Yoko Suzuki

Ms. Yoko Suzuki

University of Tsukuba
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2020 in Sensors
Verified
Journal Article
Open access
PDF file
TYToshitaka Yamakawa
Toshitaka Yamakawa
MMMiho Miyajima
Miho Miyajima
KFKoichi Fujiwara
Koichi Fujiwara
MKManabu Kano
Manabu Kano
YSYoko Suzuki
Yoko Suzuki
TMTaketoshi Maehara
Taketoshi Maehara
A warning prior to seizure onset can help improve the quality of life for epilepsy patients. The feasibility of a wearable system for predicting epileptic seizures using anomaly detection based on machine learning is evaluated. An original telemeter is developed for continuous measurement of R-R intervals derived from an electrocardiogram. A bespoke smartphone app calculates the indices of heart rate variability in real time from the R-R intervals, and the indices are monitored using multivariate statistical process control by the smartphone app. The proposed system was evaluated on seven epilepsy patients. The accuracy and reliability of the R-R interval measurement, which was examined in comparison with the reference electrocardiogram, showed sufficient performance for heart rate variability analysis. The results obtained using the proposed system were compared with those obtained using the existing video and electroencephalogram assessments; it was noted that the proposed method has a sensitivity of 85.7% in detecting heart rate variability change prior to seizures. The false positive rate of 0.62 times/h was not significantly different from the healthy controls. The prediction performance and practical advantages of portability and real-time operation are demonstrated in this study.

28 November 2020 in Nutrients
Verified
Journal Article
Open access
PDF file
SZSimeng Zhang
Simeng Zhang
JTJiro Takano
Jiro Takano
NMNorihito Murayama
Norihito Murayama
MTMorie Tominaga
Morie Tominaga
TATakashi Abe
Takashi Abe
Kumpei TokuyamaKumpei Tokuyama
Kumpei Tokuyama
Ingesting oolong tea or caffeine acutely increases energy expenditure, and oolong tea, but not caffeine, stimulates fat oxidation. The acute effects of caffeine, such as increased heart rate and interference with sleep, diminish over 1–4 days, known as caffeine tolerance. During each 14-day session of the present study, 12 non-obese males consumed oolong tea (100 mg caffeine, 21.4 mg gallic acid, 97 mg catechins and 125 mg polymerized polyphenol), caffeine (100 mg), or placebo at breakfast and lunch. On day 14 of each session, 24-h indirect calorimetry and polysomnographic sleep recording were performed. Caffeine and oolong tea increased fat oxidation by ~20% without affecting energy expenditure over 24-h. The decrease in the respiratory quotient by oolong tea was greater than that by caffeine during sleep. The effect of oolong tea on fat oxidation was salient in the post-absorptive state. These findings suggest a role of unidentified ingredients in oolong tea to stimulate fat oxidation, and this effect is partially suppressed in a postprandial state. Two weeks of caffeine or oolong tea ingestion increased fat oxidation without interfering with sleep. The effects of subacute ingestion of caffeine and oolong tea differed from the acute effects, which is a particularly important consideration regarding habitual tea consumption.

7 January 2025 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CSChihiro Suzuki
Chihiro Suzuki
YSYoko Suzuki
Yoko Suzuki
TATakashi Abe
Takashi Abe
TKTakashi Kanbayashi
Takashi Kanbayashi
SFShoji Fukusumi
Shoji Fukusumi
QLQinghua Liu
Qinghua Liu
In remote areas, visiting a laboratory for sleep testing is inconvenient. We, therefore, developed a Mobile Sleep Lab in a bus powered by fuel cells with two sleep measurement chambers. As the environment in the bus could affect sleep, we examined whether sleep testing in the Mobile Sleep Lab was as feasible as in a conventional sleep laboratory (Human Sleep Lab). We tested 15 healthy adults for four nights using polysomnography (the first two nights at the Human Sleep Lab or Mobile Sleep Lab with a switch to the other facility for the next two nights). Sleep variables of the four measurements were used to assess the discrepancy of different places or different nights. No significant differences were found between the laboratories other than the percentage of total sleep time in stage N3. Next, we analyzed the intraclass correlation coefficient to evaluate the test-retest reliability. The intraclass correlation coefficient between these two measurements: the Human Sleep Lab and Mobile Sleep Lab showed similar reliability for the same sleep variables. The intraclass correlation coefficient revealed that several sleep indexes, such as total sleep time, sleep efficiency, wake after sleep onset, percentage of stage N1, and stage R latency, showed poor reliabilities (<0.5) based on Koo and Li’s criteria. In contrast, the percentage of stage N3 showed moderate (0.5–0.75) or good (0.75–0.9) reliabilities. As almost all sleep variables showed no difference and same level of test-retest reliability between the Mobile Sleep Lab and Human Sleep Lab, the Mobile Sleep Lab might be suitable for conducting polysomnography as a conventional sleep laboratory. The reduction in N3 in the Mobile Sleep Lab should be scrutinized in the larger sample, including sleep disorders. Practical application of the Mobile Sleep Lab can transform sleep medicine in remote areas.

6 October 2017 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
YSYoko Suzuki
Yoko Suzuki
MMMiho Miyajima
Miho Miyajima
KOKatsuya Ohta
Katsuya Ohta
NYNoriko Yoshida
Noriko Yoshida
RORie Omoya
Rie Omoya
EMEisuke Matsushima
Eisuke Matsushima

9 November 2018 in Neuropsychopharmacology Reports
Verified
Journal Article
Open access
PDF file
YSYoko Suzuki
Yoko Suzuki
MMMiho Miyajima
Miho Miyajima
KOKatsuya Ohta
Katsuya Ohta
NYNoriko Yoshida
Noriko Yoshida
TWTakafumi Watanabe
Takafumi Watanabe
EMEisuke Matsushima
Eisuke Matsushima
Aim: Although electroencephalogram (EEG) seizure duration and seizure threshold change during a course of electroconvulsive therapy, the mechanisms by which these factors influence heart rate during subsequent electroconvulsive therapy sessions are currently unclear. In the current study, we investigated changes in heart rate during electroconvulsive therapy.Methods: We recorded electroencephalography and electrocardiography during electroconvulsive therapy in 12 patients with major depressive disorder. Baseline heart rate was defined as the mean heart rate in the 30 seconds prior to stimulus onset. The TimeMaxpeak refers to the maximum heart rate after stimulus onset. Time1/2points represent the time points at which the heart rate had decreased to a value midway between the baseline heart rate and the TimeMaxpeak. We examined the relationships between EEG seizure duration, TimeMax, and Time1/2throughout the course of electroconvulsive therapy.Results: Time1/2decreased as the number of electroconvulsive sessions increased. Time1/2was positively correlated with EEG seizure duration.Conclusion: The duration in which electroconvulsive therapy‐induced sympathetic nervous system activation returned halfway to baseline levels gradually shortened during the course of electroconvulsive therapy.