Edgaras Misiulis

Dr. Edgaras Misiulis

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Chaos, Solitons & Fractals
Verified
Journal Article
Closed access
ADAlgis Džiugys
Algis Džiugys
MBMartynas Bieliūnas
Martynas Bieliūnas
GSGediminas Skarbalius
Gediminas Skarbalius
EMEdgaras Misiulis
Edgaras Misiulis
RNRobertas Navakas
Robertas Navakas

1 September 2021 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
GSGediminas Skarbalius
Gediminas Skarbalius
ADAlgis Džiugys
Algis Džiugys
EMEdgaras Misiulis
Edgaras Misiulis
RNRobertas Navakas
Robertas Navakas

19 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
GSGediminas Skarbalius
Gediminas Skarbalius
ADAlgis Džiugys
Algis Džiugys
EMEdgaras Misiulis
Edgaras Misiulis
RNRobertas Navakas
Robertas Navakas
PVPaulius Vilkinis
Paulius Vilkinis
NPNerijus Pedišius
Nerijus Pedišius
In the present paper, molecular dynamics simulations were performed to study the influence of two temperature control strategies on water flow behaviour inside planar nanochannel. In the simulations, the flow was induced by the force acting on each water molecule in the channel. Two temperature control strategies were considered: (a) frozen wall simulations, in which the dynamics of confining wall atoms was not solved and the thermostat was applied to the water, and (b) dynamic wall simulations, in which the dynamics of confining wall atoms was solved, and the thermostat was applied to walls while water was simulated in the microcanonical ensemble. The simulation results show that the considered temperature control strategies has no effect on the shape of the water flow profile, and flow behaviour in the channel is well described by the Navier–Stokes equation solution with added slip velocity. Meanwhile, the slip velocity occurring at the boundaries of the channel is linearly dependent on the magnitude of the flow inducing force in both frozen wall and dynamic wall simulations. However, the slip velocity is considerably greater in simulations when the wall dynamics are solved in contrast to the frozen wall simulations.


28 April 2024 in European Journal of Radiology
Verified
Journal Article
Closed access
VRVytenis Ratkunas
Vytenis Ratkunas
EMEdgaras Misiulis
Edgaras Misiulis
ILIndre Lapinskiene
Indre Lapinskiene
GSGediminas Skarbalius
Gediminas Skarbalius
RNRobertas Navakas
Robertas Navakas
VPVytautas Petkus
Vytautas Petkus

26 February 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PLPaulius Lucinskas
Paulius Lucinskas
MDMantas Deimantavicius
Mantas Deimantavicius
LBLaimonas Bartusis
Laimonas Bartusis
RZRolandas Zakelis
Rolandas Zakelis
EMEdgaras Misiulis
Edgaras Misiulis
YHYasin Hamarat
Yasin Hamarat
Intracranial pressure (ICP) monitoring is important in managing neurosurgical, neurological, and ophthalmological patients with open-angle glaucoma. Non-invasive two-depth transcranial Doppler (TCD) technique is used in a novel method for ICP snapshot measurement that has been previously investigated prospectively, and the results showed clinically acceptable accuracy and precision. The aim of this study was to investigate possibility of using the ophthalmic artery (OA) as a pressure sensor for continuous ICP monitoring. First, numerical modeling was done to investigate the possibility, and then a pilot clinical study was conducted to compare two-depth TCD-based non-invasive ICP monitoring data with readings from an invasive Codman ICP microsensor from patients with severe traumatic brain injury. The numerical modeling showed that the systematic error of non-invasive ICP monitoring was < 1.0 mmHg after eliminating the intraorbital and blood pressure gradient. In a clinical study, a total of 1928 paired data points were collected, and the extreme data points of measured differences between invasive and non-invasive ICP were − 3.94 and 4.68 mmHg (95% CI − 2.55 to 2.72). The total mean and SD were 0.086 ± 1.34 mmHg, and the correlation coefficient was 0.94. The results show that the OA can be used as a linear natural pressure sensor and that it could potentially be possible to monitor the ICP for up to 1 h without recalibration.