYasin Hamarat
Yasin Hamarat
Intracranial pressure (ICP) monitoring is important in managing neurosurgical, neurological, and ophthalmological patients with open-angle glaucoma. Non-invasive two-depth transcranial Doppler (TCD) technique is used in a novel method for ICP snapshot measurement that has been previously investigated prospectively, and the results showed clinically acceptable accuracy and precision. The aim of this study was to investigate possibility of using the ophthalmic artery (OA) as a pressure sensor for continuous ICP monitoring. First, numerical modeling was done to investigate the possibility, and then a pilot clinical study was conducted to compare two-depth TCD-based non-invasive ICP monitoring data with readings from an invasive Codman ICP microsensor from patients with severe traumatic brain injury. The numerical modeling showed that the systematic error of non-invasive ICP monitoring was < 1.0 mmHg after eliminating the intraorbital and blood pressure gradient. In a clinical study, a total of 1928 paired data points were collected, and the extreme data points of measured differences between invasive and non-invasive ICP were − 3.94 and 4.68 mmHg (95% CI − 2.55 to 2.72). The total mean and SD were 0.086 ± 1.34 mmHg, and the correlation coefficient was 0.94. The results show that the OA can be used as a linear natural pressure sensor and that it could potentially be possible to monitor the ICP for up to 1 h without recalibration.

1 January 2017 in Libyan Journal of Medicine
Verified
Journal Article
Open access
YHYasin Hamarat
Yasin Hamarat
MDMantas Deimantavicius
Mantas Deimantavicius
EKEvaldas Kalvaitis
Evaldas Kalvaitis
LSLina Siaudvytyte
Lina Siaudvytyte
Ingrida JanulevicieneIngrida Januleviciene
Ingrida Januleviciene
LBLaimonas Bartusis
Laimonas Bartusis
The aim of the present study was to locate the ophthalmic artery by using the edge of the internal carotid artery (ICA) as the reference depth to perform a reliable non-invasive intracranial pressure measurement via a multi-depth transcranial Doppler device and to then determine the positions and angles of an ultrasonic transducer (UT) on the closed eyelid in the case of located segments. High tension glaucoma (HTG) patients and healthy volunteers (HVs) undergoing non-invasive intracranial pressure measurement were selected for this prospective study. The depth of the edge of the ICA was identified, followed by a selection of the depths of the IOA and EOA segments. The positions and angles of the UT on the closed eyelid were measured. The mean depth of the identified ICA edge for HTG patients was 64.3 mm and was 63.0 mm for HVs (p = 0.21). The mean depth of the selected IOA segment for HTG patients was 59.2 mm and 59.3 mm for HVs (p = 0.91). The mean depth of the selected EOA segment for HTG patients was 48.5 mm and 49.8 mm for HVs (p = 0.14). The difference in the located depths of the segments between groups was not statistically significant. The results showed a significant difference in the measured UT angles in the case of the identified edge of the ICA and selected ophthalmic artery segments (p = 0.0002). We demonstrated that locating the IOA and EOA segments can be achieved using the edge of the ICA as a reference point. Abbreviations: OA: ophthalmic artery; IOA: intracranial segments of the ophthalmic artery; EOA: extracranial segments of the ophthalmic artery; ICA: internal carotid artery; UT: ultrasonic transducer; HTG: high tension glaucoma; SD: standard deviation; ICP: intracranial pressure; TCD: transcranial Doppler

3 March 2021 in Medicina
Verified
Journal Article
Open access
PDF file
YHYasin Hamarat
Yasin Hamarat
LBLaimonas Bartusis
Laimonas Bartusis
MDMantas Deimantavicius
Mantas Deimantavicius
PLPaulius Lucinskas
Paulius Lucinskas
LSLina Siaudvytyte
Lina Siaudvytyte
ARArminas Ragauskas
Arminas Ragauskas
Ventriculoperitoneal shunt placement is the most commonly used treatment of normal-pressure hydrocephalus (NPH). It has been hypothesized that normal-tension glaucoma (NTG) is caused by the treatment of NPH by using the shunt to reduce intracranial pressure (ICP). The aim of this study is to review the literature published regarding this hypothesis and to emphasize the need for neuro-ophthalmic follow-up for the concerned patients. The source literature was selected from the results of an online PubMed search, using the keywords “hydrocephalus glaucoma” and “normal-tension glaucoma shunt”. One prospective study on adults, one prospective study on children, two retrospective studies on adults and children, two case reports, three review papers including medical hypotheses, and one prospective study on monkeys were identified. Hypothesis about the association between the treatment of NPH using the shunt to reduce ICP and the development of NTG were supported in all reviewed papers. This suggests that a safe lower limit of ICP for neurological patients, especially shunt-treated NPH patients, should be kept. Thus, we proposed to modify the paradigm of safe upper ICP threshold recommended in neurosurgery and neurology into the paradigm of safe ICP corridor applicable in neurology and ophthalmology, especially for shunt-treated hydrocephalic and glaucoma patients.