Ricardo Picón

Dr. Ricardo Picón

Assoc. Professor

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2021 in Journal of the Brazilian Society of Mechanical Sciences and Engineering
Verified
Journal Article
Closed access
PDF file
DTDaniel Victor da Cunha Teles
Daniel Victor da Cunha Teles
RCRafael Nunes da Cunha
Rafael Nunes da Cunha
DADavid Leonardo Nascimento de Figueiredo Amorim
David Leonardo Nascimento de Figueiredo Amorim
Ricardo PicónRicardo Picón
Ricardo Picón
JLJulio Flórez López
Julio Flórez López

30 November 2020 in Metals
Verified
Journal Article
Open access
PDF file
ENEduardo Nuñez
Eduardo Nuñez
NBNwar Boainy
Nwar Boainy
Freddy GonzalezFreddy Gonzalez
Freddy Gonzalez
RTRonald Torres
Ronald Torres
Ricardo PicónRicardo Picón
Ricardo Picón
NGNestor Luis Guerrero
Nestor Luis Guerrero
Steel buildings with tubular columns showed a satisfactory performance during the Honshu (2011) earthquake, unlike steel buildings in the 1994 Northridge and 1995 Kobe earthquakes, where welded moment connections showed damage in their joints. In this research, a lateral joint using a hollow structural section (HSS)-beam and HSS-column subjected to cyclic displacement was performed. Three large-scale specimens were tested and a numerical model was calibrated, reaching a good adjustment. Later, several configurations of beams and columns were evaluated using finite element (FE) models from the numerical model previously calibrated. A flexural resistance higher 0.80 Mp at 0.04 [rad] was obtained for all cases studied. The ductility factor in the 3 specimens was lower than 2.5, therefore a non-ductile behavior was controlled in the connection. This aspect is very important although a 0.8 Mp at 0.04 [rad] was achieved. Finally, the typical welded moment connection can be improved using the bolted moment connection, which allows the concentration of inelastic incursion in the beam compared with the welded solution. However, a non-ductile behavior derived from local buckling in flanges of a tubular beam can affect the seismic performance.

15 May 2024 in Journal of the Brazilian Society of Mechanical Sciences and Engineering
Verified
Journal Article
Closed access
PDF file
DADavid Leonardo Nascimento de Figueiredo Amorim
David Leonardo Nascimento de Figueiredo Amorim
Ricardo PicónRicardo Picón
Ricardo Picón
CVCamila de Sousa Vieira
Camila de Sousa Vieira
JFJulio Flórez-López
Julio Flórez-López

28 February 2024 in Journal of Building Engineering
Verified
Journal Article
Closed access
ZPZhelei Pan
Zhelei Pan
YBYongtao Bai
Yongtao Bai
SMScarlet Karina Montilla
Scarlet Karina Montilla
Ricardo PicónRicardo Picón
Ricardo Picón
CBCarlos Alberto Caldeira Brant
Carlos Alberto Caldeira Brant
JLJulio Flórez López
Julio Flórez López

1 October 2020 in Informes de la Construcción
Verified
Journal Article
Open access
JTJesús Alberto Torres
Jesús Alberto Torres
RTRoberto José Torres
Roberto José Torres
JPJackeline Coromoto Peña
Jackeline Coromoto Peña
Ricardo PicónRicardo Picón
Ricardo Picón
LMLuiggi Méndez
Luiggi Méndez
RCRuben José Calderas
Ruben José Calderas
An experimental study of the mechanical behavior of the Vetiver grass root system is shown in this paper. Experimental tests of tensile strength (305) were carried out in the primary root system of the Vetiver plant, sown in different soils and different growth states. The methodology starts from the reproduction of the plant and its care in the different types of soil where they were planted. The method proposed by Mickovski and Van Beek was used to prepare experimental tests (1). The results obtained reflect a substantial increase in its tensile strength compared to the strength taken usually for the stabilization designs (75 MPa). The maximum load is increased according to the diameter of the root in a potential relationship, and the traction stress of the Vetiver plant root reaches a mean and moda of 118.5 MPa and 131.71 MPa, respectively.

31 May 2024 in Revista Politécnica
Verified
Journal Article
Open access
PDF file
RTRoberto Torres-Hoyer
Roberto Torres-Hoyer
JPJackeline Peña
Jackeline Peña
FMFernanda Millalén
Fernanda Millalén
Ricardo PicónRicardo Picón
Ricardo Picón
WBWilmer Barreto
Wilmer Barreto
JTJesús Torres-Hoyer
Jesús Torres-Hoyer
La sub-base del pavimento requiere materiales adecuados para el soporte necesario. Tradicionalmente, se ha utilizado material de préstamo, lo que genera un impacto ambiental. Este estudio analizó el potencial de reutilizar cenizas de desecho industrial depositadas en vertederos. Se realizaron ensayos de laboratorio mezclando el suelo con diferentes proporciones de cenizas. Se determinó la relación entre humedad y peso seco del suelo, se realizó el ensayo C.B.R. (California Bearing Ratio) y se calculó el espesor de pavimentos, con un mismo espesor de sub-base. A medida que aumenta el porcentaje de cenizas, la calidad del suelo disminuye, pero sigue cumpliendo los requisitos para ser utilizado como sub-base. Se recomienda considerar las cenizas de desecho industrial como un material de reciclaje viable en la construcción de pavimentos, lo que reduciría el impacto ambiental asociado a su disposición en vertederos. The pavement sub-base requires suitable materials for the necessary support. Traditionally, borrow material has been used, this generates environmental impact. This study analyzed the potential for reusing industrial waste ashes deposited in landfills. Laboratory tests were conducted by mixing the soil with different proportions of ashes. The relationship between soil moisture and dry weight was determined, and the C.B.R. (California Bearing Ratio) test was performed. The pavement thickness was calculated, keeping the same sub-base thickness. As the percentage of ashes increased, the soil quality decreased, but it still met the requirements for use as a sub-base. It is recommended to consider industrial waste ashes as a viable recycling material in pavement construction, which would reduce the environmental impact associated with their disposal in landfills.