Tubuloglomerular feedback (TGF) has an important role in autoregulation of renal blood flow and glomerular filtration rate (GFR). Because of the characteristics of signal transmission in the feedback loop, the TGF undergoes self-sustained oscillations in single-nephron blood flow, GFR, and tubular pressure and flow. Nephrons interact by exchanging electrical signals conducted electrotonically through cells of the vascular wall, leading to synchronization of the TGF-mediated oscillations. Experimental studies of these interactions have been limited to observations on two or at most three nephrons simultaneously. The interacting nephron fields are likely to be more extensive. We have turned to laser speckle contrast imaging to measure the blood flow dynamics of 50–100 nephrons simultaneously on the renal surface of anesthetized rats. We report the application of this method and describe analytic techniques for extracting the desired data and for examining them for evidence of nephron synchronization. Synchronized TGF oscillations were detected in pairs or triplets of nephrons. The amplitude and the frequency of the oscillations changed with time, as did the patterns of synchronization. Synchronization may take place among nephrons not immediately adjacent on the surface of the kidney.
1 May 2005 in American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
With a model of renal blood flow regulation, we examined consequences of tubuloglomerular feedback (TGF) coupling to the myogenic mechanism via voltage-gated Ca channels. The model reproduces the characteristic oscillations of the two mechanisms and predicts frequency and amplitude modulation of the myogenic oscillation by TGF. Analysis by wavelet transforms of single-nephron blood flow confirms that both amplitude and frequency of the myogenic oscillation are modulated by TGF. We developed a double-wavelet transform technique to estimate modulation frequency. Median value of the ratio of modulation frequency to TGF frequency in measurements from 10 rats was 0.95 for amplitude modulation and 0.97 for frequency modulation, a result consistent with TGF as the modulating signal. The simulation predicted that the modulation was regular, while the experimental data showed much greater variability from one TGF cycle to the next. We used a blood pressure signal recorded by telemetry from a conscious rat as the input to the model. Blood pressure fluctuations induced variability in the modulation records similar to those found in the nephron blood flow results. Frequency and amplitude modulation can provide robust communication between TGF and the myogenic mechanism.
1 November 2007 in American Journal of Physiology-Renal Physiology
We searched for synchronization among autoregulation mechanisms using wavelet transforms applied to tubular pressure recordings in nephron pairs from the surface of rat kidneys. Nephrons have two oscillatory modes in the regulation of their pressures and flows: a faster (100–200 mHz) myogenic mode, and a slower (20–40 mHz) oscillation in tubuloglomerular feedback (TGF). These mechanisms interact; the TGF mode modulates both the amplitude and the frequency of the myogenic mode. Nephrons also communicate with each other using vascular signals triggered by membrane events in arteriolar smooth muscle cells. In addition, the TGF oscillation changes in hypertension to an irregular fluctuation with characteristics of deterministic chaos. The analysis shows that, within single nephrons of normotensive rats, the myogenic mode and TGF are synchronized at discrete frequency ratios, with 5:1 most common. There is no distinct synchronization ratio in spontaneously hypertensive rats (SHR). In normotensive rats, full synchronization of both TGF and myogenic modes is the most probable state for pairs of nephrons originating in a common cortical radial artery. For SHR, full synchronization is less probable; most common in SHR is a state of partial synchronization with entrainment between neighboring nephrons for only one of the modes. Modulation of the myogenic mode by the TGF mode is much stronger in hypertensive than in normotensive rats. Synchronization among nephrons forms the basis for an integrated reaction to blood pressure fluctuations. Reduced synchronization in SHR suggests that the effectiveness of the coordinated response is impaired in hypertension.
The individual functional unit of the kidney (the nephron) displays oscillations in its pressure and flow regulation at two different time scales: fast oscillations associated with a myogenic dynamics of the afferent arteriole, and slower oscillations arising from a delay in the tubuloglomerular feedback. We investigate the intra- and internephron entrainment of the two time scales. In addition to full synchronization, both wavelet analyses of experimental data and numerical simulations reveal a partial entrainment in which neighboring nephrons attain a state of chaotic synchronization with respect to their slow dynamics, but the fast dynamics remain desynchronized.
Biological time series often display complex oscillations with several interacting rhythmic components. Renal autoregulation, for instance, involves at least two separate mechanisms both of which can produce oscillatory variations in the pressures and flows of the individual nephrons. Using double-wavelet analysis we propose a method to examine how the instantaneous frequency and amplitude of a fast mode is modulated by the presence of a slower mode. Our method is applied both to experimental data from normotensive and hypertensive rats showing different oscillatory patterns and to simulation results obtained from a physiologically based model of the nephron pressure and flow control. We reveal a nonlinear interaction between the two mechanisms that regulate the renal blood flow in the form of frequency and amplitude modulation of the myogenic oscillations.